Literature DB >> 9174310

Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation.

C D Kurth1, B Uher.   

Abstract

Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcranial optical pathlength and cerebral hemoglobin concentration as sources for this intersubject variability. Experiments were performed in an in vitro brain model and in piglets. Optical pathlength and cerebral hemoglobin concentration were measured by time-resolved spectroscopy (TRS). NIRS and TRS were recorded in the model, as perfusate blood saturation was varied (0%-100%) at several hemoglobin concentrations, and in piglets, as SMO2 was varied (15%-90%) before and after hemodilution. In the model, hemoglobin concentration significantly altered the NIRS versus blood saturation line slope and intercept, as well as optical pathlength. In piglets (before hemodilution), there was significant intersubject variability in NIRS versus SMO2 line slope (0.73-1.4) and intercept (-24 to 36) and in transcranial optical pathlength (13.4-16 cm) and cerebral hemoglobin concentration (0.58-1.1 g/dL). By adjusting the NIRS algorithm with optical pathlength or cerebral hemoglobin measurements, intersubject variability in slope (0.9-1.2) and intercept (-9 to 18) decreased significantly. Hemodilution significantly changed NIRS versus SMO2 line slope and intercept, as well as transcranial optical pathlength and cerebral hemoglobin concentration (before versus after hemodilution: slope 0.9 vs 0.78, intercept 13 vs 19, pathlength 13.9 vs 15.6 cm, cerebral hemoglobin 0.98 vs 0.73 g/dL). By adjusting the NIRS algorithm with the cerebral hemoglobin measurements, slope and intercept remained unchanged by hemodilution. These data indicate that intersubject variability in NIRS originates, in part, from biologic variations in transcranial optical pathlength and cerebral hemoglobin concentration. Instruments to account for these factors may improve NIRS cerebral oxygen saturation measurements.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9174310     DOI: 10.1097/00000539-199706000-00023

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

Review 1.  The clinical validity of the absolute value of near infrared spectroscopy.

Authors:  Kenji Yoshitani; Yoshihiko Ohnishi
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

2.  Comparison of tissue oximeters on a liquid phantom with adjustable optical properties.

Authors:  S Kleiser; N Nasseri; B Andresen; G Greisen; M Wolf
Journal:  Biomed Opt Express       Date:  2016-07-11       Impact factor: 3.732

3.  Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exercise.

Authors:  Laura Ellwein; Margaret M Samyn; Michael Danduran; Sheila Schindler-Ivens; Stacy Liebham; John F LaDisa
Journal:  Biomech Model Mechanobiol       Date:  2016-07-04

4.  Uncontrolled hypertension and orthostatic hypotension in relation to standing balance in elderly hypertensive patients.

Authors:  Shanshan Shen; Ting He; Jiaojiao Chu; Jin He; Xujiao Chen
Journal:  Clin Interv Aging       Date:  2015-05-28       Impact factor: 4.458

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.