Aneurysm Remnants after Flow Diversion: Clinical and Angiographic Outcomes.

T P Madaelil1, J A Grossberg2, B M Howard1, C M Cawley1, J Dion3, R G Nogueira4, D C Haussen4, F C Tong1.   

Abstract

BACKGROUND AND
PURPOSE: Flow diversion is an established method to treat complex intracranial aneurysms. The natural history of flow-diversion treatment failure resulting in aneurysm remnants is not well-defined. We aimed to delineate the clinical and angiographic features of this entity.
MATERIALS AND METHODS: Review of a prospectively maintained Pipeline Embolization Device data base from inception to October 2017 was performed for aneurysms that demonstrated residual filling on follow-up imaging. Procedural and follow-up clinical details were recorded. Independent, blinded, angiographic assessment of occlusion was performed on the basis of the O'Kelly-Marotta scale. Aggregated outcomes were analyzed using the Fisher exact and Mann-Whitney U tests for categoric and continuous variables, respectively (statistical significance, α = .05).
RESULTS: During the study period, 283 sequential patients were treated; 87% (246/283) were women. The median patient age was 55 years (interquartile range, 47-65 years). Six-month follow-up imaging was available in 83.7% (237/283) of patients, which showed 62.4% (148/237) complete occlusion (class D, O'Kelly-Marotta grading scale). Adjunctive coiling (P = .06), on-label Pipeline Embolization Device use (P = .04), and multiple device constructs (P = .02) had higher rates of complete occlusion at 6 months. Aneurysm remnants were identified in 25 cases on long-term follow-up imaging (median, 16 months; interquartile range, 12-24 months). No patient with an aneurysm remnant after flow diversion presented with delayed rupture or other clinical sequelae, with a median clinical follow-up of 31 months (interquartile range, 23-33 months).
CONCLUSIONS: Aneurysm remnants after flow diversion are infrequent with minimal clinical impact. When appropriate, the presence of overlapping devices and possibly adjunctive coiling may result in higher rates of complete occlusion.
© 2019 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2019        PMID: 30846433      PMCID: PMC7048511          DOI: 10.3174/ajnr.A6010

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  27 in total

1.  Building multidevice pipeline constructs of favorable metal coverage: a practical guide.

Authors:  M Shapiro; E Raz; T Becske; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-27       Impact factor: 3.825

2.  Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial.

Authors:  Tibor Becske; Waleed Brinjikji; Matthew B Potts; David F Kallmes; Maksim Shapiro; Christopher J Moran; Elad I Levy; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Henry H Woo; Demetrius K Lopes; Adnan H Siddiqui; Felipe C Albuquerque; David J Fiorella; Isil Saatci; Saruhan H Cekirge; Aaron L Berez; Daniel J Cher; Zsolt Berentei; Miklós Marosfoi; Peter K Nelson
Journal:  Neurosurgery       Date:  2017-01-01       Impact factor: 4.654

3.  Neck Remnants and the Risk of Aneurysm Rupture After Endovascular Treatment With Coiling or Stent-Assisted Coiling: Much Ado About Nothing?

Authors:  Stephan A Munich; Marshall C Cress; Leonardo Rangel-Castilla; Ashish Sonig; Christopher S Ogilvy; Giuseppe Lanzino; Ondra Petr; J Mocco; Peter J Morone; Kenneth V Snyder; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy
Journal:  Neurosurgery       Date:  2019-02-01       Impact factor: 4.654

4.  Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.

Authors:  Tibor Becske; David F Kallmes; Isil Saatci; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Christopher J Moran; Henry H Woo; Demetrius K Lopes; Aaron L Berez; Daniel J Cher; Adnan H Siddiqui; Elad I Levy; Felipe C Albuquerque; David J Fiorella; Zsolt Berentei; Miklós Marosfoi; Saruhan H Cekirge; Peter K Nelson
Journal:  Radiology       Date:  2013-02-15       Impact factor: 11.105

5.  A single pipeline embolization device is sufficient for treatment of intracranial aneurysms.

Authors:  N Chalouhi; S Tjoumakaris; J L H Phillips; R M Starke; D Hasan; C Wu; M Zanaty; D Kung; L F Gonzalez; R Rosenwasser; P Jabbour
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-30       Impact factor: 3.825

6.  Complications after treatment with pipeline embolization for giant distal intracranial aneurysms with or without coil embolization.

Authors:  Adnan H Siddiqui; Peter Kan; Adib A Abla; L Nelson Hopkins; Elad I Levy
Journal:  Neurosurgery       Date:  2012-08       Impact factor: 4.654

7.  Contrast-enhanced time-resolved MRA for follow-up of intracranial aneurysms treated with the pipeline embolization device.

Authors:  S R Boddu; F C Tong; S Dehkharghani; J E Dion; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-03       Impact factor: 3.825

8.  Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization device.

Authors:  David Fiorella; Henry H Woo; Felipe C Albuquerque; Peter K Nelson
Journal:  Neurosurgery       Date:  2008-05       Impact factor: 4.654

9.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

10.  Pipeline Embolization Device with or without Adjunctive Coil Embolization: Analysis of Complications from the IntrePED Registry.

Authors:  M S Park; C Kilburg; P Taussky; F C Albuquerque; D F Kallmes; E I Levy; P Jabbour; I Szikora; E Boccardi; R A Hanel; A Bonafé; C G McDougall
Journal:  AJNR Am J Neuroradiol       Date:  2016-01-14       Impact factor: 3.825

View more
  6 in total

1.  Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter.

Authors:  T Su; P Reymond; O Brina; P Bouillot; P Machi; B M A Delattre; L Jin; K O Lövblad; M I Vargas
Journal:  AJNR Am J Neuroradiol       Date:  2020-02-13       Impact factor: 3.825

2.  Determinants of intracranial aneurysm retreatment following embolization with a single flow-diverting stent.

Authors:  Justin E Vranic; Pablo Harker; Christopher J Stapleton; Robert W Regenhardt; Adam A Dmytriw; Naif M Alotaibi; Rajiv Gupta; Thabele M Leslie-Mazwi; Matthew J Koch; Scott B Raymond; Justin R Mascitelli; T Tyler Patterson; Joshua Seinfeld; Andrew White; David Case; Christopher Roark; Chirag D Gandhi; Fawaz Al-Mufti; Jared Cooper; Aman B Patel
Journal:  Neuroradiol J       Date:  2021-11-07

3.  Neck Location on the Outer Convexity is a Predictor of Incomplete Occlusion in Treatment with the Pipeline Embolization Device: Clinical and Angiographic Outcomes.

Authors:  T Sunohara; H Imamura; M Goto; R Fukumitsu; S Matsumoto; N Fukui; Y Oomura; T Akiyama; T Fukuda; K Go; S Kajiura; M Shigeyasu; K Asakura; R Horii; C Sakai; N Sakai
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-12       Impact factor: 3.825

4.  Pipeline flow diversion with adjunctive coil embolization for internal carotid artery aneurysms following an intradural component: results in 46 consecutive aneurysms from a Japanese single-center experience.

Authors:  Tomoaki Akiyama; Hirotoshi Imamura; Masanori Goto; Ryu Fukumitsu; Tadashi Sunohara; Shirabe Matsumoto; Nobuyuki Fukui; Yoshihiro Omura; Tatsumaru Fukuda; Koichi Go; Shinji Kajiura; Masashi Shigeyasu; Kento Asakura; Ryo Horii; Yuji Naramoto; Rikuo Nishii; Yasuhiro Yamamoto; Chiaki Sakai; Nobuyuki Sakai
Journal:  Neurosurg Rev       Date:  2022-01-23       Impact factor: 3.042

5.  Usefulness of 3D T1-SPACE in Combination With 3D-TOF MRA for Follow-Up Evaluation of Intracranial Aneurysms Treated With Pipeline Embolization Devices.

Authors:  Qiuji Shao; Qiaowei Wu; Qiang Li; Tianxiao Li; Li Li; Kaitao Chang; Meiyun Wang
Journal:  Front Neurol       Date:  2020-12-11       Impact factor: 4.003

6.  Critical Angiographic and Sonographic Analysis of Intra Aneurysmal and Downstream Hemodynamic Changes After Flow Diversion.

Authors:  Radoslav Raychev; Stanimir Sirakov; Alexander Sirakov; Hamidreza Saber; Fernando Vinuela; Reza Jahan; May Nour; Viktor Szeder; Geoffrey Colby; Gary Duckwiler; Satoshi Tateshima
Journal:  Front Neurol       Date:  2022-03-10       Impact factor: 4.003

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.