Literature DB >> 27721555

Construction of Realistic Liver Phantoms from Patient Images using 3D Printer and Its Application in CT Image Quality Assessment.

Shuai Leng1, Lifeng Yu1, Thomas Vrieze1, Joel Kuhlmann2, Baiyu Chen1, Cynthia H McCollough1.   

Abstract

The purpose of this study is to use 3D printing techniques to construct a realistic liver phantom with heterogeneous background and anatomic structures from patient CT images, and to use the phantom to assess image quality with filtered backprojection and iterative reconstruction algorithms. Patient CT images were segmented into liver tissues, contrast-enhanced vessels, and liver lesions using commercial software, based on which stereolithography (STL) files were created and sent to a commercial 3D printer. A 3D liver phantom was printed after assigning different printing materials to each object to simulate appropriate attenuation of each segmented object. As high opacity materials are not available for the printer, we printed hollow vessels and filled them with iodine solutions of adjusted concentration to represent enhance levels in contrast-enhanced liver scans. The printed phantom was then placed in a 35×26 cm oblong-shaped water phantom and scanned repeatedly at 4 dose levels. Images were reconstructed using standard filtered backprojection and an iterative reconstruction algorithm with 3 different strength settings. Heterogeneous liver background were observed from the CT images and the difference in CT numbers between lesions and background were representative for low contrast lesions in liver CT studies. CT numbers in vessels filled with iodine solutions represented the enhancement of liver arteries and veins. Images were run through a Channelized Hotelling model observer with Garbor channels and ROC analysis was performed. The AUC values showed performance improvement using the iterative reconstruction algorithm and the amount of improvement increased with strength setting.

Entities:  

Keywords:  3D Printing; Channelized Hotelling Observer; heterogeneous background; lesion detection; model observer; phantoms

Year:  2015        PMID: 27721555      PMCID: PMC5051578          DOI: 10.1117/12.2082121

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  19 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

3.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  Automatic selection of tube potential for radiation dose reduction in CT: a general strategy.

Authors:  Lifeng Yu; Hua Li; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

5.  Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver.

Authors:  Mark E Baker; Frank Dong; Andrew Primak; Nancy A Obuchowski; David Einstein; Namita Gandhi; Brian R Herts; Andrei Purysko; Erick Remer; Neil Vachhani; Neil Vachani
Journal:  AJR Am J Roentgenol       Date:  2012-07       Impact factor: 3.959

6.  Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE.

Authors:  Justin Solomon; Ehsan Samei
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

7.  Effect of reduced radiation exposure and iterative reconstruction on detection of low-contrast low-attenuation lesions in an anthropomorphic liver phantom: an 18-reader study.

Authors:  Ajit H Goenka; Brian R Herts; Nancy A Obuchowski; Andrew N Primak; Frank Dong; Wadih Karim; Mark E Baker
Journal:  Radiology       Date:  2014-03-10       Impact factor: 11.105

8.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

9.  Correlation between human and model observer performance for discrimination task in CT.

Authors:  Yi Zhang; Shuai Leng; Lifeng Yu; Rickey E Carter; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2014-05-30       Impact factor: 3.609

10.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more
  4 in total

1.  Construction of realistic phantoms from patient images and a commercial three-dimensional printer.

Authors:  Shuai Leng; Baiyu Chen; Thomas Vrieze; Joel Kuhlmann; Lifeng Yu; Amy Alexander; Jane Matsumoto; Jonathan Morris; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-07-07

2.  A Systematic Review of Three-Dimensional Printing in Liver Disease.

Authors:  Elizabeth Rose Perica; Zhonghua Sun
Journal:  J Digit Imaging       Date:  2018-10       Impact factor: 4.056

3.  Development of an organ-specific insert phantom generated using a 3D printer for investigations of cardiac computed tomography protocols.

Authors:  Kamarul A Abdullah; Mark F McEntee; Warren Reed; Peter L Kench
Journal:  J Med Radiat Sci       Date:  2018-04-30

4.  Quality control of radiomic features using 3D-printed CT phantoms.

Authors:  Usman Mahmood; Aditya Apte; Christopher Kanan; David D B Bates; Giuseppe Corrias; Lorenzo Manneli; Jung Hun Oh; Yusuf Emre Erdi; John Nguyen; Joseph O'Deasy; Amita Shukla-Dave
Journal:  J Med Imaging (Bellingham)       Date:  2021-06-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.