Literature DB >> 27677219

A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems.

Eun-Ha Kim1, Du-Hyeong Lee2, Sung-Min Kwon3, Tae-Yub Kwon4.   

Abstract

STATEMENT OF PROBLEM: Although new digital manufacturing techniques are attracting interest in dentistry, few studies have comprehensively investigated the marginal fit of fixed dental prostheses fabricated with such techniques.
PURPOSE: The purpose of this in vitro microcomputed tomography (μCT) study was to evaluate the marginal fit of cobalt-chromium (Co-Cr) alloy copings fabricated by casting and 3 different computer-aided design and computer-aided manufacturing (CAD-CAM)-based processing techniques and alloy systems.
MATERIAL AND METHODS: Single Co-Cr metal crowns were fabricated using 4 different manufacturing techniques: casting (control), milling, selective laser melting, and milling/sintering. Two different commercial alloy systems were used for each fabrication technique (a total of 8 groups; n=10 for each group). The marginal discrepancy and absolute marginal discrepancy of the crowns were determined with μCT. For each specimen, the values were determined from 4 different regions (sagittal buccal, sagittal lingual, coronal mesial, and coronal distal) by using imaging software and recorded as the average of the 4 readings. For each parameter, the results were statistically compared with 2-way analysis of variance and appropriate post hoc analysis (using Tukey or Student t test) (α=.05).
RESULTS: The milling and selective laser melting groups showed significantly larger marginal discrepancies than the control groups (70.4 ±12.0 and 65.3 ±10.1 μm, respectively; P<.001), whereas the milling/sintering groups exhibited significantly smaller values than the controls (P=.004). The milling groups showed significantly larger absolute marginal discrepancy than the control groups (137.4 ±29.0 and 139.2 ±18.9 μm, respectively; P<.05). In the selective laser melting and milling/sintering groups, the absolute marginal discrepancy values were material-specific (P<.05). Nonetheless, the milling/sintering groups yielded statistically comparable (P=.935) or smaller (P<.001) absolute marginal discrepancies to the control groups.
CONCLUSIONS: The findings of this in vitro μCT study showed that the marginal fit values of the Co-Cr alloy greatly depended on the fabrication methods and, occasionally, the alloy systems. Fixed dental prostheses produced by using the milling/sintering technique can be considered clinically acceptable in terms of marginal fit.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27677219     DOI: 10.1016/j.prosdent.2016.08.002

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

2.  Comparison of Short-Term Restorative Effects and Periodontal Health Status of Restorations Made of Different Materials in Full-Crown Restoration of Mandibular Premolar Tooth Defects.

Authors:  Liyan Zhang; Zhang Tao; Xiaoxia Wang
Journal:  Dis Markers       Date:  2022-07-01       Impact factor: 3.464

3.  Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study).

Authors:  Fatema Khaled Mansour; Rabab Mohammed Ibrahim; Hoda Mansour; Ahmed Mohamed Hamdy
Journal:  BDJ Open       Date:  2021-05-10

4.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

5.  Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods.

Authors:  Necati Kaleli; Çağrı Ural; Yeşim Ölçer Us
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

6.  Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys.

Authors:  Hang-Nga Mai; Tae-Yub Kwon; Min-Ho Hong; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2018-08-05       Impact factor: 3.411

7.  Marginal Discrepancy of Single Implant-Supported Metal Copings Fabricated by Various CAD/CAM and Conventional Techniques Using Different Materials.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Nika Soltani
Journal:  Eur J Dent       Date:  2019-11-26

8.  Casting over Metal Method Used in Manufacturing Hybrid Cobalt-Chromium Dental Prosthetic Frameworks Assembles.

Authors:  Willi Andrei Uriciuc; Horatiu Vermesan; Ancuta Elena Tiuc; Aranka Ilea; Adina Bianca Bosca; Catalin Ovidiu Popa
Journal:  Materials (Basel)       Date:  2021-01-23       Impact factor: 3.623

9.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

10.  Cobalt-chromium alloys in fixed prosthodontics in Sweden.

Authors:  Maria Kassapidou; Victoria Franke Stenport; Lars Hjalmarsson; Carina B Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-08-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.