Florian Tobias Alwin Kretz1, Rahmin Khoramnia2, Mary Safwat Attia2, Michael Janusz Koss3, Katharina Linz2, Gerd Uwe Auffarth3.
Abstract
PURPOSE: To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL).Entities:
Keywords: Cataract; Low-add; Multifocal intraocular lens; Presbyopia
Mesh:
Year: 2016 PMID: 27729759 PMCID: PMC5057015 DOI: 10.3341/kjo.2016.30.5.382
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Refractive and visual results
Values are presented as mean ± standard deviation.
UDVA = uncorrected distance visual acuity; logMAR = logarithm of the minimum angle of resolution; CDVA = corrected distance visual acuity.
*Mann-Whitney test.
Fig. 1Postoperative visual acuities. UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity; UNVA = uncorrected near visual acuity; DCNVA = distance corrected near visual acuity; UIVA = uncorrected intermediate visual acuity; DCIVA = distance corrected intermediate visual acuity.
Fig. 2Cumulative binocular visual acuity for distance and intermediate. UDVA = uncorrected distance visual acuity; logMAR = logarithm of the minimum angle of resolution; UIVA = uncorrected intermediate visual acuity.
Fig. 3Monocular defocus curve (logarithm of the minimum angle of resolution, logMAR). D = diopters.
Monocular SRD results for near visual acuity
Values are presented as mean ± standard deviation.
SRD = Salzburg Reading Desk; UNVA = uncorrected near visual acuity; DCNVA = distance corrected near visual acuity; logMAR = logarithm of the minimum angle of resolution; WPM = words per minute; CPM = characters per minute.
Monocular SRD results for intermediate visual acuity
Values are presented as mean ± standard deviation.
SRD = Salzburg Reading Desk; UIVA = uncorrected intermediate visual acuity; DCIVA = distance corrected intermediate visual acuity; logMAR = logarithm of the minimum angle of resolution; WPM = words per minute; CPM = characters per minute.
Fig. 4Uncorrected visual acuity for near and intermediate distance evaluated with Salzburg Reading Desk. logMAR = logarithm of the minimum angle of resolution; sc = sine correctione (unccoreccted).
Fig. 5Distance corrected visual acuity for near and intermediate distance evaluated with Salzburg Reading Desk. logMAR = logarithm of the minimum angle of resolution; dc = distance corrected.