Literature DB >> 29359089

Comparison of tissue oximeters on a liquid phantom with adjustable optical properties: an extension.

S Kleiser1, D Ostojic1, B Andresen2, N Nasseri1,3, H Isler1, F Scholkmann1,3, T Karen4, G Greisen2, M Wolf1.   

Abstract

Cerebral near-infrared spectroscopy (NIRS) oximetry may help clinicians to improve patient treatment. However, the application of NIRS oximeters is increasingly causing confusion to the users due to the inconsistency of tissue oxygen haemoglobin saturation (StO2) readings provided by different oximeters. To establish a comparability of oximeters, in our study we performed simultaneous measurements on the liquid phantom mimicking properties of neonatal heads and compared the tested device to a reference NIRS oximeter (OxiplexTS). We evaluated the NIRS oximeters FORE-SIGHT, NIRO and SenSmart, and reproduced previous results with the INVOS and OxyPrem v1.3 oximeters. In general, linear relationships of the StO2 values with respect to the reference were obtained. Device specific hypoxic and hyperoxic thresholds (as used in the SafeBoosC study, www.safeboosc.eu) and a table allowing for conversion of StO2 values are provided.

Entities:  

Keywords:  (120.3890) Medical optics instrumentation; (170.6510) Spectroscopy, tissue diagnostics

Year:  2017        PMID: 29359089      PMCID: PMC5772591          DOI: 10.1364/BOE.9.000086

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  44 in total

1.  Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.

Authors:  Philip E Bickler; John R Feiner; Mark D Rollins
Journal:  Anesth Analg       Date:  2013-09-10       Impact factor: 5.108

2.  Influence of a superficial layer in the quantitative spectroscopic study of strongly scattering media.

Authors:  M A Franceschini; S Fantini; L A Paunescu; J S Maier; E Gratton
Journal:  Appl Opt       Date:  1998-11-01       Impact factor: 1.980

3.  Quantitative spectroscopic determination of hemoglobin concentration and saturation in a turbid medium: analysis of the effect of water absorption.

Authors:  M A Franceschini; S Fantini; A E Cerussi; B B Barbieri; B Chance; E Gratton
Journal:  J Biomed Opt       Date:  1997-04       Impact factor: 3.170

4.  Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy.

Authors:  J G Kim; H Liu
Journal:  Phys Med Biol       Date:  2007-10-02       Impact factor: 3.609

Review 5.  Validity and reliability of the SjO2 catheter in neurologically impaired patients: a critical review of the literature.

Authors:  H D Clay
Journal:  J Neurosci Nurs       Date:  2000-08       Impact factor: 1.230

6.  Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy.

Authors:  Nassim Nasseri; Stefan Kleiser; Daniel Ostojic; Tanja Karen; Martin Wolf
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

7.  Comparison of tissue oximeters on a liquid phantom with adjustable optical properties.

Authors:  S Kleiser; N Nasseri; B Andresen; G Greisen; M Wolf
Journal:  Biomed Opt Express       Date:  2016-07-11       Impact factor: 3.732

Review 8.  Effects of Acute, Profound Hypoxia on Healthy Humans: Implications for Safety of Tests Evaluating Pulse Oximetry or Tissue Oximetry Performance.

Authors:  Philip E Bickler; John R Feiner; Michael S Lipnick; Paul Batchelder; David B MacLeod; John W Severinghaus
Journal:  Anesth Analg       Date:  2017-01       Impact factor: 5.108

9.  Cerebral near infrared spectroscopy oximetry in extremely preterm infants: phase II randomised clinical trial.

Authors:  Simon Hyttel-Sorensen; Adelina Pellicer; Thomas Alderliesten; Topun Austin; Frank van Bel; Manon Benders; Olivier Claris; Eugene Dempsey; Axel R Franz; Monica Fumagalli; Christian Gluud; Berit Grevstad; Cornelia Hagmann; Petra Lemmers; Wim van Oeveren; Gerhard Pichler; Anne Mette Plomgaard; Joan Riera; Laura Sanchez; Per Winkel; Martin Wolf; Gorm Greisen
Journal:  BMJ       Date:  2015-01-05

10.  A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements.

Authors:  Paul B Benni; David MacLeod; Keita Ikeda; Hung-Mo Lin
Journal:  J Clin Monit Comput       Date:  2017-04-03       Impact factor: 2.502

View more
  26 in total

Review 1.  In vivo validation of cerebral near-infrared spectroscopy: a review.

Authors:  Amalie la Cour; Gorm Greisen; Simon Hyttel-Sorensen
Journal:  Neurophotonics       Date:  2018-11-27       Impact factor: 3.593

2.  Characterization of connective tissues using near-infrared spectroscopy and imaging.

Authors:  Isaac O Afara; Rubina Shaikh; Ervin Nippolainen; William Querido; Jari Torniainen; Jaakko K Sarin; Shital Kandel; Nancy Pleshko; Juha Töyräs
Journal:  Nat Protoc       Date:  2021-01-18       Impact factor: 13.491

3.  Evaluation of hyperspectral NIRS for quantitative measurements of tissue oxygen saturation by comparison to time-resolved NIRS.

Authors:  Matthew Kewin; Ajay Rajaram; Daniel Milej; Androu Abdalmalak; Laura Morrison; Mamadou Diop; Keith St Lawrence
Journal:  Biomed Opt Express       Date:  2019-08-23       Impact factor: 3.732

4.  Monte-Carlo simulation and tissue-phantom model for validation of ocular oximetry.

Authors:  Cléophace Akitegetse; Patricia Landry; Jonathan Robidoux; Nicolas Lapointe; Danny Brouard; Dominic Sauvageau
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

5.  Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom.

Authors:  Ali Afshari; Rolf B Saager; David Burgos; William C Vogt; Jianting Wang; Gonzalo Mendoza; Sandy Weininger; Kung-Bin Sung; Anthony J Durkin; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

6.  A phase-II clinical trial of targeted cerebral near infrared spectroscopy using standardized treatment guidelines to improve brain oxygenation in preterm infants (BOx-II): A study protocol.

Authors:  Zachary Vesoulis; Andrew Hopper; Karen Fairchild; Santina Zanelli; Lina Chalak; Mona Noroozi; Jessica Liu; Valerie Chock
Journal:  Contemp Clin Trials       Date:  2022-08-19       Impact factor: 2.261

7.  Quantifying the Cerebral Hemometabolic Response to Blood Transfusion in Pediatric Sickle Cell Disease With Diffuse Optical Spectroscopies.

Authors:  Seung Yup Lee; Rowan O Brothers; Katherine B Turrentine; Ayesha Quadri; Eashani Sathialingam; Kyle R Cowdrick; Scott Gillespie; Shasha Bai; Adam E Goldman-Yassen; Clinton H Joiner; R Clark Brown; Erin M Buckley
Journal:  Front Neurol       Date:  2022-07-01       Impact factor: 4.086

8.  Osteopathic Manipulation Treatment Improves Cerebro-splanchnic Oximetry in Late Preterm Infants.

Authors:  Benedetta Marinelli; Francesca Pluchinotta; Vincenzo Cozzolino; Gina Barlafante; Maria Chiara Strozzi; Eleonora Marinelli; Simone Franchini; Diego Gazzolo
Journal:  Molecules       Date:  2019-09-04       Impact factor: 4.411

9.  Valence and Intensity of Video Stimuli of Dogs and Conspecifics in Sheep: Approach-Avoidance, Operant Response, and Attention.

Authors:  Camille M C Raoult; Lorenz Gygax
Journal:  Animals (Basel)       Date:  2018-07-17       Impact factor: 2.752

10.  Comparison of frequency-domain and continuous-wave near-infrared spectroscopy devices during the immediate transition.

Authors:  Tanja van Essen; Tom G Goos; Liza van Ballegooijen; Gerhard Pichler; Berndt Urlesberger; Irwin K M Reiss; Rogier C J de Jonge
Journal:  BMC Pediatr       Date:  2020-02-28       Impact factor: 2.125

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.