Literature DB >> 31846039

Feasibility study on a novel tiny dosimeter using a barium titanate capacitor.

Yuma Kuga1, Ryo Ogawara2, Masayori Ishikawa3.   

Abstract

In our laboratory we have confirmed that the capacitance of barium titanate-based capacitors changes due to radiation. Since a commercially available capacitor is very small and inexpensive, it may be used as a multidimensional dose meter in which a large number of capacitor elements are arranged, or may be embedded in the body and used as an in-vivo dose meter. In this study we examined the usefulness of a dosimeter using the capacitance change of a barium titanate capacitor. As a basic property, it was confirmed that the dose linearity was good. With regard to dose rate characteristics and response to fractionated irradiation, capacitance change due to aging affects measurement accuracy, but online measurement of capacitance change immediately before irradiation can be performed to correct aging effects during irradiation. By doing this, we confirmed that the dose rate characteristics and the response to fractionated radiation are improved.
© The Author(s) 2019. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.

Entities:  

Keywords:  Barium Titanate capacitor; array dosimeter; in-vivo dosimeter; tiny dosimeter

Year:  2020        PMID: 31846039      PMCID: PMC6976862          DOI: 10.1093/jrr/rrz083

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  3 in total

1.  Capacitance-Based Dosimetry of Co-60 Radiation using Fully-Depleted Silicon-on-Insulator Devices.

Authors:  Yulong Li; Warren M Porter; Rui Ma; Margaret A Reynolds; Bruce J Gerbi; Steven J Koester
Journal:  IEEE Trans Nucl Sci       Date:  2015-11-09       Impact factor: 1.679

2.  Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer.

Authors:  M J Zelefsky; Z Fuks; L Happersett; H J Lee; C C Ling; C M Burman; M Hunt; T Wolfe; E S Venkatraman; A Jackson; M Skwarchuk; S A Leibel
Journal:  Radiother Oncol       Date:  2000-06       Impact factor: 6.280

3.  Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays.

Authors:  Steffi Kantz; Almut Troeller McDermott; Matthias Söhn; Sabine Reinhardt; Claus Belka; Katia Parodi; Michael Reiner
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.