Literature DB >> 26222932

Variable density randomized stack of spirals (VDR-SoS) for compressive sensing MRI.

Giuseppe Valvano1,2, Nicola Martini2, Luigi Landini1,2, Maria Filomena Santarelli2,3.   

Abstract

PURPOSE: To develop a 3D sampling strategy based on a stack of variable density spirals for compressive sensing MRI.
METHODS: A random sampling pattern was obtained by rotating each spiral by a random angle and by delaying for few time steps the gradient waveforms of the different interleaves. A three-dimensional (3D) variable sampling density was obtained by designing different variable density spirals for each slice encoding. The proposed approach was tested with phantom simulations up to a five-fold undersampling factor. Fully sampled 3D dataset of a human knee, and of a human brain, were obtained from a healthy volunteer. The proposed approach was tested with off-line reconstructions of the knee dataset up to a four-fold acceleration and compared with other noncoherent trajectories.
RESULTS: The proposed approach outperformed the standard stack of spirals for various undersampling factors. The level of coherence and the reconstruction quality of the proposed approach were similar to those of other trajectories that, however, require 3D gridding for the reconstruction.
CONCLUSION: The variable density randomized stack of spirals (VDR-SoS) is an easily implementable trajectory that could represent a valid sampling strategy for 3D compressive sensing MRI. It guarantees low levels of coherence without requiring 3D gridding. Magn Reson Med 76:59-69, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  compressive Sensing MRI; random stack of spirals; variable density spirals

Mesh:

Year:  2015        PMID: 26222932     DOI: 10.1002/mrm.25847

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  3D-accelerated, stack-of-spirals acquisitions and reconstruction of arterial spin labeling MRI.

Authors:  Yulin V Chang; Marta Vidorreta; Ze Wang; John A Detre
Journal:  Magn Reson Med       Date:  2016-11-03       Impact factor: 4.668

2.  Event-recurring multiband SWIFT functional MRI with 200-ms temporal resolution during deep brain stimulation and isoflurane-induced burst suppression in rat.

Authors:  Ekaterina Paasonen; Jaakko Paasonen; Lauri J Lehto; Tiina Pirttimäki; Hanne Laakso; Lin Wu; Jun Ma; Djaudat Idiyatullin; Heikki Tanila; Silvia Mangia; Shalom Michaeli; Olli Gröhn
Journal:  Magn Reson Med       Date:  2022-01-05       Impact factor: 3.737

Review 3.  Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review.

Authors:  Amir Masoud Afsahi; Sam Sedaghat; Dina Moazamian; Ghazaleh Afsahi; Jiyo S Athertya; Hyungseok Jang; Ya-Jun Ma
Journal:  Front Endocrinol (Lausanne)       Date:  2022-05-26       Impact factor: 6.055

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.