Literature DB >> 11979575

Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation.

Hongyu An1, Weili Lin.   

Abstract

The presence of magnetic background field inhomogeneity (DeltaB) may confound quantitative measures of cerebral venous blood volume (vCBV) and cerebral oxygen extraction fraction (MR_OEF) with T2*-based methods. The goal of this study was to correct its effect and obtain more accurate estimates of vCBV and MR_OEF. A 3D high-resolution gradient echo sequence was employed to obtain DeltaB maps by two algorithms. The DeltaB maps were then used to recover the signal loss in images acquired by a 2D multiecho gradient echo / spin echo sequence. Finally, both quantitative estimates of MR_OEF and vCBV were obtained from the DeltaB- corrected 2D multiecho gradient echo / spin echo images. A total of 12 normal subjects were studied. An overestimated vCBV was observed in the brain (4.29 +/- 0.78%) prior to DeltaB correction, while the measured vCBV was substantially reduced after DeltaB correction. Whole brain vCBV of 2.97 +/- 0.44% and 2.68 +/- 0.47% were obtained by the two different DeltaB correction methods, in excellent agreement with the reported results in the literature. Furthermore, when MR_OEF was compared with and without DeltaB correction, no significant differences (P = 0.467) were observed. The ability to simultaneously obtain vCBV and MR_OEF noninvasively may have profound clinical implications for the studies of cerebrovascular disease. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11979575     DOI: 10.1002/mrm.10148

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  47 in total

1.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

Review 2.  Biophysical and physiological origins of blood oxygenation level-dependent fMRI signals.

Authors:  Seong-Gi Kim; Seiji Ogawa
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-07       Impact factor: 6.200

3.  Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique.

Authors:  Xiaoqi Wang; Alexander L Sukstanskii; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2012-05-23       Impact factor: 4.668

4.  Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Authors:  Xiang He; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

5.  NMR simulation analysis of statistical effects on quantifying cerebrovascular parameters.

Authors:  L Martyn Klassen; Ravi S Menon
Journal:  Biophys J       Date:  2006-11-03       Impact factor: 4.033

6.  R2* imaging of transfusional iron burden at 3T and comparison with 1.5T.

Authors:  Pippa Storey; Alexis A Thompson; Christine L Carqueville; John C Wood; R Andrew de Freitas; Cynthia K Rigsby
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

7.  Cerebral blood volume changes during brain activation.

Authors:  Steffen Norbert Krieger; Markus Nikolar Streicher; Robert Trampel; Robert Turner
Journal:  J Cereb Blood Flow Metab       Date:  2012-05-09       Impact factor: 6.200

8.  Oxygen metabolism in ischemic stroke using magnetic resonance imaging.

Authors:  Hongyu An; Qingwei Liu; Yasheng Chen; Katie D Vo; Andria L Ford; Jin-Moo Lee; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-13       Impact factor: 6.829

Review 9.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

10.  Validation of oxygen extraction fraction measurement by qBOLD technique.

Authors:  Xiang He; Mingming Zhu; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.