Literature DB >> 26384172

Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement.

Philippe Pibarot1, Marie-Annick Clavel, Abdellaziz Dahou.   

Abstract

Prosthesis-patient mismatch (PPM) is frequent following surgical aortic valve replacement (SAVR) and is associated with an increased risk of morbidity and mortality. Preventive strategies to avoid or minimise PPM should be implemented in patients who are at high risk (i.e., patients with a small aortic annulus or those undergoing a valve-in-valve procedure within a small surgical bioprosthesis) and/or vulnerable to PPM (i.e., depressed left ventricular [LV] systolic function, severe LV hypertrophy, concomitant mitral regurgitation, and paradoxical low-flow, low-gradient aortic stenosis). Recent studies suggest that transcatheter aortic valve replacement (TAVR) may be superior to SAVR for the prevention of PPM and associated adverse cardiac events, particularly in the subset of patients with a small (<21 mm) aortic annulus. However, further randomised studies are needed to confirm the potential superiority of TAVR for this purpose.

Entities:  

Mesh:

Year:  2015        PMID: 26384172     DOI: 10.4244/EIJV11SWA31

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

Review 1.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

Review 2.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04
  2 in total