Literature DB >> 27570691

Comparison of tissue oximeters on a liquid phantom with adjustable optical properties.

S Kleiser1, N Nasseri2, B Andresen3, G Greisen3, M Wolf4.   

Abstract

The SafeBoosC trial showed that cerebral oximetry combined with a treatment guideline can reduce the the burden of hypoxia in neonates by 50% [Brit. Med. J.350, g7635 (2015)]. However, guidelines based on oximetry by one oximeter are not directly usable by other oximeters. We made a blood-lipid phantom simulating the neonatal head to determine the relation between oxygenation values obtained by different oximeters. We calculated coefficients for easy conversion from one oximeter to the other. We additionally determined the corresponding SafeBoosC intervention thresholds at which we measured an uncertainty of up to 9.2% when varying hemoglobin content from 25μM to 70μM. In conclusion, this paper makes the comparison of absolute values obtained by different oximeters possible.

Entities:  

Keywords:  (120.3890) Medical optics instrumentation; (170.6510) Spectroscopy, tissue diagnostics

Year:  2016        PMID: 27570691      PMCID: PMC4986807          DOI: 10.1364/BOE.7.002973

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  40 in total

1.  ABSORPTION SPECTRUM OF ACTIVELY RESPIRING YEAST CELLS.

Authors:  Y NOSOH
Journal:  Arch Biochem Biophys       Date:  1964-05       Impact factor: 4.013

Review 2.  Anaerobic storage of red blood cells.

Authors:  Tatsuro Yoshida; Sergey S Shevkoplyas
Journal:  Blood Transfus       Date:  2010-10       Impact factor: 3.443

3.  Comparison of Near-Infrared Oximeters in a Liquid Optical Phantom with Varying Intralipid and Blood Content.

Authors:  S Kleiser; S Hyttel-Sorensen; G Greisen; M Wolf
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

4.  Comparison of cerebral tissue oxygenation values in full term and preterm newborns by the simultaneous use of two near-infrared spectroscopy devices: an absolute and a relative trending oximeter.

Authors:  Tomasz Szczapa; Łukasz Karpiński; Jerzy Moczko; Michael Weindling; Alicja Kornacka; Katarzyna Wróblewska; Aleksandra Adamczak; Aleksandra Jopek; Karolina Chojnacka; Janusz Gadzinowski
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

5.  Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy.

Authors:  J G Kim; H Liu
Journal:  Phys Med Biol       Date:  2007-10-02       Impact factor: 3.609

6.  Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation.

Authors:  C D Kurth; B Uher
Journal:  Anesth Analg       Date:  1997-06       Impact factor: 5.108

7.  Local Measurement of Flap Oxygen Saturation: An Application of Visible Light Spectroscopy.

Authors:  Nassim Nasseri; Stefan Kleiser; Sascha Reidt; Martin Wolf
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

8.  Tissue-like phantoms for near-infrared fluorescence imaging system assessment and the training of surgeons.

Authors:  Alec M De Grand; Stephen J Lomnes; Deborah S Lee; Matthew Pietrzykowski; Shunsuke Ohnishi; Timothy G Morgan; Andrew Gogbashian; Rita G Laurence; John V Frangioni
Journal:  J Biomed Opt       Date:  2006 Jan-Feb       Impact factor: 3.170

9.  Measurement of the oxidation state of mitochondrial cytochrome c from the neocortex of the mammalian brain.

Authors:  Y Sakata; M Abajian; M O Ripple; R Springett
Journal:  Biomed Opt Express       Date:  2012-07-25       Impact factor: 3.732

10.  Cerebral near infrared spectroscopy oximetry in extremely preterm infants: phase II randomised clinical trial.

Authors:  Simon Hyttel-Sorensen; Adelina Pellicer; Thomas Alderliesten; Topun Austin; Frank van Bel; Manon Benders; Olivier Claris; Eugene Dempsey; Axel R Franz; Monica Fumagalli; Christian Gluud; Berit Grevstad; Cornelia Hagmann; Petra Lemmers; Wim van Oeveren; Gerhard Pichler; Anne Mette Plomgaard; Joan Riera; Laura Sanchez; Per Winkel; Martin Wolf; Gorm Greisen
Journal:  BMJ       Date:  2015-01-05
View more
  35 in total

1.  Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy.

Authors:  Nassim Nasseri; Stefan Kleiser; Daniel Ostojic; Tanja Karen; Martin Wolf
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

2.  Chromophore decomposition in multispectral time-resolved diffuse optical tomography.

Authors:  Judy Zouaoui; Laura Di Sieno; Lionel Hervé; Antonio Pifferi; Andrea Farina; Alberto Dalla Mora; Jacques Derouard; Jean-Marc Dinten
Journal:  Biomed Opt Express       Date:  2017-09-28       Impact factor: 3.732

3.  Comparison of tissue oximeters on a liquid phantom with adjustable optical properties: an extension.

Authors:  S Kleiser; D Ostojic; B Andresen; N Nasseri; H Isler; F Scholkmann; T Karen; G Greisen; M Wolf
Journal:  Biomed Opt Express       Date:  2017-12-05       Impact factor: 3.732

4.  Dual-slope method for enhanced depth sensitivity in diffuse optical spectroscopy.

Authors:  Angelo Sassaroli; Giles Blaney; Sergio Fantini
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2019-10-01       Impact factor: 2.129

5.  Small separation frequency-domain near-infrared spectroscopy for the recovery of tissue optical properties at millimeter depths.

Authors:  Seung Yup Lee; Corey Zheng; Rowan Brothers; Erin M Buckley
Journal:  Biomed Opt Express       Date:  2019-09-27       Impact factor: 3.732

6.  Monte-Carlo simulation and tissue-phantom model for validation of ocular oximetry.

Authors:  Cléophace Akitegetse; Patricia Landry; Jonathan Robidoux; Nicolas Lapointe; Danny Brouard; Dominic Sauvageau
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

7.  Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom.

Authors:  Ali Afshari; Rolf B Saager; David Burgos; William C Vogt; Jianting Wang; Gonzalo Mendoza; Sandy Weininger; Kung-Bin Sung; Anthony J Durkin; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

8.  MAESTROS: A Multiwavelength Time-Domain NIRS System to Monitor Changes in Oxygenation and Oxidation State of Cytochrome-C-Oxidase.

Authors:  Frederic Lange; Luke Dunne; Lucy Hale; Ilias Tachtsidis
Journal:  IEEE J Sel Top Quantum Electron       Date:  2018-05-09       Impact factor: 4.544

9.  A hyperspectral imaging system for mapping haemoglobin and cytochrome-c-oxidase concentration changes in the exposed cerebral cortex.

Authors:  Luca Giannoni; Frédéric Lange; Marija Sajic; Kenneth J Smith; Ilias Tachtsidis
Journal:  IEEE J Sel Top Quantum Electron       Date:  2021-01-22       Impact factor: 4.544

10.  Cerebral oxygen saturation and autoregulation during hypotension in extremely preterm infants.

Authors:  Liesbeth Thewissen; Gunnar Naulaers; Dries Hendrikx; Alexander Caicedo; Keith Barrington; Geraldine Boylan; Po-Yin Cheung; David Corcoran; Afif El-Khuffash; Aisling Garvey; Jozef Macko; Neil Marlow; Jan Miletin; Colm P F O'Donnell; John M O'Toole; Zbyněk Straňák; David Van Laere; Hana Wiedermannova; Eugene Dempsey
Journal:  Pediatr Res       Date:  2021-04-20       Impact factor: 3.756

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.