Abstract

Aim Flow diverters are increasingly used to treat aneurysms, but treatment is not always effective. The management of aneurysms that fail to occlude following flow diversion is problematic. We aimed to reproduce failures in an animal model and study re-treatment with additional flow diverters alone or with flow diverters and liquid embolic agent. Material and methods Twenty wide-necked aneurysms were created at the carotid-lingual bifurcation in 10 dogs, and were treated with flow diverters 4-6 weeks later. Follow-up angiography was performed at three months. Suitable residual aneurysms were randomly allocated: re-treatment with flow diverters alone ( n = 6), or with the injection of liquid embolic between two layers of flow diverters ( n = 4) or no re-treatment ( n = 2). Angiography was repeated three months later, followed by euthanasia, photography and pathology. Results Patent wide-necked aneurysms were produced in 17/20 attempts (85%); three months after flow diversion there were 15/17 (88%) residual aneurysms. In three cases, re-treatment was not possible because the flow diverter had prolapsed into the aneurysm, leaving 12 aneurysms to study. Re-treated aneurysms showed improved angiographic results at six months (median score of 2; P = 0.03), but residual aneurysms were present in all cases. Parent artery occlusion occurred in two aneurysms treated with flow diverter plus liquid embolic. At pathology, aneurysms were only partially filled with thrombus; leaks through the flow diverters were found in the neointima connecting the arterial lumen to residual aneurysms. Conclusion Re-treatment of residual flow-diverted experimental aneurysms with additional flow diverters did not lead to aneurysm occlusion.

Entities:  

Keywords:  Experimental aneurysm; animal models; failure; flow diversion; re-treatment

Mesh:

Year:  2018        PMID: 29513077      PMCID: PMC5958507          DOI: 10.1177/1971400918763198

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  30 in total

1.  Aneurysms with persistent patency after treatment with the Pipeline Embolization Device.

Authors:  Peter Kan; Visish M Srinivasan; Nnenna Mbabuike; Rabih G Tawk; Vin Shen Ban; Babu G Welch; Maxim Mokin; Bartley D Mitchell; Ajit Puri; Mandy J Binning; Edward Duckworth
Journal:  J Neurosurg       Date:  2016-09-16       Impact factor: 5.115

2.  In vitro reproduction of device deformation leading to thrombotic complications and failure of flow diversion.

Authors:  Laurent Estrade; Alina Makoyeva; Tim E Darsaut; Jimmy Ghostine; Evgueni Kouznetsov; Igor Salazkin; Daniel Roy; Alain Weill; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

3.  Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schema.

Authors:  Mudassar Kamran; Julia Yarnold; Iris Q Grunwald; James V Byrne
Journal:  Neuroradiology       Date:  2010-09-14       Impact factor: 2.804

4.  Flow diverters can occlude aneurysms and preserve arterial branches: a new experimental model.

Authors:  T E Darsaut; F Bing; I Salazkin; G Gevry; J Raymond
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

5.  Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases.

Authors:  Timothy Hampton; Donal Walsh; Christos Tolias; David Fiorella
Journal:  J Neurointerv Surg       Date:  2011-03-01       Impact factor: 5.836

6.  Resolution of mass effect and compression symptoms following endoluminal flow diversion for the treatment of intracranial aneurysms.

Authors:  I Szikora; M Marosfoi; B Salomváry; Z Berentei; I Gubucz
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-14       Impact factor: 3.825

7.  Mechanisms of occlusion and recanalization in canine carotid bifurcation aneurysms embolized with platinum coils: an alternative concept.

Authors:  J Raymond; T Darsaut; I Salazkin; G Gevry; F Bouzeghrane
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

8.  Temporary surgical clipping of flow-diverted arteries in an experimental aneurysm model.

Authors:  Tim E Darsaut; Igor Salazkin; Jean-Christophe Gentric; Elsa Magro; Guylaine Gevry; Michel W Bojanowski; Jean Raymond
Journal:  J Neurosurg       Date:  2016-01-08       Impact factor: 5.115

9.  Onyx in an experimental aneurysm model: histological and angiographic results.

Authors:  Tobias Struffert; Christian Roth; Bernd Romeike; Iris O Grunwald; Wolfgang Reith
Journal:  J Neurosurg       Date:  2008-07       Impact factor: 5.115

10.  Compaction of flow diverters improves occlusion of experimental wide-necked aneurysms.

Authors:  Jean-Christophe Gentric; Igor Salazkin; Guylaine Gevry; Jean Raymond; Tim Darsaut
Journal:  J Neurointerv Surg       Date:  2015-10-09       Impact factor: 5.836

View more
  1 in total

Review 1.  Hydrophilic polymer embolization following flow diversion of cerebral aneurysms.

Authors:  Mohamad Abdalkader; Anvitha Sathya; Alice Ma; Anna M Cervantes-Arslanian; David Y Chung; Glenn Barest; Thanh N Nguyen
Journal:  Neuroradiol J       Date:  2021-03-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.