Literature DB >> 10050118

Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures.

D M Wong1, L Y Cheng, T W Chow, R K Clark.   

Abstract

STATEMENT OF PROBLEM: Acrylic resin complete dentures exhibit certain unavoidable dimensional changes. Processing shrinkage and expansion due to water uptake are 2 important aspects influencing dimensional accuracy.
PURPOSE: This study investigated linear dimensional changes and water sorption of dentures processed by dry and wet heat with different rates of cooling.
METHODS: Fine crosses marked on tinfoil inserts were placed at the incisive papilla and tuberosity regions of edentulous maxillary casts and incorporated into the dentures during polymerization by 3 processing techniques. A traveling microscope was used to measure the distances between the reference points to determine dimensional changes. Water uptake and content were determined by the mass changes of the dentures with an electronic balance. Data of linear dimensional change and water sorption were analyzed by multivariate analysis of variance and analysis of variance, respectively. Bonferroni simultaneous confidence intervals (95%) were applied for multiple comparison.
RESULTS: Dry heat-processed and water bath-processed acrylic resin dentures did not exhibit significant differences in shrinkage (0.42% to 0.58%) at water saturation. Amounts of water sorption of dentures processed by dry and wet heat (0.50 and 0.48 mass%, respectively) were not significantly different, and their associated expansion did not entirely compensate for the processing shrinkage. The initial water content of dry heat-processed dentures (1.77 mass%) was unexpectedly slightly higher than that of wet heat-processed dentures (1.68 mass%). The rate at which the dentures cooled did not affect their initial water content and subsequent water uptake.
CONCLUSIONS: Water uptake of dry and wet heat-processed acrylic resin dentures after deflasking was in both cases low, and the dentures did not reveal significant differences in shrinkage at water saturation. Air oven-processed and water bath-processed acrylic resin dentures show similar dimensional shrinkage at water saturation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10050118     DOI: 10.1016/s0022-3913(99)70273-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  19 in total

1.  Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures.

Authors:  Alaa'a M Salloum
Journal:  Saudi Dent J       Date:  2013-10-28

2.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

3.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

4.  The evaluation of water sorption/solubility on various acrylic resins.

Authors:  Suleyman Hakan Tuna; Filiz Keyf; Hasan Onder Gumus; Cengiz Uzun
Journal:  Eur J Dent       Date:  2008-07

5.  Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins.

Authors:  Ghazal Savabi; Omid Savabi; Badrosadat Dastgheib; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

6.  Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study.

Authors:  Duggineni Chalapathi Rao; N Kalavathy; H S Mohammad; A Hariprasad; C Ravi Kumar
Journal:  J Indian Prosthodont Soc       Date:  2015 Oct-Dec

7.  Three dimensional deformation of dry-stored complete denture base at room temperature.

Authors:  Seo-Ryeon Lim; Joon-Seok Lee
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

8.  Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture.

Authors:  Dae-Eun Jang; Ji-Young Lee; Hyun-Seon Jang; Jang-Jae Lee; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Effect of three investing materials on tooth movement during flasking procedure for complete denture construction.

Authors:  Alaa'a M Salloum
Journal:  Saudi Dent J       Date:  2015-12-02

10.  Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins.

Authors:  Neset Volkan Asar; Hamdi Albayrak; Turan Korkmaz; Ilser Turkyilmaz
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more