Interventional dual-energy imaging-Feasibility of rapid kV-switching on a C-arm CT system.

K Müller1, S Datta2, M Ahmad1, J-H Choi1, T Moore2, L Pung2, C Niebler3, G E Gold4, A Maier5, R Fahrig1.   

Abstract

PURPOSE: In the last years, dual-energy CT imaging has shown clinical value, thanks to its ability to differentiate materials based on their atomic number and to exploit different properties of images acquired at two different energies. C-arm CT systems are used to guide procedures in the interventional suite. Until now, there are no commercially available systems that employ dual-energy material decomposition. This paper explores the feasibility of implementing a fast kV-switching technique on a clinically available angiographic system for acquiring dual-energy C-arm CT images.
METHODS: As an initial proof of concept, a fast kV-switching approach was implemented on an angiographic C-arm system and the peak tube voltage during 3D rotational scans was measured. The tube voltage measurements during fast kV-switching scans were compared to corresponding measurements on kV-constant scans. Additionally, to prove stability of the requested exposure parameters, the accuracy of the delivered tube current and pulse width were also recorded and compared. In a first phantom experiment, the voxel intensity values of the individual tube voltage components of the fast kV-switching scans were compared to their corresponding kV-constant scans. The same phantom was used for a simple material decomposition between different iodine concentrations and pure water using a fast kV-switching protocol of 81 and 125 kV. In the last experiment, the same kV-switching protocol as in the phantom scan was used in an in vivo pig study to demonstrate the clinical feasibility.
RESULTS: During rapid kV-switching acquisitions, the measured tube voltage of the x-ray tube during fast switching scans has an absolute deviation of 0.23 ± 0.13 kV compared to the measured tube voltage produced during kV-constant acquisitions. The stability of the peak tube voltage over different scan requests was about 0.10 kV for the low and 0.46 for the high energy kV-switching scans and less than 0.1 kV for kV-constant scans, indicating slightly lower stability for kV-switching scans. The tube current resulted in a relative deviation of -1.6% for the low and 6.6% overestimation for the high tube voltage of the kV-switching scans compared to the kV-constant scans. The pulse width showed no deviation for the longer pulse width and only minor deviations (0.02 ± 0.02 ms) for the shorter pulse widths compared to the kV-constant scans. The phantom experiment using different iodine concentrations showed an accurate correlation (R2 > 0.99) between the extracted intensity values in the kV-switching and kV-constant reconstructed volumes, and allows for an automatic differentiation between contrast concentration down to 10% (350 mg/ml iodine) and pure water under low-noise conditions. Preliminary results of iodine and soft tissue separation showed also promising results in the first in vivo pig study.
CONCLUSIONS: The feasibility of dual-energy imaging using a fast kV-switching method on an angiographic C-arm CT system was investigated. Direct measurements of beam quality in the x-ray field demonstrate the stability of the kV-switching method. Phantom and in vivo experiments showed that images did not deviate from those of corresponding kV-constant scans. All performed experiments confirmed the capability of performing fast kV-switching scans on a clinically available C-arm CT system. More complex material decomposition tasks and postprocessing steps will be part of future investigations.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27782692      PMCID: PMC5035311          DOI: 10.1118/1.4962929

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  Frequency split metal artifact reduction (FSMAR) in computed tomography.

Authors:  Esther Meyer; Rainer Raupach; Michael Lell; Bernhard Schmidt; Marc Kachelrieß
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  C-arm computed tomography for hepatic interventions: a practical guide.

Authors:  Alessia Tognolini; John Louie; Gloria Hwang; Lawrence Hofmann; Daniel Sze; Nishita Kothary
Journal:  J Vasc Interv Radiol       Date:  2010-10-20       Impact factor: 3.464

3.  Optimization of a flat-panel based real time dual-energy system for cardiac imaging.

Authors:  Justin L Ducote; Tong Xu; Sabee Molloi
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

Review 4.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

5.  The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.

Authors:  Bernhard Krauss; Katharine L Grant; Bernhard T Schmidt; Thomas G Flohr
Journal:  Invest Radiol       Date:  2015-02       Impact factor: 6.016

6.  Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study.

Authors:  Sebastian Faby; Stefan Kuchenbecker; Stefan Sawall; David Simons; Heinz-Peter Schlemmer; Michael Lell; Marc Kachelrieß
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 7.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

8.  Dual-energy CT: vascular applications.

Authors:  Ioannis Vlahos; Raymond Chung; Arjun Nair; Robert Morgan
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

9.  Iterative image-domain decomposition for dual-energy CT.

Authors:  Tianye Niu; Xue Dong; Michael Petrongolo; Lei Zhu
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

Review 10.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

View more
  5 in total

1.  Characterization and potential applications of a dual-layer flat-panel detector.

Authors:  Linxi Shi; Minghui Lu; N Robert Bennett; Edward Shapiro; Jin Zhang; Richard Colbeth; Josh Star-Lack; Adam S Wang
Journal:  Med Phys       Date:  2020-05-18       Impact factor: 4.071

2.  Estimating the accuracy of dual energy chest radiography for coronary calcium detection with lateral or anteroposterior orientations.

Authors:  Scott S Hsieh; Matthew J Budoff
Journal:  Med Phys       Date:  2022-07-22       Impact factor: 4.506

3.  Comparative Study of Dual Energy Cone-Beam CT using a Dual-Layer Detector and kVp Switching for Material Decomposition.

Authors:  Linxi Shi; N Robert Bennett; Edward Shapiro; Richard E Colbeth; Josh Star-Lack; Minghui Lu; Adam S Wang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-16

4.  Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique.

Authors:  Shigeru Suzuki; Yoshiaki Katada; Tomoko Takayanagi; Haruto Sugawara; Takuya Ishikawa; Yuzo Yamamoto; Hiroo Wada
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

5.  3D Non-Rigid Alignment of Low-Dose Scans Allows to Correct for Saturation in Lower Extremity Cone-Beam CT.

Authors:  Jennifer Maier; Andreas Maier; Bjoern Eskofier; Rebecca Fahrig; Jang-Hwan Choi
Journal:  IEEE Access       Date:  2021-05-11       Impact factor: 3.367

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.