Literature DB >> 27723307

Hollow Polypropylene Yarns as a Biomimetic Brain Phantom for the Validation of High-Definition Fiber Tractography Imaging.

Catarina Guise1, Margarida M Fernandes1, João M Nóbrega2, Sudhir Pathak3, Walter Schneider3, Raul Fangueiro1.   

Abstract

Current brain imaging methods largely fail to provide detailed information about the location and severity of axonal injuries and do not anticipate recovery of the patients with traumatic brain injury. High-definition fiber tractography appears as a novel imaging modality based on water motion in the brain that allows for direct visualization and quantification of the degree of axons damage, thus predicting the functional deficits due to traumatic axonal injury and loss of cortical projections. This neuroimaging modality still faces major challenges because it lacks a "gold standard" for the technique validation and respective quality control. The present work aims to study the potential of hollow polypropylene yarns to mimic human white matter axons and construct a brain phantom for the calibration and validation of brain diffusion techniques based on magnetic resonance imaging, including high-definition fiber tractography imaging. Hollow multifilament polypropylene yarns were produced by melt-spinning process and characterized in terms of their physicochemical properties. Scanning electronic microscopy images of the filaments cross section has shown an inner diameter of approximately 12 μm, confirming their appropriateness to mimic the brain axons. The chemical purity of polypropylene yarns as well as the interaction between the water and the filament surface, important properties for predicting water behavior and diffusion inside the yarns, were also evaluated. Restricted and hindered water diffusion was confirmed by fluorescence microscopy. Finally, the yarns were magnetic resonance imaging scanned and analyzed using high-definition fiber tractography, revealing an excellent choice of these hollow polypropylene structures for simulation of the white matter brain axons and their suitability for constructing an accurate brain phantom.

Entities:  

Keywords:  brain phantom; high-definition fiber tractography; hollow multifilament yarns; polypropylene; water diffusion

Mesh:

Substances:

Year:  2016        PMID: 27723307     DOI: 10.1021/acsami.6b09809

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  7 in total

1.  Analysis of variability of fractional anisotropy values at 3T using a novel diffusion tensor imaging phantom.

Authors:  James M Provenzale; Brian A Taylor; Elisabeth A Wilde; Michael Boss; Walter Schneider
Journal:  Neuroradiol J       Date:  2018-07-24

2.  Fingerprinting Orientation Distribution Functions in diffusion MRI detects smaller crossing angles.

Authors:  Steven H Baete; Martijn A Cloos; Ying-Chia Lin; Dimitris G Placantonakis; Timothy Shepherd; Fernando E Boada
Journal:  Neuroimage       Date:  2019-05-16       Impact factor: 6.556

Review 3.  Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook.

Authors:  Els Fieremans; Hong-Hsi Lee
Journal:  Neuroimage       Date:  2018-06-18       Impact factor: 6.556

Review 4.  Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome.

Authors:  Susie Y Huang; Thomas Witzel; Boris Keil; Alina Scholz; Mathias Davids; Peter Dietz; Elmar Rummert; Rebecca Ramb; John E Kirsch; Anastasia Yendiki; Qiuyun Fan; Qiyuan Tian; Gabriel Ramos-Llordén; Hong-Hsi Lee; Aapo Nummenmaa; Berkin Bilgic; Kawin Setsompop; Fuyixue Wang; Alexandru V Avram; Michal Komlosh; Dan Benjamini; Kulam Najmudeen Magdoom; Sudhir Pathak; Walter Schneider; Dmitry S Novikov; Els Fieremans; Slimane Tounekti; Choukri Mekkaoui; Jean Augustinack; Daniel Berger; Alexander Shapson-Coe; Jeff Lichtman; Peter J Basser; Lawrence L Wald; Bruce R Rosen
Journal:  Neuroimage       Date:  2021-08-28       Impact factor: 7.400

5.  Validation of diffusion MRI estimates of compartment size and volume fraction in a biomimetic brain phantom using a human MRI scanner with 300 mT/m maximum gradient strength.

Authors:  Qiuyun Fan; Aapo Nummenmaa; Barbara Wichtmann; Thomas Witzel; Choukri Mekkaoui; Walter Schneider; Lawrence L Wald; Susie Y Huang
Journal:  Neuroimage       Date:  2018-01-12       Impact factor: 6.556

6.  Axon mimicking hydrophilic hollow polycaprolactone microfibres for diffusion magnetic resonance imaging.

Authors:  Feng-Lei Zhou; Zhanxiong Li; Julie E Gough; Penny L Hubbard Cristinacce; Geoff J M Parker
Journal:  Mater Des       Date:  2018-01-05       Impact factor: 7.991

7.  A comprehensive diffusion MRI dataset acquired on the MGH Connectome scanner in a biomimetic brain phantom.

Authors:  Qiuyun Fan; Aapo Nummenmaa; Barbara Wichtmann; Thomas Witzel; Choukri Mekkaoui; Walter Schneider; Lawrence L Wald; Susie Y Huang
Journal:  Data Brief       Date:  2018-03-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.