Literature DB >> 27636182

Aneurysms with persistent patency after treatment with the Pipeline Embolization Device.

Peter Kan1, Visish M Srinivasan1, Nnenna Mbabuike2, Rabih G Tawk2, Vin Shen Ban3, Babu G Welch3, Maxim Mokin4, Bartley D Mitchell1, Ajit Puri5, Mandy J Binning6,7, Edward Duckworth1.   

Abstract

The Pipeline Embolization Device (PED) was approved for the treatment of intracranial aneurysms from the petrous to the superior hypophyseal segment of the internal carotid artery. However, since its approval, its use for treatment of intracranial aneurysms in other locations and non-sidewall aneurysms has grown tremendously. The authors report on a cohort of 15 patients with 16 cerebral aneurysms that incorporated an end vessel with no significant distal collaterals, which were treated with the PED. The cohort includes 7 posterior communicating artery aneurysms, 5 ophthalmic artery aneurysms, 1 superior cerebellar artery aneurysm, 1 anterior inferior cerebellar artery aneurysm, and 2 middle cerebral artery aneurysms. None of the aneurysms achieved significant occlusion at the last follow-up evaluation (mean 24 months). Based on these observations, the authors do not recommend the use of flow diverters for the treatment of this subset of cerebral aneurysms.

Entities:  

Keywords:  AICA = anterior inferior cerebellar artery; MCA = middle cerebral artery; OphA = ophthalmic artery; PCA = posterior cerebral artery; PCoA = posterior communicating artery; PED = Pipeline Embolization Device; PICA = posterior inferior cerebellar artery; PTA = percutaneous transluminal balloon angioplasty; Pipeline Embolization Device; SCA = superior cerebellar artery; aneurysm; failure; flow diversion; interventional neurosurgery; vascular disorders

Mesh:

Year:  2016        PMID: 27636182     DOI: 10.3171/2016.6.JNS16402

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  12 in total

1.  Re-treatment of residual aneurysms after flow diversion: An experimental study.

Authors:  Robert Fahed; Tim E Darsaut; Marc Kotowski; Igor Salazkin; Jean Raymond
Journal:  Neuroradiol J       Date:  2018-03-07

2.  Aneurysm Remnants after Flow Diversion: Clinical and Angiographic Outcomes.

Authors:  T P Madaelil; J A Grossberg; B M Howard; C M Cawley; J Dion; R G Nogueira; D C Haussen; F C Tong
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-07       Impact factor: 3.825

3.  Anterior Circulation Fusiform Aneurysms Have a Lower Occlusion Rate After Pipeline Embolization Device Treatment Than Posterior Circulation Fusiform Aneurysms: A Multicenter Cohort Study.

Authors:  Chao Xu; Pei Wu; Liang Zou; Shancai Xu; Bin Luo; Xinjian Yang; Huaizhang Shi
Journal:  Front Neurol       Date:  2022-06-02       Impact factor: 4.086

4.  Incomplete occlusion and visual symptoms of peri-ophthalmic aneurysm after treatment with a pipeline embolization device: a multi-center cohort study.

Authors:  Chao Xu; Pei Wu; Bowen Sun; Shancai Xu; Bin Luo; Xinjian Yang; Huaizhang Shi
Journal:  Acta Neurochir (Wien)       Date:  2022-05-13       Impact factor: 2.816

5.  Reconsiderations on the use of pipeline embolization device in the treatment of intracerebral aneurysms with special angioarchitecture: fetal PCA, AVM, V-B junction and DAVF.

Authors:  Yupeng Zhang; Peng Yan; Yuntao Di; Fei Liang; Yuxiang Zhang; Shikai Liang; Chuhan Jiang
Journal:  Chin Neurosurg J       Date:  2018-10-01

6.  In-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials.

Authors:  Ali Sarrami-Foroushani; Toni Lassila; Michael MacRaild; Joshua Asquith; Kit C B Roes; James V Byrne; Alejandro F Frangi
Journal:  Nat Commun       Date:  2021-06-23       Impact factor: 14.919

7.  Retrospective analysis of intracranial aneurysms after flow diverter treatment including color-coded imaging (syngo iFlow) as a predictor of aneurysm occlusion.

Authors:  Andreas Simgen; Christine Mayer; Michael Kettner; Ruben Mühl-Benninghaus; Wolfgang Reith; Umut Yilmaz
Journal:  Interv Neuroradiol       Date:  2021-06-09       Impact factor: 1.764

8.  Comment on "Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery".

Authors:  Visish M Srinivasan; Peter Kan
Journal:  Case Rep Vasc Med       Date:  2017-03-15

9.  Giant vertebral aneurysm: A case report detailing successful treatment with combined stenting and surgery.

Authors:  Gabriele Capo; Maria C Vescovi; Giovanni Toniato; Benedetto Petralia; Vladimir Gavrilovic; Miran Skrap
Journal:  Surg Neurol Int       Date:  2018-01-16

Review 10.  Advances in endovascular aneurysm management: flow modulation techniques with braided mesh devices.

Authors:  Jessica K Campos; Barry Cheaney Ii; Brian V Lien; David A Zarrin; Chau D Vo; Geoffrey P Colby; Li-Mei Lin; Alexander L Coon
Journal:  Stroke Vasc Neurol       Date:  2020-03-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.