Literature DB >> 27750737

Comparison of two cochlear implant coding strategies on speech perception.

Margaret T Dillon1, Emily Buss1, English R King2, Ellen J Deres2, Sarah N Obarowski3, Meredith L Anderson1, Marcia C Adunka2.   

Abstract

OBJECTIVE: Assess whether differences in speech perception are observed after exclusive listening experience with high-definition continuous interleaved sampling (HDCIS) versus fine structure processing (FSP) coding strategies.
METHODS: Subjects were randomly assigned at initial activation of the external speech processor to receive the HDCIS or FSP coding strategy. Frequency filter assignments were consistent across subjects. The speech perception test battery included CNC words in quiet, HINT sentences in quiet and steady noise (+10 dB SNR), AzBio sentences in quiet and a 10-talker babble (+10 dB SNR), and BKB-SIN. Assessment intervals included 1, 3, and 6 months post-activation.
RESULTS: Data from 22 subjects (11 with HDCIS and 11 with FSP) were assessed over time. Speech perception performance was not significantly different between groups. DISCUSSION: Speech perception performance was not significantly different after 6 months of listening experience with the HDCIS or FSP coding strategy.

Entities:  

Keywords:  Cochlear implant; Processing strategy; Signal coding strategy; Speech perception

Mesh:

Year:  2016        PMID: 27750737      PMCID: PMC5895099          DOI: 10.1080/14670100.2016.1244033

Source DB:  PubMed          Journal:  Cochlear Implants Int        ISSN: 1467-0100


  27 in total

1.  Revisiting place and temporal theories of pitch.

Authors:  Andrew J Oxenham
Journal:  Acoust Sci Technol       Date:  2013

2.  Better speech recognition in noise with the fine structure processing coding strategy.

Authors:  Katrien Vermeire; Andrea Kleine Punte; Paul Van de Heyning
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  2010-09-15       Impact factor: 1.538

3.  Better speech recognition with cochlear implants.

Authors:  B S Wilson; C C Finley; D T Lawson; R D Wolford; D K Eddington; W M Rabinowitz
Journal:  Nature       Date:  1991-07-18       Impact factor: 49.962

4.  Musical Sound Quality in Cochlear Implant Users: A Comparison in Bass Frequency Perception Between Fine Structure Processing and High-Definition Continuous Interleaved Sampling Strategies.

Authors:  Alexis T Roy; Courtney Carver; Patpong Jiradejvong; Charles J Limb
Journal:  Ear Hear       Date:  2015 Sep-Oct       Impact factor: 3.570

5.  Speech understanding in quiet and in noise with the CIS speech coding strategy (MED-EL Combi-40) compared to the multipeak and spectral peak strategies (nucleus).

Authors:  J Kiefer; J Müller; T Pfennigdorff; F Schön; J Helms; C von Ilberg; W Baumgartner; W Gstöttner; K Ehrenberger; W Arnold; K Stephan; W Thumfart; S Baur
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  1996 May-Jun       Impact factor: 1.538

Review 6.  A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices.

Authors:  Paola V Incerti; Teresa Y C Ching; Robert Cowan
Journal:  Trends Amplif       Date:  2013-03

7.  Long-term improvement of speech perception with the fine structure processing coding strategy in cochlear implants.

Authors:  Andrea Kleine Punte; Marc De Bodt; Paul Van de Heyning
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  2014-03-27       Impact factor: 1.538

8.  Speech recognition with primarily temporal cues.

Authors:  R V Shannon; F G Zeng; V Kamath; J Wygonski; M Ekelid
Journal:  Science       Date:  1995-10-13       Impact factor: 47.728

9.  A "rationalized" arcsine transform.

Authors:  G A Studebaker
Journal:  J Speech Hear Res       Date:  1985-09

10.  Benefits of localization and speech perception with multiple noise sources in listeners with a short-electrode cochlear implant.

Authors:  Camille C Dunn; Ann Perreau; Bruce Gantz; Richard S Tyler
Journal:  J Am Acad Audiol       Date:  2010-01       Impact factor: 1.664

View more
  2 in total

1.  Evaluating hearing performance with cochlear implants within the same patient using daily randomization and imaging-based fitting - The ELEPHANT study.

Authors:  L J G Lambriks; M van Hoof; J A Debruyne; M Janssen; J Chalupper; K A van der Heijden; J R Hof; C A Hellingman; E L J George; E M J Devocht
Journal:  Trials       Date:  2020-06-23       Impact factor: 2.279

2.  Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners.

Authors:  Maike Klingel; Bernhard Laback
Journal:  J Assoc Res Otolaryngol       Date:  2021-11-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.