Literature DB >> 27610820

Prospective Comparison of Reduced-Iodine-Dose Virtual Monochromatic Imaging Dataset From Dual-Energy CT Angiography With Standard-Iodine-Dose Single-Energy CT Angiography for Abdominal Aortic Aneurysm.

Mukta D Agrawal1, George R Oliveira2, Sanjeeva P Kalva3, Daniella F Pinho3, Ronald S Arellano2, Dushyant V Sahani2.   

Abstract

OBJECTIVE: The purpose of this study was to compare the image quality of reduced-iodine-dose single-source dual-energy CT angiography (CTA) with that of standard-iodine-dose single-energy CTA in examinations of patients with abdominal aortic aneurysm and to assess the effect of the concentration of iodinated contrast medium on intravascular enhancement and image quality of reduced-iodine-dose CTA. SUBJECTS AND METHODS: In a prospective randomized clinical trial, 66 consecutively registered patients with abdominal aortic aneurysm who had previously undergone single-energy CTA (30-37 g I) underwent follow-up CTA at a reduced dose (21-27 g I) of iodinated contrast medium of either 270 mg I/mL (n = 33) or 320 mg I/mL (n = 33). Two readers independently evaluated virtual monochromatic imaging datasets (40-140 keV) and single-energy CTA images for image quality and noise and their preference for optimal energy virtual monochromatic imaging dataset. A value of p < 0.05 was considered statistically significant.
RESULTS: All 66 dual-energy CTA examinations were rated diagnostic with mean image quality and image noise scores of 4.8 and 4.5 for reader 1 and 3.8 and 3.4 for reader 2 compared with single-energy CTA results of 4.5 and 4.2 for reader 1 and 4.5 and 4.1 for reader 2. Low-energy virtual monochromatic images (40-60 keV) from reduced-iodine-dose (28%) dual-energy CTA had significantly higher intravascular aortic attenuation (26-185%) and contrast-to-noise ratio (CNR) (20-25%) than standard-iodine-dose single-energy CTA images (p < 0.0001). No significant difference was found between patients who received 270 and those who received 320 mg I/mL with respect to intravascular aortic attenuation (p = 0.6331) or CNR (p = 0.9775).
CONCLUSION: Low-energy virtual monochromatic imaging datasets from reduced-iodine (24 g I) single-source dual-energy CTA of the abdomen provide up to 185% higher attenuation and 25% higher CNR than standard-iodine-dose (33.3 g I) single-energy CTA while offering a wide range of energy settings irrespective of the concentration of IV contrast medium used.

Entities:  

Keywords:  CT angiography; abdominal aortic aneurysm; dual-energy CT; low iodine dose; virtual monochromatic imaging

Mesh:

Substances:

Year:  2016        PMID: 27610820     DOI: 10.2214/AJR.15.15814

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  13 in total

1.  Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Authors:  Ping Hou; Xiangnan Feng; Jie Liu; Yue Zhou; Yaojun Jiang; Xiaochen Jiang; Jianbo Gao
Journal:  Br J Radiol       Date:  2017-06-23       Impact factor: 3.039

2.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Clin Exp Nephrol       Date:  2020-01       Impact factor: 2.801

3.  Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Yuji Iyama; Narumi Taguchi; Tomohiro Namimoto; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Masataka Nakagawa; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-10-23       Impact factor: 5.315

4.  Accuracy of spectral curves at different phantom sizes and iodine concentrations using dual-source dual-energy computed tomography.

Authors:  Kazuhiro Sato; Ryota Kageyama; Yuta Sawatani; Hirokazu Takano; Shingo Kayano; Yumi Takane; Haruo Saito
Journal:  Phys Eng Sci Med       Date:  2021-02-02

5.  Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

Authors:  Xu Ji; Ran Zhang; Ke Li; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

6.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Jpn J Radiol       Date:  2020-01       Impact factor: 2.374

7.  Improved display of cervical intervertebral discs on water (iodine) images: incidental findings from single-source dual-energy CT angiography of head and neck arteries.

Authors:  Qingxia Wu; Dapeng Shi; Tianming Cheng; Hongming Liu; Niuniu Hu; Xiaowan Chang; Ying Guo; Meiyun Wang
Journal:  Eur Radiol       Date:  2018-06-19       Impact factor: 5.315

8.  Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction.

Authors:  Dong Han; Xiaoxia Chen; Yuxin Lei; Chunling Ma; Jieli Zhou; Yingcong Xiao; Yong Yu
Journal:  Br J Radiol       Date:  2019-07-10       Impact factor: 3.039

9.  Effects of radiation dose levels and spectral iterative reconstruction levels on the accuracy of iodine quantification and virtual monochromatic CT numbers in dual-layer spectral detector CT: an iodine phantom study.

Authors:  Xiaomei Lu; Zaiming Lu; Jiandong Yin; Yuying Gao; Xingbiao Chen; Qiyong Guo
Journal:  Quant Imaging Med Surg       Date:  2019-02

10.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.