The Brazilian version of the Constant-Murley Score (CMS-BR): convergent and construct validity, internal consistency, and unidimensionality.

Rodrigo Py Gonçalves Barreto1, Marcus Levi Lopes Barbosa2, Marcos Alencar Abaide Balbinotti3, Fernando Carlos Mothes4, Luís Henrique Telles da Rosa1, Marcelo Faria Silva1.   

Abstract

OBJECTIVES: To translate and culturally adapt the CMS and assess the validity of the Brazilian version (CMS-BR).
METHODS: The translation was carried out according to the back-translation method by four independent translators. The produced versions were synthesized through extensive analysis and by consensus of an expert committee, reaching a final version used for the cultural adaptation. A field test was conducted with 30 subjects in order to obtain semantic considerations. For the psychometric analyzes, the sample was increased to 110 participants who answered two instruments: CMS-BR and the Disabilities of the Arm, shoulder and Hand (DASH). The CMS-BR and DASH score range from 0 to 100 points. For the first, higher points reflect better function and for the latter, the inverse is true. The validity was verified by Pearson's correlation test, the unidimensionality by factorial analysis, and the internal consistency by Cronbach's alpha.
RESULTS: The explained variance was 60.28% with factor loadings ranging from 0.60 to 0.91. The CMS-BR exhibited strong negative correlation with the DASH score (-0.82, p < 0.05), Cronbach's alpha 0.85, and its total score was strongly correlated with the patient's range of motion (0.93, p < 0.001).
CONCLUSION: The CMS was satisfactorily adapted for Brazilian Portuguese and demonstrated evidence of validity that allows its use in this population.

Entities:  

Keywords:  Assessment; Clinimetrics; Factor analysis; Shoulder; Validity

Year:  2016        PMID: 27818971      PMCID: PMC5091089          DOI: 10.1016/j.rboe.2016.08.017

Source DB:  PubMed          Journal:  Rev Bras Ortop        ISSN: 2255-4971


Introduction

Shoulder pain accounts for an expressive prevalence in consultations with a general practitioner or orthopedic surgeons.1, 2 These patients often present various complaints, like mobility deficits and pain, which directly affect upper limb function. In order to perform an as comprehensive clinical assessment as possible is recommended that patient be assessed with instruments that allow inferences about function. The function is a construct, a latent variable that cannot be directly observed. Therefore, the utilization of functional scores is the adequate option to measure it.4, 5 There are about 34 scores for shoulder function assessment but the Constant–Murley score (CMS), originally published in the English language, is one of the most used.4, 6, 7 The CMS is a non-specific score that covers different domains of shoulder function (pain, activities of daily living, range of motion and power) being higher scores indicative of better function.6, 7, 8 This instrument is a compound score containing four subscales: three self-reported subscales and one shoulder elevation strength subscale which is performed by an external assessor. The nomenclature of the “power” subscale contained in the original version of the CMS was posteriorly changed to “strength”, as well as the test position was changed to elevation in scapular plane. The appropriate use of an instrument of evaluation implies the correct verification of its validity.10, 11 The evidence of validity characterize the relationship among items of the score and between items and total score. It also indicates the extent in which the instrument explains the construct under assessment. This process ensures an adequate representation of the construct measured by the functional score.12, 13 Psychometric properties of the original version of the CMS such as reliability, floor and ceiling effects, convergent and criterion validity have been verified. Despite the comprehensive investigation of the validity of the score, its dimensional structure was investigated before the adaptation of the strength subscale and the factor analysis evinced that the score was not unidimensional. These aforementioned features could affect the interpretation of measurement of the construct.5, 12, 15 The use of an instrument of evaluation in another culture or language must be preceded by an appropriate process of translation and cultural adaptation. Furthermore, evidence of validity must be properly verified in the adapted version. Currently, a translated and adapted version of CMS is available only for the Danish16, 17 language. There is no version of CMS in the Brazilian Portuguese language. Therefore, the aim of this study was translate, culturally adapt and verify the convergent and construct validity, internal consistency and dimensional structure of the adapted version.

Methods

The process of translation was performed according the back-translation method10, 11 and following the COSMIN checklist for ensure the methodological quality of the psychometric analysis. The recommendations published by Constant et al. were followed, excepting for the branding and model of the dynamometer. In this study an isometric dynamometer model MicroFET2™ (Hoggan Health Industries, USA) with a sensitivity of 0.05 kg (0.1 lb), measuring up to 136.05 kg (300 lb) was utilized in the strength subscale.

Translation and cultural adaption

The process of translation occurred in four steps: translation, back translation, analysis of preliminary version and field test. Initially, two expert and independent Brazilian Portuguese native language translators provided two translated versions of the original CMS. These versions were unified for a consensus between authors and translators. Afterward, the unified translated version was back-translated by two expert and independent English native language translators. Both translators had no access to the original CMS. These versions were unified by consensus of the authors group. The next step involved the establishment of a fully culturally adapted version taking account all existent versions obtained from the previous steps through a multidisciplinary experts committee meeting. Finally, in order to collect semantic considerations, the Brazilian Language version of CMS (CMS-BR) was applied in a sample of 30 subjects with similar characteristics of the main study.

Participants

The participants were selected from private practice clinics of Porto Alegre and Novo Hamburgo, Brazil. This study received approval from the Research Ethics Committee of the proponent institution (study number 992-12) and all participants signed written informed consent prior to the enrollment. A hundred and ten patients (55 male) older than 18 years old, with any diagnoses of clinical shoulder dysfunction (except instability) and able to read and answer to the questionnaire were included. Patients with cognitive impairments, peripheral or central nerve damage or diagnose of nerve dysfunction were excluded of the study. The mean age of the included individuals was 48.50 (15.13) and ranged between 18 and 83 years.

Statistical analysis

A descriptive analysis of all variables was performed. Categorical data were expressed as absolute or relative frequencies and quantitative variables as means and standard deviations.

Clinimetric analysis

Evidence of validity was analyzed through the following statements5, 12, 18, 19: For internal consistency, Cronbach's alpha test considered the value >0.80 as ideal.20, 21 The convergent validity was verified through Pearson's correlation between the total scores of the CMS-BR and the Brazilian version of the Disabilities of the arm, shoulder and hand score (DASH) adopting a r ≥ 0.70 and a p ≤ 0.05 to satisfy this condition.12, 18 The construct validity was verified by the Pearson correlation test between the range of motion of all subjects and the CMS-BR final score. The hypothesis was that the poor functional status would be associated with a less active range of motion in the assessed shoulder. Since the CMS-BR presupposes the assessment of only one construct (shoulder function) and one factor extraction was indicated as the better solution through scree plot and the total explained variance (eigenvalue), a factor analysis with an exploratory principal component analysis with a one-factor solution was performed to verify the dimensional structure. Finally, this analysis considered some assumptions and related tests previous to its realization15, 19: The Kaiser–Meyer–Olkin (KMO) coefficient must be >0.70; The determinant of the correlation matrix must not be zero, but a value closest to zero; Barlett's sphericity test must have a p ≤ 0.05; The communality value must be ≥0.4.23, 24

Results

The list of conditions of all included individuals can be observed in Table 1. The CMS-BR was obtained through adequate translation process following recommendations of the literature. Only one modification was made in the activities of daily living subscale to improve the understanding of the CMS-BR. Specifically, in the last question about which is the arm elevation level without pain, the expression “up to xiphoid” was replaced by “up to heart level” (“ao nível do coração” in Brazilian Portuguese) as can be observed in Appendix 1.
Table 1

List of conditions.

ConditionsAbsolute frequencyRelative frequency
OA AC43.64%
OA GH10.91%
Adhesive capsulitis1513.64%
SIS2623.64%
Proximal fracture of humerus98.18%
ACD21.82%
RCT2220.00%
Bursectomy plus Acromioplasty21.82%
Rotator cuff repair1614.55%
Calcific tendinitis32.73%
Suprascapular nerve release10.91%
Healthy98.18%
Total110100%

AC, acromioclavicular joint; OA, osteoarthritis; GH, glenohumeral joint; SIS, subacromial impingement syndrome; ACD, acromioclavicular joint dislocation; RCT, rotator cuff tear.

Regarding internal consistency, a moderate to strong correlation was observed in each item-total correlation. The mean CMS-BR score was 49.69 (28.12) and the Cronbach's alpha was 0.85. The alpha did not significantly increase with the hypothetical exclusion of any item, confirming the score arrangement of items. Moreover, there was no floor and ceiling effects, when more than 15% of the respondents achieves the highest or lowest possible scores (Table 2).
Table 2

Item-total statistics.

ItemMinMaxMean (SD)Item-total correlationAlpha if item deleted
Pain0158.46 (4.37)0.490.84
Sleep020.88 (0.73)0.630.85
Work042.56 (1.42)0.570.85
Leisure042.26 (1.45)0.610.84
Level of elevation2105.98 (2.84)0.800.82
Flexion0105.24 (3.50)0.830.81
Abduction0104.91 (3.36)0.860.81
External rotation0105.53 (3.81)0.740.82
Internal rotation0105.55 (3.61)0.690.82
Strength0358.32 (10.04)0.750.88

SD, standard deviation. Recommended Cronbach's Alpha: ≥0.80.

The CMS-BR and Brazilian DASH presented a significantly strong negative correlation (r = −0.82, p ≤ 0.001). The direction of this association is due DASH scoring system which higher score is indicative of poor shoulder function conversely to CMS-BR. Moreover, the CMS-BR and the range of motion of the participants were strongly related (r = 0.93, p ≤ 0.001), confirming the a priori hypothesis that poor functional status is related to less active range of motion. The dimensional structure of the CMS-BR was tested by factor analysis with an exploratory principal component analysis with one-factor solution. All assumptions for the test realization were fulfilled. The explained variance by one-factor extraction was 60.28%. The communalities ranged from 0.36 (pain) to 0.83 (Table 3).
Table 3

Communalities and factorial loads of items.

ItemCommunalitiesFactorial load
Abduction0.830.91
Flexion0.800.89
Level of elevation0.740.86
Strength0.650.80
External rotation0.650.80
Internal rotation0.570.75
Leisure0.490.70
Sleep0.470.68
Work0.440.66
Pain0.360.60

Recommended value for communality: ≥0.40.

Discussion

This was the first study to translate and culturally adapt the CMS to Brazilian Portuguese. The preliminary version of CMS-BR was extensively analyzed by physicians, orthopedic-trauma residents, physical therapists, a nurse and a statistician, comprising nine professionals with different backgrounds and was applied in 30 patients. Moreover, important evidences of validity were tested in the CMS-BR such as internal consistency, convergent validity and dimensional structure. The analysis showed that the CMS-BR presented a high internal consistency (Cronbach's alpha = 0.85). The alpha did not increase with the hypothetical exclusion of any item confirming the layout of the adapted score. Interestingly, the internal consistency of the original CMS ranged from 0.60 to 0.75.25, 26 A systematic review suggested that the low alpha values may indicate that the CMS items measure different aspects of shoulder function. To date, there is no objective data to explain the marked observed differences in the alpha values between the CMS and CMS-BR. However, the modifications proposed in 2008 might play a role on it. Furthermore, a moderate to strong correlation was observed in each item-total correlation (Table 2). Regarding convergent validity, the CMS-BR demonstrated a strong negative correlation (r = −0.82, p ≤ 0.001) with the Brazilian version of the DASH score, although the CMS presented a low to moderate association with DASH. The construct validity was confirmed through the significantly strong correlation (r = 0.93, p ≤ 0.001) between CMS-BR score and range of motion. The hypothesis raised by the authors seems totally appropriated since the range of motion is an important characteristic for the shoulder joint and frequently impaired in the majority of shoulder dysfunctions. The Danish version of the CMS also demonstrated a strong correlation with the Oxford Shoulder Score (r = 0.76). In spite of the similar values found in both adapted versions, our reference standard score was the Brazilian DASH – a widely used in myriad of shoulder conditions – while the Oxford Shoulder Score is more suited to assess surgical populations and proximal humerus fractures.6, 28 The factor analysis of the CMS-BR evinced that the amount of variance explained by one-factor solution was 60.28%, ensuring that the CMS-BR met the one-dimensionality criterion. In the original CMS, the factor analysis with a two-factor solution was performed by only one study. However, the authors did not report neither the factor loads nor the adopted criterion to analysis. According to our impression, possibly the lack of standardization, mainly in the pain or strength subscales, could justify these discrepancies in the dimensional structure. A standardized process of implementation was adopted for the realization of our study further the recommendations aforementioned. Other psychometric properties were published about the original CMS. Floor and ceiling effects were analyzed and the strength subscale reported a considerable floor effect. Many patients were unable to hold the proper position for strength assessment receiving zero points. The same report was observed in another study that assessed patients with adhesive capsulitis. Although the strength subscale account for 25% of total score, this not seemed to interfere in the reliability for pain and strength subscales.25, 31 Recently, the minimally important change was verified to patients with subacromial pain. Even that in the present study some properties have not been analyzed, the CMS-BR have satisfactory tested four important attributes of validity and figure among the Brazilian adapted scores with more psychometrics verifications. Puga et al. performed a systematic review which analyzed psychometric properties of all published scores adapted to Brazilian Portuguese until 2011. Of concern is the fact that all included studies in this review did not analyze more than one attribute of validity, which hampers clinical and research usefulness of these instruments. Conversely, the psychometric properties of the Brazilian version of the Penn Shoulder Score were recently verified. The authors reported a comprehensive analysis of the psychometric properties of this instrument, such as internal consistency, measurement error, construct validity and floor and ceiling effects. Furthermore, Moser et al. analyzed internal consistency, convergent validity and reliability of the Brazilian version of the American Shoulder and Elbow Surgeons (ASES) score. Adequate results that support the utilization of both scores were observed. Neto et al. performed the translation and cultural adaptation of the Simple Shoulder Test for Brazilian Portuguese (SST-BR). However, some methodological issues must be considered. In the preliminary version analysis, the expert committee was composed for one physician and six translators. Actually, current recommendations suggest that the expert committee must be composed by different professionals, in order to provide an as complete as possible adapted version to the target population.10, 11 The authors also performed the dimensional structure verification of the SST-BR. However, an exploratory and a subsequent confirmatory factor analysis were performed with a three-factor solution in opposition to the original measurement concept of the score. Our study exhibits some limitations. The verification of reproducibility (agreement and reliability), responsiveness, minimum detectable change and minimally important change were not performed. Nonetheless, firstly is important ensure that the score really measures the target construct (function), and after to analyze more validity properties.

Conclusion

From the results aforementioned it was evinced that the CMS-BR was satisfactory adapted to Brazilian Portuguese culture. Moreover, the CMS-BR has adequate convergent and construct validity, internal consistency and adequate dimensional structure that support its utilization in clinical practice for the evaluation of patients with shoulder dysfunctions.

Conflicts of interest

The authors declare no conflicts of interest.
  31 in total

1.  Validity and reliability of the Portuguese version of the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form.

Authors:  Auristela Duarte de Lima Moser; Luiz Alberto Manfre Knaut; Talita Gnoato Zotz; Karoleen Oswald Scharan
Journal:  Rev Bras Reumatol       Date:  2012 May-Jun

Review 2.  [Shoulder disability questionnaires: a systematic review].

Authors:  F Fayad; Y Mace; M M Lefevre-Colau
Journal:  Ann Readapt Med Phys       Date:  2005-04-26

Review 3.  Assessment of cross-cultural adaptations and measurement properties of self-report outcome measures relevant to shoulder disability in Portuguese: a systematic review.

Authors:  Vanessa O O Puga; Alexandre D Lopes; Leonardo O P Costa
Journal:  Rev Bras Fisioter       Date:  2012-04-03

4.  Standardised test protocol (Constant Score) for evaluation of functionality in patients with shoulder disorders.

Authors:  Ilija Ban; Anders Troelsen; David Høyrup Christiansen; Susanne Wulff Svendsen; Morten Tange Kristensen
Journal:  Dan Med J       Date:  2013-04       Impact factor: 1.240

5.  Convergent validity of the constant-murley outcome measure in patients with rotator cuff disease.

Authors:  Helen Razmjou; Andrea Bean; Joy C Macdermid; Varda van Osnabrugge; Niki Travers; Richard Holtby
Journal:  Physiother Can       Date:  2008-04-15       Impact factor: 1.037

Review 6.  Cross-cultural adaptation of health-related quality of life measures: literature review and proposed guidelines.

Authors:  F Guillemin; C Bombardier; D Beaton
Journal:  J Clin Epidemiol       Date:  1993-12       Impact factor: 6.437

7.  [Intra- and interobserver reproducibility of the French version of the Constant-Murley shoulder assessment during rehabilitation after rotator cuff surgery].

Authors:  T Livain; H Pichon; J Vermeulen; J Vaillant; D Saragaglia; M-F Poisson; S Monnet
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2007-04

Review 8.  Measurement properties of patient-specific instruments measuring physical function.

Authors:  J A Barten; M F Pisters; P A Huisman; T Takken; C Veenhof
Journal:  J Clin Epidemiol       Date:  2012-03-27       Impact factor: 6.437

9.  Translation into Brazilian Portuguese, cultural adaptation and evaluation of the reliability of the Disabilities of the Arm, Shoulder and Hand Questionnaire.

Authors:  A G Orfale; P M P Araújo; M B Ferraz; J Natour
Journal:  Braz J Med Biol Res       Date:  2005-02-15       Impact factor: 2.590

Review 10.  Current concepts in validity and reliability for psychometric instruments: theory and application.

Authors:  David A Cook; Thomas J Beckman
Journal:  Am J Med       Date:  2006-02       Impact factor: 4.965

View more
  9 in total

1.  Arthroscopic Repair of Rotator Cuff Injury: An Analysis of Function, Muscular Strength and Pain Between Single Row and Double Row Techniques.

Authors:  Thiago Medeiros Storti; Thiago da Silva Ribeiro; Rafael Salomon Silva Faria; João Eduardo Simionatto; Carolina Simionatto; Alexandre Firmino Paniago
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2022-01-21

Review 2.  Outcome assessment in the treatment of rotator cuff tear: what is utilized in Brazil?

Authors:  Jorge Henrique Assunção; Eduardo Angeli Malavolta; Vitor Rodrigues Domingues; Mauro Emilio Conforto Gracitelli; Arnaldo Amado Ferreira Neto
Journal:  Rev Bras Ortop       Date:  2017-09-01

3.  Chinese version of the Constant-Murley questionnaire for shoulder pain and disability: a reliability and validation study.

Authors:  Min Yao; Long Yang; Zuo-Yuan Cao; Shao-Dan Cheng; Shuang-Lin Tian; Yue-Li Sun; Jing Wang; Bao-Ping Xu; Xiao-Chun Hu; Yong-Jun Wang; Ying Zhang; Xue-Jun Cui
Journal:  Health Qual Life Outcomes       Date:  2017-09-18       Impact factor: 3.186

4.  Clinical outcomes and cost-utility of rotator cuff repair surgery by open and arthroscopic techniques: study protocol for a randomised clinical trial.

Authors:  Rafael Pierami; Eliane Antonioli; Isadora Oliveira; Isabela Queirós Castro; Felipe Manente; Paula Fairbanks; Eduardo da Frota Carrera; Bruno Akio Matsumura; Mario Lenza
Journal:  BMJ Open       Date:  2020-12-28       Impact factor: 2.692

5.  Shoulder pain across more movements is not related to more rotator cuff tendon findings in people with chronic shoulder pain diagnosed with subacromial pain syndrome.

Authors:  Rafael Krasic Alaiti; J P Caneiro; Juliana T Gasparin; Thais Cristina Chaves; Eduardo A Malavolta; Mauro E C Gracitelli; Ann Meulders; Marcelo Fernandes da Costa
Journal:  Pain Rep       Date:  2021-12-16

6.  HYLAN G-F 20 VERSUS TRIAMCINOLONE IN THE TREATMENT OF PRIMARY SHOULDER OSTEOARTHRITIS. RANDOMIZED TRIAL.

Authors:  Simone Tortato; Alberto DE Castro Pochini; Carlos Vicente Andreoli; Carina Cohen; Paulo Henrique Schmidt Lara; Paulo Santoro Belangero; Benno Ejnisman
Journal:  Acta Ortop Bras       Date:  2022-01-28       Impact factor: 0.513

7.  Arthroscopic Treatment of Rotator Cuff Rupture in Patients Under 55 years Old versus Patients Older than 65 Years Old.

Authors:  Thiago Medeiros Storti; Antônio Carlos Pontes Júnior; João Eduardo Simionatto; Carolina Simionatto; Rafael Salomon Silva Faria; Alexandre Firmino Paniago
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2022-02-09

Review 8.  Acupuncture Analgesia in Patients with Postoperative Neck Pain: A Protocol for Systematic Review and Meta-Analysis.

Authors:  Renming Liu; Songming Li; Yuhuan Liu; Min He; Jiazhen Cao; Mengmeng Sun; Changwei Duan; Tie Li
Journal:  Evid Based Complement Alternat Med       Date:  2022-07-20       Impact factor: 2.650

Review 9.  How to Assess Shoulder Functionality: A Systematic Review of Existing Validated Outcome Measures.

Authors:  Rocio Aldon-Villegas; Carmen Ridao-Fernández; Dolores Torres-Enamorado; Gema Chamorro-Moriana
Journal:  Diagnostics (Basel)       Date:  2021-05-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.