Literature DB >> 27555899

Three dimensional deformation of dry-stored complete denture base at room temperature.

Seo-Ryeon Lim1, Joon-Seok Lee1.   

Abstract

PURPOSE: The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program.
MATERIALS AND METHODS: A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at 1(st) day after deflasking, 14(th) day after deflasking, and 28(th) day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (α=.05).
RESULTS: When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found.
CONCLUSION: It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern.

Entities:  

Keywords:  3D surface matching software; Denture base; Denture storage method; Dimensional deformation; Dry storage

Year:  2016        PMID: 27555899      PMCID: PMC4993843          DOI: 10.4047/jap.2016.8.4.296

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


INTRODUCTION

Polymethyl methacrylate (PMMA) as denture base material has many advantages including adequate mechanical strength, esthetics, low toxicity, easiness of repair, and can be cured by simple procedures, therefore, PMMA has been the most commonly used for fabricating denture base since it was developed in the mid-1945.12 However, PMMA resin also has some disadvantages as denture base, and one of these is dimensional change after processing was completed. Dimensional change of denture base resin can be occurred by curing shrinkage and expansion through water absorption,3 and other former studies stated that dimensional change would be a result of polymerization shrinkage,45 thermal shrinkage,46 internal stress release,6 water absorption,78 and dry shrinkage.9 The denture base after curing may have shrunk linearly as much as approximately 0.5%.10 It could lead distortion of the denture, and although this shrinkage may be compensated with expansion by water absorption, this change would result in poor adaptation of the denture to its tissue, and decrease of denture stability and retention.611 Concerning water absorption, some studies demonstrated that the greatest dimensional changes was occurred during the first month and no remarkable changes took place after two months.12 Due to PMMA denture base should be influenced by water absorption, some authors insisted that occlusal adjustment of denture would be delayed until PMMA has become saturated with water.7 However, Some authors researched about changes in dentures during storage in water and in service for 18 months, and concluded a posterior linear expansion of heat curing resin was less than 1.0% and the dimensional changes did not affected the fit of denture,8 and other studies also reported that there was no significant volumetric deformation in denture when denture was being stored in water.13 Most of previous studies tried to measure deformation and accuracy of the denture 2-dimensionally.141516 Nowadays, some authors tried to investigate the dimensional stability, and it is possible to compare two objects three-dimensionally by using surface matching program and scanning device.17 It is well known that denture should be stored in the water in order to minimize distortion and shrinkage, when they are once removed from the mouth.714 However, it was not known shrinkage was occurred in certain pattern of form when denture was kept in dry condition, nor which portion of the denture should be watched carefully, if the patient who stores his denture in the air comes and want to relieve discomfort due to his denture. The purpose of this study was to evaluate whether there is any typical deformation pattern of complete denture that was stored in the air, and if any, to find out what typical pattern would be by using the 3D scanner and surface matching program.

MATERIALS AND METHODS

For fabricating upper and lower denture base, maxillary and mandibular edentulous models with little undercut were selected. Additional silicone material (Honigum, DMG, Hamburg, Germany) was used for duplicating edentulous model. The silicone molds were poured with improved stone (Fujirock EP pastel yellow; GC America Inc., Alsip, IL, USA) thus total 28 master casts, including 14 maxillary and 14 mandibular models, were fabricated. After trimming the master cast, recording base with 2.0 mm thickness was made with auto-polymerizing resin (Quicky, Nissin dental product, Inc., Kyoto, Japan) on each cast. After adjusting and confirming uniform thickness, each recording base was sit onto the corresponding cast and gap between recording base and master cast was sealed with molten baseplate wax. Processing and curing procedure was performed by conventional compression method. After waxes were washed out with boiling water, heat polymerized acrylic resin (Lucitone 199, Dentsply International Inc, York, NY, USA) was packed into the mold and polymerized for 9 hours at 72℃ and maintained for 30 minutes at 100℃. Flasks were cooled down to room temperature in the water for 12 hours. After denture base was removed from the cast, any nodule or fin edge on the denture base are carefully removed with acrylic bur. Total 28 denture bases were fabricated, and 14 denture bases (7 upper and 7 lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Acrylic resin denture bases were scanned to construct digital 3D model. 3D laser scanner (MyScan Specification, RaphaBio, Seoul, Korea), which could detect 0.02 mm difference was used for digitizing the denture base. To confirm that denture specimen was mounted on the similar position of the scan table, silicone putty index was fabricated for each denture base specimen and each denture base was mounted with it. Scanned data was saved as stereolithography (STL) file using data compatible program (MyDesign, Raphabio, Seoul, Korea). Internal surface of each specimen was scanned at 1st day, 14th day and 28th day after deflasking. 3D scan data of internal surface of denture base were categorized depending on the storage method (W; water storage, D; dried storage), and subdivided into T1, T2, and T3 according to duration from deflasking to scanned time; 1st day after deflasking, 14th day after deflasking, and 28th day after deflasking, respectively. Three dimensional deformation patterns were acquired by overlapping the scanned data between T1 and T2, T2 and T3, and T1 and T3 of each storage group by 3D surface matching program (Geomagic Qualify; Raindrop Geomagic, Research Triangle Park, NC, USA). Before performing best-fit alignment, unnecessary portion of the imported image except internal surface was eliminated. Best-fit alignment is the arranging process via matching repeatedly the closest points of corresponding images in the virtual space on the program, and permits to measure morphologic differences in form.17 In this study, 300,000 to 600,000 random points were used for this alignment. After best-fit alignment procedure, the images of T1 and T2, T2 and T3, and T1 and T3 within each storage group (W and D) were compared, and the results of surface matching in storage group W and D were named as group Wa, group Wb and group Wc, and group Da, group Db and group Dc, respectively, in each upper and lower denture bases. As a result, 7 color-coded maps were created in each image group (Table 1). When 3D compare was conducted, the maximum and minimum nominal values were set at ± 0.05 mm and the maximum and minimum critical values were set at ± 1.0 mm. On color-coded map, positive deformation that represent internal surface of the test model (the latter) was located above that of the reference model (the former) was expressed in the red to yellow color segments and negative deformation that represent internal surface of the test model was located lower than that of the reference model was expressed in color from cyan to deep blue.
Table 1

Classification of maxillary (M) and mandibular (N) groups in this study

Storage methodGroupsOverlapping betweenNo. of specimen
MaxillaMandible
Water storage (W)MWaNwaT1 and T27
MWbNWbT2 and T37
MWcNWcT1 and T37
Dried storage (D)MDaNDaT1 and T27
MDbNDbT2 and T37
MDcNDcT1 and T37
For evaluating the deformation pattern in detail, cross-sectional 2-D comparison was also performed. Cross sectional view was created in med-palatal area (sagittally) and posterior molar area (frontally). Statistical analyses were performed by IBM SPSS (SPSS v.22, IBM Corp., Armonk, NY, USA). The median, inter-quartile range, the maximum and minimum values of the positive and the negative deformation were measured. For evaluating differences between groups, these data were statistically compared at 95% significance level using Kruskal-Wallis test and Mann-Whitney U test for post hoc analysis.

RESULTS

Generally, when evaluating 3D deformation of denture base in upper denture bases major deformation pattern could not be seen in group W according to the elapse of time. However, in group D, deformation pattern was detected as storage time passes. Also, in lower denture bases, major and repeating deformation could be seen in group D. Figure 1, 2 represent the typical case of the color-coded map of groups and shows deformation pattern of both storage groups of upper denture bases, and Figure 3, 4 represent deformation pattern of both storage groups of lower denture bases. In the water storage group, although little deformation was observed at some area of all groups, area of deformation was very small and any repeated or specific pattern was not found (Fig. 1, Fig. 3).
Fig. 1

Typical feature of color coded maps of water-stored upper denture base. (A) MWa, (B) MWb, (C) MWc.

Fig. 2

Typical feature of color coded maps of dry-stored upper denture base. (A) MDa, (B) MDb, (C) MDc.

Fig. 3

Typical feature of color coded maps of water-stored lower denture base. (A) NWa, (B) NWb, (C) NWc.

Fig. 4

Typical feature of color coded maps of dry-stored lower denture bases. (A) NDa, (B) NDb, (C) NDc.

In the dry-stored group of upper denture bases, when compared between first 2 weeks, deformation was found in the bilateral posterior buccal flange area (yellow) which means decrease in distance between posterior flanges, and also found in posterior palatal seal area (cyan) which means negative deformation was occurred in that area. However, when compared between second 2 weeks, significant deformation pattern was reduced. Therefore, results of color-coded map of subgroup MDa and MDc showed similar pattern (Fig. 2). These findings were repeatedly confirmed with results of 2 D compare procedure. In the dry-stored group of lower denture bases, more obvious deformation was observed at posterior buccal flange area (cyan) and buccal shelf and retromolar pad (yellow) than in water-stored group. Result of Kruskal-Wallis test demonstrated that there are no significant differences in overall, positive, and negative deformation among subgroups in both maxillary and mandibular water storage group (Table 2 and Table 3). In the maxillary dried storage group, there were significant different between subgroups and Mann whitney U test was performed. (Table 4) When overall deformation between subgroups was compared, significant differences were found between MDa (median: 0.040 mm) and MDb (median: 0.000 mm), and also between MDb and MDc (median: 0.040 mm). When positive deformation was only concerned, statistical results were similar with that of overall deformation (median of MDa: 0.032 mm, median of MDb: 0.017 mm, median of MDc: 0.039 mm). However, when negative deformation was compared, there are no significant differences among subgroups. In the Mandibular dried storage group, likewise, no significant difference was found in positive, negative and overall deformation among subgroups (Table 3).
Table 2

Result of Kruskal-Wallis test of deformations in maxillary group

Chi-SquaredfAsymp. Sig.
MW group(+) deformaion0.49520.795
(−) deformation0.77820.678
Overall deformation0.51820.772
MD group(+) deformaion8.18220.017*
(−) deformation0.65320.721
Overall deformation7.25820.027*

* : statistically significant with 95% confident level.

Table 3

Result of Kruskal-Wallis test of deformations in mandibular group

Chi-SquaredfAsymp. Sig.
NW group(+) deformaion0.85120.654
(−) deformation3.51720.172
Overall deformation3.93020.140
ND group(+) deformaion2.83520.242
(−) deformation4.30420.116
Overall deformation4.34220.114

* : statistically significant with 95% confident level.

Table 4

Result of Mann whitney-U test in MD group

Compare groupsDeformationAsymp. Sig. (2-tailed)
MDa and MDb(+) deformaion0.025*
(−) deformation0.654
Overall deformation0.012*
MDb and MDc(+) deformaion0.009*
(−) deformation0.609
Overall deformation0.034*
MDa and MDc(+) deformaion0.749
(−) deformation0.406
Overall deformation0.797

* : statistically significant with 95% confident level.

The median, interquartile range, maximum and minimum values, of overall, positive, and negative deformation of denture bases for all groups were presented in Figure 5, and Figure 6.
Fig. 5

Box and whisker plots of overall, positive, and negative deformation of maxillary group.

Fig. 6

Box and whisker plots of overall, positive, and negative deformation of mandibular group.

DISCUSSION

It is obvious that the denture fabricated with a great care would be secured to patient's comfort, retention and stability of denture depending on the intimate contact between denture base and its basal tissue. However, to wear the denture longer and maintain good oral health, minimizing unexpected distortion of the denture is also an important factor as much as fabricating denture precisely. Thus, once the denture was fabricated precisely, maintaining of its accuracy would be a key factor for the longevity of denture. PMMA is the most popularly used denture base material, and heat curing resin has some advantage such as less deformation after fabrication and better color stability compared to self-cured resin. However, among various molding methods, no method is free from dimensional deformation due to polymerization contraction, heat contraction, stress deformation, and water absorption, and compression molding is still frequently applied to fabricating denture. Therefore, heat-cured resin and compression molding method was utilized in this study. Upon polymerization of resin, monomers contract as much as 21 vol%, so total contraction would be estimated about 5 to 7 vol% because monomers constitute 25% of the total volume.4 In the previous study, regarding the influence of cooling time, more linear deformation was observed in fast cooling group compared to slow cooling group. The reported reasons were, inadequate time to compensate contraction by water absorption, and lack of emission of stress inside the denture base caused during curing.18 Thus, this study was conducted after slowly cooling the denture bases for 24 hours in water. Many previous studies were conducted for evaluating the deformation occurred in the denture base and its fitting accuracy. However, most of them were studied using linear or cross-sectional analysis. Majority of previous studies employed optical microscope for measuring distance between landmark points of dentures, and some of those were conducted by using simple calipers.1920 These methods were limited for the overall deformation because measuring the two points was merely linear analysis. From the results and statistical analyses of this study, the fact that no significant deformation was observed during water storage resembles that of previous studies. Some previous studies reported expansion was occurred during water storage due to the water absorption. However, the meaning of contraction and expansion differs in this study. Expansion in the previous studies means increase in dimension, yet in this study, contraction was defined as the test surface being above the reference surface, and expansion was defined as being below the reference surface. In the study concerning the water absorption of acrylic resin, it was observed that 0.42% of expansion was observed over 3 weeks, and it takes about 17 days to be completely saturated.21 However, when water percentage was measured with digital scale and calculated with weight ratio, water percentage of 1.66 - 1.77 mass% was observed at deflasking, and water storage increased water percentage by only 0.46 - 0.50 mass%, indicating that high water percentage was already reached at deflasking.6 In the group of upper denture bases in water storage, no significant difference according to the storage period was observed. As the result from color-coded maps of overlapping week 0, 2, and 4, no significant changes could be observed. This could suggest that after the procedure of flasking, curing, deflasking, cooling, denture bases were already saturated with water that water storage after deflasking had no big influence on dimensional deformation since movement of water molecules is ignorable. In the group of upper denture bases in dry storage, week 0 and 2 showed significantly big difference in positive deformation (P = .026) and overall deformation (P = .011) compared to those of week 2 and 4, and week 0 and 4 also showed significant difference in positive deformation (P = .007) and overall deformation (P = .038) compared to those of week 2 and 4. This was the result of evaporation of water diffused into resin molecules, and more deformation took place during the first two weeks, indicating that most of the contraction occurred at that time. In addition, although insignificant, deformation was occurred during 4 weeks. It can be said that deformation increases by time. Upon observing deformation patterns with color-coded map, most contraction occurred at bilateral posterior buccal flange area somewhere between the week 0 - 2 and week 0 - 4, and as a result, the distance between the flanges decreased. Posterior palatal seal region tended to expand. The reasonthat significant deformation could not be seen in lower denture bases is thought that lower denture bases have broader surface than upper denture base, therefore enough water sorption could occur until deflasking. Deformation patterns could be observed more clearly with two-dimensional analysis. In upper denture bases, at the sagittal section of the image, no repeating deformation patterns were observed except for expansion at posterior palatal seal, but more clear and repeated bilateral contraction was seen at the frontal section. In this way, deformation of upper denture bases develops more frontally than sagittal. Nowadays, it is possible to analyze denture bases at a virtual space using digital scanner and computer software.16 To measure an object 3-dimensionally, contact and non-contact types are present, and basically, contact type has excellent accuracy, but is more appropriate to measure narrow area such as teeth, than to measure broad area such as denture bases. Optical laser scanner used in this study is 2-axis type with Z axis on rotating plate and Y axis at swing arm, and the scanned data was saved as STL file to digitalize. Digitalized data were analyzed by surface matching program. In other studies of analyzing discrepancies 3-dimensionally, performed surface overlap alignment after placing reference points at specific places, such as palatal portion of denture, alveolar ridge crest or cusp tip.1620 However, these techniques need assumption that no deformation occurs at the reference points during curing or storage, but there is no proof of it. Therefore, best-fit alignment can be utilized to minimize the errors of comparing and analyzing two denture bases, because this method uses scanned data of the whole surface.17 Through this study, the overall deformation and its pattern in cured upper and lower denture bases in dry and water storage was compared 3-dimensionally and analyzed in timely manner. To further evaluate the clinical effect, experiment protocol and program development is required to evaluate the adaptation of oral tissue and denture base. In addition, long-term and intensified studies are required to evaluate dimensional deformation during curing, deflasking and storage as they can be evaluated in 3-dimensional manner.

CONCLUSION

Following conclusions were attained from this study. During dry storage of upper denture bases, significant deformation was observed as time passed from week 0, 2, to 4. It occurred mostly in first two weeks, contraction was observed at bilateral posterior flange, and expansion at posterior palatal seal region. Although no significant differences were found in both storage of lower denture bases, obvious 3D deformation pattern were observed in dry storage denture bases, contraction at posterior buccal flange area and expansion at buccal shelf and retromolar pad. Most dimensional deformation presented within the first 2 weeks in all groups.
  14 in total

1.  History of resins in dentistry.

Authors:  F A Peyton
Journal:  Dent Clin North Am       Date:  1975-04

2.  Changes in dentures during storage in water and in service.

Authors:  J B WOELFEL; G C PAFFENBARGER; W T SWEENEY
Journal:  J Am Dent Assoc       Date:  1961-06       Impact factor: 3.634

3.  Dimensional stability of denture base resins.

Authors:  W E MOWERY; C L BURNS; G DICKSON; W T SWEENEY
Journal:  J Am Dent Assoc       Date:  1958-09       Impact factor: 3.634

4.  The influence of storage on dimensional changes in maxillary acrylic denture bases and the effect on tooth displacement.

Authors:  Rafael Leonardo Xediek Consani; Vanessa Lopes Monteiro; Marcelo Ferraz Mesquita; Simonides Consani
Journal:  Eur J Prosthodont Restor Dent       Date:  2011-09

5.  Moire topography for measuring the dimensional accuracy of resin complete denture bases.

Authors:  S Frejlich; J J Dirckx; C J Goodacre; M L Swartz; C J Andres
Journal:  Int J Prosthodont       Date:  1989 May-Jun       Impact factor: 1.681

6.  Effect of water storage on tooth displacement in maxillary complete dentures.

Authors:  Rafael Leonardo Xediek Consani; Marcelo Ferraz Mesquita; Simonides Consani; Lourenço Correr Sobrinho; Manoel Damião Sousa-Neto
Journal:  Braz Dent J       Date:  2006-05-02

7.  Water sorption by denture acrylic resin and consequent changes in vertical dimension.

Authors:  B Ristic; L Carr
Journal:  J Prosthet Dent       Date:  1987-12       Impact factor: 3.426

8.  Measuring procedure for the determination of the three-dimensional shape of dentures.

Authors:  A J de Gee; E C ten Harkel; C L Davidson
Journal:  J Prosthet Dent       Date:  1979-08       Impact factor: 3.426

9.  Temperature and dimensional changes in the two-stage processing technique for complete dentures.

Authors:  K C Yeung; T W Chow; R K Clark
Journal:  J Dent       Date:  1995-08       Impact factor: 4.379

10.  Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures.

Authors:  D M Wong; L Y Cheng; T W Chow; R K Clark
Journal:  J Prosthet Dent       Date:  1999-03       Impact factor: 3.426

View more
  4 in total

1.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

2.  Denture base adaptation, retention, and mechanical properties of BioHPP versus nano-alumina-modified polyamide resins.

Authors:  Radwa Mohsen Kamal Emera; Reham Mohammed Abdallah
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

Review 3.  Flexural Strength of CAD/CAM Denture Base Materials: Systematic Review and Meta-analysis of In-vitro Studies.

Authors:  Reem Abualsaud; Mohammed M Gad
Journal:  J Int Soc Prev Community Dent       Date:  2022-04-08

4.  Misfit of Complete Maxillary Dentures' Posterior Palatal Seal following Polymerisation with Four Different Autopolymerising Resins: An In Vitro Study.

Authors:  Simone Schiller; Elke Rustemeier; Dominik Kraus; Helmut Stark; Frauke Müller; Karl-Heinz Utz
Journal:  Materials (Basel)       Date:  2022-07-30       Impact factor: 3.748

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.