A single reference measurement can predict liver tumor motion during respiration.

Jakub Cvek1, Lukas Knybel2, Lukas Molenda1, Bretislav Otahal1, Tomas Jonszta3, Daniel Czerny3, David Feltl1.   

Abstract

AIM: To evaluate liver tumor motion and how well reference measurement predicts motion during treatment.
MATERIAL AND METHODS: This retrospective study included 20 patients with colorectal cancer that had metastasized to the liver who were treated with stereotactic ablative radiotherapy. An online respiratory tumor tracking system was used. Tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were collected to generate patient-specific margins. Reference margins were generated as the mean motion and 95th percentile of motion from measurements recorded for different lengths of time (1, 3, and 5 min). We analyzed the predictability of tumor motion in each axis, based on the reference measurement and intra-/interfraction motions.
RESULTS: About 96,000 amplitudes were analyzed. The mean tumor motions were 9.9 ± 4.2 mm, 2.6 ± 0.8 mm, and 4.5 ± 1.8 mm in the SI, LL, and AP directions, respectively. The intrafraction variations were 3.5 ± 1.8 mm, 0.63 ± 0.35 mm, and 1.4 ± 0.65 mm for the SI, LL, and AP directions, respectively. The interfraction motion variations were 1.32 ± 0.79 mm, 0.31 ± 0.23 mm, and 0.68 ± 0.62 mm for the SI, LL, and AP directions, respectively. The Pearson's correlation coefficients for margins based on the reference measurement (mean motion or 95th percentile) and margins covering 95% of the motion during the whole treatment were 0.8-0.91, 0.57-0.7, and 0.77-0.82 in the SI, LL, and AP directions, respectively.
CONCLUSION: Liver tumor motion in the SI direction can be adequately represented by the mean tumor motion amplitude generated from a single 1 min reference measurement. Longer reference measurements did not improve results for patients who were well-educated about the importance of regular breathing. Although the study was based on tumor tracking data, the results are useful for ITV delineation when tumor tracking is not available.

Entities:  

Keywords:  Internal target volume; Liver cancer; Tumor motion

Year:  2015        PMID: 27601962      PMCID: PMC5002026          DOI: 10.1016/j.rpor.2015.11.003

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  16 in total

Review 1.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Accuracy of finite element model-based multi-organ deformable image registration.

Authors:  K K Brock; M B Sharpe; L A Dawson; S M Kim; D A Jaffray
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

Review 3.  Stereotactic body radiation therapy for oligometastases.

Authors:  Simon S Lo; Achilles J Fakiris; Bin S Teh; Higinia R Cardenes; Mark A Henderson; Jeffrey A Forquer; Lech Papiez; Ronald C McGarry; Jian Z Wang; Kaile Li; Nina A Mayr; Robert D Timmerman
Journal:  Expert Rev Anticancer Ther       Date:  2009-05       Impact factor: 4.512

4.  Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files.

Authors:  Mischa Hoogeman; Jean-Briac Prévost; Joost Nuyttens; Johan Pöll; Peter Levendag; Ben Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-01       Impact factor: 7.038

Review 5.  Stereotactic body radiotherapy: a review.

Authors:  A Martin; A Gaya
Journal:  Clin Oncol (R Coll Radiol)       Date:  2010-01-25       Impact factor: 4.126

6.  How many sets of 4DCT images are sufficient to determine internal target volume for liver radiotherapy?

Authors:  Mian Xi; Meng-Zhong Liu; Li Zhang; Qiao-Qiao Li; Xiao-Yan Huang; Hui Liu; Yong-Hong Hu
Journal:  Radiother Oncol       Date:  2009-06-10       Impact factor: 6.280

7.  Use of respiratory-correlated four-dimensional computed tomography to determine acceptable treatment margins for locally advanced pancreatic adenocarcinoma.

Authors:  Seth D Goldstein; Eric C Ford; Mario Duhon; Todd McNutt; John Wong; Joseph M Herman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-10-14       Impact factor: 7.038

8.  Locally ablative non-surgical management of colo-rectal liver metastasis.

Authors:  Amit Bahl; Rakesh Kapoor; Pramod Kumar Singh; Tapesh Bhattacharya; Oinam S Arun; Tomar Parsee; Suresh C Sharma
Journal:  J Gastrointest Cancer       Date:  2013-03

9.  Defining internal target volume (ITV) for hepatocellular carcinoma using four-dimensional CT.

Authors:  Mian Xi; Meng-Zhong Liu; Xiao-Wu Deng; Li Zhang; Xiao-Yan Huang; Hui Liu; Qiao-Qiao Li; Yong-Hong Hu; Ling Cai; Nian-Ji Cui
Journal:  Radiother Oncol       Date:  2007-08-28       Impact factor: 6.280

10.  Planning 4-dimensional computed tomography (4DCT) cannot adequately represent daily intrafractional motion of abdominal tumors.

Authors:  Jiajia Ge; Lakshmi Santanam; Camille Noel; Parag J Parikh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-10-23       Impact factor: 7.038

View more
  1 in total

1.  Intrafraction esophageal motion in patients with clinical T1N0 esophageal cancer.

Authors:  Shuhei Sekii; Yoshinori Ito; Ken Harada; Mayuka Kitaguchi; Kana Takahashi; Koji Inaba; Naoya Murakami; Hiroshi Igaki; Ryohei Sasaki; Jun Itami
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.