| Literature DB >> 27826382 |
Bulem Yuzugullu1, Ozlem Acar1, Cem Cetinsahin1, Cigdem Celik2.
Abstract
PURPOSE: The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth.Entities:
Keywords: Complete denture; Denture cleansers; Mechanical properties; Physical properties; Sodium hypochlorite; Sodium perborate
Year: 2016 PMID: 27826382 PMCID: PMC5099124 DOI: 10.4047/jap.2016.8.5.333
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Artificial teeth and denture cleansers used in this study
| Tooth Type and denture cleansers | Composition | Manufacturer | Lot number |
|---|---|---|---|
| SR Orthotyp PE | Unfilled PMMA | Ivoclar Vivadent, AG FL-9494 Schaan, Liechtenstein | SP1496 |
| SR Orthosit PE | Microfilled resin composite (Isosit + inorganic fillers) UDMA | Ivoclar Vivadent, AG FL-9494 Schaan, Liechtenstein | SP1494 |
| SR Postaris DCL | DCL-PMMA/UDMA with 20% prepolymerized PMMA | Ivoclar Vivadent, AG FL-9494 Schaan, Liechtenstein | RP0304 |
| SR Phonares II | NHC (UDMA + fillers + PMMA cluster) | Ivoclar Vivadent, AG FL-9494 Schaan, Liechtenstein | SP1018 |
| Corega Tabs | Sodium bicarbonate, citric acid, potassium caroate (potassium monopersulphate), sodium carbonate, sodium carbonate peroxite, TAED, sodium benzoate, PEG-180, sodium laurile sulphoacetate, PVP/VA copolymer, aroma, subtilisin, Cl42090, Cl73015 | Stafford-Miller Limited, Clocherane, Youghal Road, Dungarvan, Co. | 3T14134A |
| NaOCl | Sodium hypochlorite solution 1% active chlorine | Aklar Kimya, Ankara, Turkey |
PMMA: polymethyl methacrylate; DCL: polymer double cross-linked; UDMA: urethane dimethacrylate; NHC: nanohybrid composite
Median (interquartile range) surface roughness (Ra in µm) values according to artificial teeth and denture cleanser
| SR Orthotyp PE | SR Orthosit PE | SR Postaris DLC | SR Phonares II | ||
|---|---|---|---|---|---|
| Distilled water | 0.07 (0.04)A,B,a | 0.10 (0.03)A,C | 0.09 (0.03)D | 0.13 (0.04)B,C,D | < .001 |
| Corega Tabs | 0.10 (0.03)B,b | 0.09 (0.03)C | 0.09 (0.03)D | 0.13 (0.03)B,C,D | < .001 |
| NaOCl | 0.16 (0.06)A,E,a,b | 0.11 (0.03)A,C | 0.11 (0.02)D,E | 0.13 (0.03)C,D | < .001 |
| < .001 | .132 | .096 | .906 |
*Same superscript letters denote statistical significance (P < .05)
A: There are statistically significant differences between SR Orthotyp PE and SR Orthosit PE groups (P < .017)
B: There are statistically significant differences between SR Orthotyp PE and SR Phonares II groups (P < .001)
C: There are statistically significant differences between SR Orthosit PE and SR Phonares II groups (P < .01)
D: There are statistically significant differences between SR Postaris DLC and SR Phonares II groups (P < .017)
E: There are statistically significant differences between SR Orthotyp PE and SR Postaris DLC groups (P < .001)
a: There are significant differences between distilled water and NaOCl groups (P < .001)
b: There are significant differences between Corega Tabs and NaOCl groups (P < .001)
Median (interquartile range) VHN values according to artificial teeth and denture cleansers
| SR Orthotyp PE | SR Orthosit PE | SR Postaris DLC | SR Phonares II | ||
|---|---|---|---|---|---|
| Distilled water | 26.15 (4.05)A,a | 33.85 (2.22)A,B,C,a,c | 25.75 (3.47)B,a | 27.80 (5.85)C | <.001 |
| Corega Tabs | 32.45 (2.80)A,D,E,a,b | 23.70 (1.97)A,C,a,b | 23.55 (2.35)D,F,a,b | 26.25 (2.90)C,E,F | <.001 |
| NaOCl | 28.75 (10.27)b | 28.20 (3.65)b,c | 25.75 (1.60)b | 27.85 (3.12) | .049 |
| .005 | <.001 | .003 | .582 |
*Same superscript letters denote statistical significance (P < .05)
A: There are statistically significant differences between SR Orthotyp PE and SR Orthosit PE groups (P < .001)
B: There are statistically significant differences between SR Orthosit PE and SR Postaris DLC groups (P < .001)
C: There are statistically significant differences between SR Orthosit PE and SR Phonares II groups (P < .017)
D: There are statistically significant differences between SR Orthotyp PE and SR Postaris DLC groups (P < .001)
E: There are statistically significant differences between SR Phonares II and SR Orthotyp PE groups (P = .002)
F: There are statistically significant differences between SR Postaris DLC and SR Phonares II groups (P = .004)
a: There are significant differences between distilled water and Corega tabs groups (P < .001)
b: There are significant differences between Corega Tabs and NaOCl groups (P < .001)
c: There are significant differences between Distilled water and NaOCl groups (P < .002)