Literature DB >> 33972501

Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study).

Fatema Khaled Mansour1, Rabab Mohammed Ibrahim2, Hoda Mansour3, Ahmed Mohamed Hamdy4.   

Abstract

STATEMENT OF PROBLEM: Accuracy of internal fit and microleakage for CAD-CAM systems used in metal coping fabrication and veneered with layering or pressing porcelain in ceramometallic restoration is unclear.
MATERIAL AND METHODS: A master metal die was milled to resemble the right mandibular first molar preparation for coverage with ceramometallic restoration. Master die was duplicated to twenty-four resin specimen dies.They were divided into two groups according to metal coping construction technique using either conventional (C) or CAD (D) wax. Each group was subdivided into two subgroups (n = 6) according to the technique of porcelain veneering (layered or pressed) to fabricate ceramometallic restorations, where subgroup (CL, DL) were conventionally layered by porcelain and (CP, DP) were press veneered. A standardized thickness of metal and porcelain was performed in all specimens as per manufacturer's instructions for techniques ceramometallic restoration construction. Evaluation of internal fit was done with silicone replica technique using stereomicroscope at ×24 magnification where the thickness of silicon layer was measured at 20 reference points on each specimen. Then specimens were subjected to thermocycling. Sectioned specimens were assessed for microleakage using a stereomicroscope at ×12 magnification along die-cement interface with a five scale score.
RESULTS: Mean internal gap values of veneering showed a statistically nonsignificant difference between specimens made with layering(L) and pressing(P). Different techniques of wax construction showed a non-significant difference in internal gap values between specimens made with conventional(C) and CAD(D) waxing. However, a significant difference was found in the internal gap at different sites. The highest internal gap was found at the occlusal surface, while the lowest gap was found at the finish line. The highest mean microleakage score was found with CAD wax and press veneering, while the lowest mean microleakage score was found with conventional wax and press veneering.
CONCLUSION: Both construction techniques of ceramometallic restoration were considered reliable in restoration production within a clinically acceptable range regarding internal fit and microleakage. There is a strong positive correlation between internal fit and microleakage of ceramometallic restoration constructed.

Entities:  

Year:  2021        PMID: 33972501     DOI: 10.1038/s41405-021-00072-7

Source DB:  PubMed          Journal:  BDJ Open        ISSN: 2056-807X


  22 in total

1.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

Review 2.  Updating Classifications of Ceramic Dental Materials: A Guide to Material Selection.

Authors:  Edward A McLaren; Johan Figueira
Journal:  Compend Contin Educ Dent       Date:  2015-06

3.  Comparison of margin discrepancy of complete gold crowns fabricated using printed, milled, and conventional hand-waxed patterns.

Authors:  Sergio Munoz; Van Ramos; Douglas P Dickinson
Journal:  J Prosthet Dent       Date:  2016-11-17       Impact factor: 3.426

4.  Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing.

Authors:  Ehsan Farjood; Mahroo Vojdani; Kiyanoosh Torabi; Amir Ali Reza Khaledi
Journal:  J Prosthet Dent       Date:  2016-07-25       Impact factor: 3.426

5.  Marginal discrepancy dimensions of single unit metal crowns fabricated by using CAD-CAM-milled acrylate resin polymer blocks or a conventional waxing technique.

Authors:  David Lalande; Jeffrey A Hodd; John S Brousseau; Van Ramos; Daniel Dunham; Frederick Rueggeberg
Journal:  J Prosthet Dent       Date:  2017-10-14       Impact factor: 3.426

6.  A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems.

Authors:  Eun-Ha Kim; Du-Hyeong Lee; Sung-Min Kwon; Tae-Yub Kwon
Journal:  J Prosthet Dent       Date:  2016-09-24       Impact factor: 3.426

7.  Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques.

Authors:  Harald Nesse; Dina Mari Åkervik Ulstein; Malene Myhre Vaage; Marit Øilo
Journal:  J Prosthet Dent       Date:  2015-07-26       Impact factor: 3.426

8.  Comparison of prosthetic models produced by traditional and additive manufacturing methods.

Authors:  Jin-Young Park; Hae-Young Kim; Ji-Hwan Kim; Jae-Hong Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

Authors:  Radhakrishnan Prabhu; Geetha Prabhu; Eswaran Baskaran; Eswaran M Arumugam
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

Review 10.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20
View more
  1 in total

1.  BDJ Open 2021 - our most successful year to date.

Authors:  Jonathan Lewney
Journal:  Br Dent J       Date:  2022-05       Impact factor: 2.727

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.