Literature DB >> 27576674

Force Perception Thresholds in Cochlear Implantation Surgery.

Louis B Kratchman1, Daniel Schuster, Mary S Dietrich, Robert F Labadie.   

Abstract

Tissue trauma is a frequent complication of cochlear implantation (CI) surgery, but the relationship between intracochlear trauma, electrode insertion forces, and surgeons' ability to perceive these forces is poorly understood. In this study, we simulated CI surgery using a benchtop apparatus to repeatedly apply small forces to the subjects' hands while reducing the variability in their hand movements. We used a psychophysical testing procedure to estimate the force perception thresholds of 10 otologic surgeons and found a median threshold of 20.4 mN. The results suggest that surgeons have the capability to sense at least some insertion forces and are likely to perceive severe trauma such as occurs when the electrode crosses from one scala to the other.
© 2016 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2016        PMID: 27576674      PMCID: PMC5508863          DOI: 10.1159/000445736

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  19 in total

1.  Optimizing reliability and sensitivity of Semmes-Weinstein monofilaments for establishing point tactile thresholds.

Authors:  Elisabeth H Tracey; Aaron J Greene; Richard L Doty
Journal:  Physiol Behav       Date:  2011-11-11

2.  Normal values for sensory thresholds in the cervical dermatomes: a critical note on the use of Semmes-Weinstein monofilaments.

Authors:  V F Voerman; J van Egmond; B J Crul
Journal:  Am J Phys Med Rehabil       Date:  1999 Jan-Feb       Impact factor: 2.159

3.  Semmes-weinstein monofilaments: influence of temperature, humidity, and age.

Authors:  Max H Haloua; Inger Sierevelt; Willem J Theuvenet
Journal:  J Hand Surg Am       Date:  2011-07       Impact factor: 2.230

Review 4.  Application of psychophysical techniques to haptic research.

Authors:  Lynette A Jones; Hong Z Tan
Journal:  IEEE Trans Haptics       Date:  2013 Jul-Sep       Impact factor: 2.487

Review 5.  Perception of force and weight: theory and research.

Authors:  L A Jones
Journal:  Psychol Bull       Date:  1986-07       Impact factor: 17.737

6.  Characterization of intracochlear rupture forces in fresh human cadaveric cochleae.

Authors:  Daniel Schuster; Louis B Kratchman; Robert F Labadie
Journal:  Otol Neurotol       Date:  2015-04       Impact factor: 2.311

Review 7.  Cochlear implants: current designs and future possibilities.

Authors:  Blake S Wilson; Michael F Dorman
Journal:  J Rehabil Res Dev       Date:  2008

Review 8.  Identifying patients with diabetes mellitus who are at risk for lower-extremity complications: use of Semmes-Weinstein monofilaments.

Authors:  M J Mueller
Journal:  Phys Ther       Date:  1996-01

9.  Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool.

Authors:  Omid Majdani; Daniel Schurzig; Andreas Hussong; Thomas Rau; Justin Wittkopf; Thomas Lenarz; Robert F Labadie
Journal:  Acta Otolaryngol       Date:  2010       Impact factor: 1.494

10.  In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea.

Authors:  Margaret W Skinner; Timothy A Holden; Bruce R Whiting; Arne H Voie; Barry Brunsden; J Gail Neely; Eugene A Saxon; Timothy E Hullar; Charles C Finley
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  2007-04
View more
  6 in total

1.  Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes.

Authors:  Silke Hügl; Katharina Rülander; Thomas Lenarz; Omid Majdani; Thomas S Rau
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-10-09       Impact factor: 2.503

2.  Human Otopathologic Findings in Cases of Folded Cochlear Implant Electrodes.

Authors:  Danielle R Trakimas; Elliott D Kozin; Iman Ghanad; Joseph B Nadol; Aaron K Remenschneider
Journal:  Otol Neurotol       Date:  2018-09       Impact factor: 2.311

3.  Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

Authors:  Marjan Mirsalehi; Thomas S Rau; Lenka Harbach; Silke Hügl; Saleh Mohebbi; Thomas Lenarz; Omid Majdani
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-02-25       Impact factor: 2.503

4.  Insertion Guidance Based on Impedance Measurements of a Cochlear Electrode Array.

Authors:  Enver Salkim; Majid Zamani; Dai Jiang; Shakeel R Saeed; Andreas Demosthenous
Journal:  Front Comput Neurosci       Date:  2022-06-23       Impact factor: 3.387

5.  Impedance Measures During in vitro Cochlear Implantation Predict Array Positioning.

Authors:  Christopher Kenneth Giardina; Elliot Samuel Krause; Kanthaiah Koka; Douglas Carl Fitzpatrick
Journal:  IEEE Trans Biomed Eng       Date:  2018-02       Impact factor: 4.538

6.  Drug delivery device for the inner ear: ultra-sharp fully metallic microneedles.

Authors:  Aykut Aksit; Shruti Rastogi; Maria L Nadal; Amber M Parker; Anil K Lalwani; Alan C West; Jeffrey W Kysar
Journal:  Drug Deliv Transl Res       Date:  2021-02       Impact factor: 4.617

  6 in total