Literature DB >> 27790073

Dosimetric influence of filtered and flattening filter free photon beam on rapid arc (RA) radiotherapy planning in case of cervix carcinoma.

Lalit Kumar1, Girigesh Yadav1, Kothanda Raman Samuvel1, Manindra Bhushan1, Pawan Kumar1, Mahammood Suhail1, Manoj Pal1.   

Abstract

AIM: To investigate the dosimetric influence of filtered and flattening filter free (FFF) photon beam of 6 and 10 MV energies on cervix RA radiotherapy planning and to find possibilities to develop the clinically acceptable RA plans with FFFB photon beam and explore their potential benefits to cervix cancer patients.
BACKGROUND: FFF photon beams enhances the treatment delivery by increased dose rate which results in shorter treatment time, this shorter treatment time reduces intrafraction motion and enhance comfort to the patients.
MATERIALS AND METHODS: RA plans were generated for filtered and flattening filter free photon beams of 6 and 10 MV energies using same dose-volumes constraints. RA plans were generated to deliver a dose of 50.4 Gy in 28 fractions, for a cohort of eleven patients reported with cervix carcinoma. RA plans were evaluated in terms of PTV coverage, dose to OAR's, CI, HI, total no. of monitor units (MUs) and NTID and low dose volume of normal tissues.
RESULTS: Clinically acceptable and similar plans were generated for filtered and flattening filter free photon beams. FFFB delivered slightly higher mean target dose (52.28 Gy vs. 52.0 Gy, p = 0.000 for 6 MV and 52.42 Gy vs. 52.0 Gy, p = 0.000 for 10 MV) less homogeneous (1.062 vs. 1.052, p = 0.000 for 6 MV and 1.066 vs. 1.051, p = 0.000 for 10 MV) and less conformal (1.007 vs. 1.004, p = 0.104 for 6 MV and 1.012 vs. 1.003, p = 0.010 for 10 MV) RA plans compared to FB. FFFB delivered more doses to the bladder and rectum, also required more numbers of MUs in comparison to FB.
CONCLUSIONS: This study concludes that FB is more beneficial for cervix RA planning in comparison to FFFB, as FB generates more conformal and homogenous rapid arc plans and offers better OAR's sparing.

Entities:  

Keywords:  Cervix carcinoma; Filtered beam; Flattening filter free beam; Rapid arc plans

Year:  2016        PMID: 27790073      PMCID: PMC5071547          DOI: 10.1016/j.rpor.2016.09.010

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  17 in total

1.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm.

Authors:  Jan Hrbacek; Stephanie Lang; Stephan Klöck
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-12-02       Impact factor: 7.038

2.  A flattening filter free photon treatment concept evaluation with Monte Carlo.

Authors:  U Titt; O N Vassiliev; F Pönisch; L Dong; H Liu; R Mohan
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

3.  Treatment planning and delivery of IMRT using 6 and 18MV photon beams without flattening filter.

Authors:  Sotirios Stathakis; Carlos Esquivel; Alonso Gutierrez; Courtney R Buckey; Niko Papanikolaou
Journal:  Appl Radiat Isot       Date:  2009-03-25       Impact factor: 1.513

4.  Nontumor integral dose variation in conventional radiotherapy treatment planning.

Authors:  Warren D D'Souza; Isaac I Rosen
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

Review 5.  Current status and future perspective of flattening filter free photon beams.

Authors:  Dietmar Georg; Tommy Knöös; Brendan McClean
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

6.  Dosimetric characteristics of 6 and 10MV unflattened photon beams.

Authors:  Gabriele Kragl; Sacha af Wetterstedt; Barbara Knäusl; Mårten Lind; Patrick McCavana; Tommy Knöös; Brendan McClean; Dietmar Georg
Journal:  Radiother Oncol       Date:  2009-07-09       Impact factor: 6.280

7.  Integral dose: Comparison between four techniques for prostate radiotherapy.

Authors:  Krzysztof Ślosarek; Wojciech Osewski; Aleksandra Grządziel; Michał Radwan; Łukasz Dolla; Marta Szlag; Małgorzata Stąpór-Fudzińska
Journal:  Rep Pract Oncol Radiother       Date:  2014-11-18

8.  Second cancers following radiation treatment for cervical cancer. An international collaboration among cancer registries.

Authors:  J D Boice; N E Day; A Andersen; L A Brinton; R Brown; N W Choi; E A Clarke; M P Coleman; R E Curtis; J T Flannery
Journal:  J Natl Cancer Inst       Date:  1985-05       Impact factor: 13.506

9.  The use of photon beams of a flattening filter-free linear accelerator for hypofractionated volumetric modulated arc therapy in localized prostate cancer.

Authors:  Daniel R Zwahlen; Stephanie Lang; Jan Hrbacek; Christoph Glanzmann; Stephan Kloeck; Yousef Najafi; Tino Streller; Gabriela Studer; Kathrin Zaugg; Urs M Luetolf
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-05-07       Impact factor: 7.038

10.  Treatment-planning study of prostate cancer intensity-modulated radiotherapy with a Varian Clinac operated without a flattening filter.

Authors:  Oleg N Vassiliev; Stephen F Kry; Deborah A Kuban; Mohammad Salehpour; Radhe Mohan; Uwe Titt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-04       Impact factor: 7.038

View more
  7 in total

1.  Dosimetric impact of Acuros XB on cervix radiotherapy using RapidArc technique: a dosimetric study.

Authors:  Lalit Kumar; Vimal Kishore; Manindra Bhushan; Pawan Kumar; Rahul Lal Chaudhary
Journal:  Rep Pract Oncol Radiother       Date:  2021-08-12

2.  Effect of contrast medium on treatment modalities planned with different photon beam energies: a planning study.

Authors:  Manindra Bhushan; Deepak Tripathi; Girigesh Yadav; Lalit Kumar; Abhinav Dewan; Sarthak Tandon; Gourav Kumar; Inderjit Kaur Wahi; Munish Gairola
Journal:  Rep Pract Oncol Radiother       Date:  2021-09-30

3.  Dosimetric Influence of Acuros XB Dose-to-Medium and Dose-to-Water Reporting Modes on Carcinoma Cervix Using Intensity-Modulated Radiation Therapy and Volumetric RapidArc Technique.

Authors:  Lalit Kumar; Manindra Bhushan; Vimal Kishore; Rahul Lal Chowdhary; Soumitra Barik; Anurag Sharma; Munish Gairola
Journal:  J Med Phys       Date:  2022-02-18

4.  Dosimetric Comparison of Pencil-Beam Scanning and Photon-Based Radiation Therapy as a Boost in Carcinoma of Cervix.

Authors:  Manoj K Sharma; Eugen B Hug; Manindra Bhushan; Dennis Mah; Dominic Maes; Munish Gairola; Surender K Sharma; Girigesh Yadav; Manoj Pal; Deepika Chauhan; Abhinav Dewan; Inderjit Kaur; Sarthak Tandon; Swarupa Mitra
Journal:  Int J Part Ther       Date:  2017-12-28

5.  Impact of acuros XB algorithm in deep-inspiration breath-hold (DIBH) respiratory techniques used for the treatment of left breast cancer.

Authors:  Lalit Kumar; Vimal Kishore; Manindra Bhushan; Abhinav Dewan; Girigesh Yadav; Kothanda Raman; Gourav Kumar; Irfan Ahmad; Kundan S Chufal; Munish Gairola
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

6.  Three-dimensional dose comparison of flattening filter (FF) and flattening filter-free (FFF) radiation therapy by using NIPAM gel dosimetry.

Authors:  Chun-Hsu Yao; Tung-Hao Chang; Chia-Chi Lin; Yuan-Chun Lai; Chin-Hsing Chen; Yuan-Jen Chang
Journal:  PLoS One       Date:  2019-02-21       Impact factor: 3.240

7.  Validation of the RapidArc Delivery System Using a Volumetric Phantom as Per Task Group Report 119 of the American Association of Physicists in Medicine.

Authors:  Lalit Kumar; Girigesh Yadav; Vimal Kishore; Manindra Bhushan; Munish Gairola; Deepak Tripathi
Journal:  J Med Phys       Date:  2019 Apr-Jun
  7 in total