Literature DB >> 27714624

CORR Insights®: Operative Fluoroscopic Correction Is Reliable and Correlates With Postoperative Radiographic Correction in Periacetabular Osteotomy.

Rocco P Pitto1,2.   

Abstract

Mesh:

Year:  2016        PMID: 27714624      PMCID: PMC5339131          DOI: 10.1007/s11999-016-5111-x

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


× No keyword cloud information.
  13 in total

1.  Computer-assisted navigation in bone tumor surgery: seamless workflow model and evolution of technique.

Authors:  Timothy Y C So; Ying-Lee Lam; Ka-Lok Mak
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

2.  Computer assistance for pelvic osteotomies.

Authors:  F Langlotz; R Bächler; U Berlemann; L P Nolte; R Ganz
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

3.  Impingement adversely affects 10-year survivorship after periacetabular osteotomy for DDH.

Authors:  Christoph E Albers; Simon D Steppacher; Reinhold Ganz; Moritz Tannast; Klaus A Siebenrock
Journal:  Clin Orthop Relat Res       Date:  2013-01-25       Impact factor: 4.176

4.  Does Surgeon Experience Impact the Risk of Complications After Bernese Periacetabular Osteotomy?

Authors:  Eduardo N Novais; Patrick M Carry; Lauryn A Kestel; Brian Ketterman; Christopher M Brusalis; Wudbhav N Sankar
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

5.  Potential accuracy of navigated K-wire guided supra-acetabular osteotomies in orthopedic surgery: a CT fluoroscopy cadaver study.

Authors:  Lukas K Postl; Chlodwig Kirchhoff; Andreas Toepfer; Sonja Kirchhoff; Marcus Schmitt-Sody; Rüdiger von Eisenhart-Rothe; Rainer Burgkart
Journal:  Int J Med Robot       Date:  2016-06-08       Impact factor: 2.547

6.  CT evaluation of coverage and congruency of the hip prior to osteotomy.

Authors:  K Klaue; A Wallin; R Ganz
Journal:  Clin Orthop Relat Res       Date:  1988-07       Impact factor: 4.176

7.  Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation.

Authors:  James Min-Leong Wong; Sam Bewsher; Jielin Yew; Andrew Bucknill; Richard de Steiger
Journal:  Injury       Date:  2015-01-31       Impact factor: 2.586

8.  Image-guided periacetabular osteotomy: computer-assisted navigation compared with the conventional technique: a randomized study of 36 patients followed for 2 years.

Authors:  Pang-Hsin Hsieh; Yu-Han Chang; Chun-Hsiung Shih
Journal:  Acta Orthop       Date:  2006-08       Impact factor: 3.717

Review 9.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

10.  Clinical evaluation of a biomechanical guidance system for periacetabular osteotomy.

Authors:  Ryan J Murphy; Robert S Armiger; Jyri Lepistö; Mehran Armand
Journal:  J Orthop Surg Res       Date:  2016-03-30       Impact factor: 2.359

View more