Literature DB >> 7629330

Temperature and dimensional changes in the two-stage processing technique for complete dentures.

K C Yeung1, T W Chow, R K Clark.   

Abstract

OBJECTIVES: This study concerned the temperature and linear dimensional change of heat-cured acrylic resin in the two-stage processing technique for complete dentures.
METHODS: Thermocouples were incorporated in the acrylic resin for recording temperatures. Measurements between reference marks were made by a high-resolution digital measuring microscope.
RESULTS: No increase in temperature associated with the exothermic nature of the polymerization reaction was recorded. The temperature of the resin followed the waterbath temperature closely. The temperatures recorded at various regions were in phase with each other. The total linear shrinkage of the base after two processing cycles was less than 1% and compares favourably with studies on the single-stage processing technique.
CONCLUSIONS: Temperature differential is excluded as a reason for the warpage of dentures. The dimensional changes of the denture base resulting from the two-stage processing technique cannot be considered to be of any clinical significance.

Mesh:

Substances:

Year:  1995        PMID: 7629330     DOI: 10.1016/0300-5712(95)91190-x

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  5 in total

1.  A Comparative Evaluation of the Linear Dimensional Changes of Two Different Commercially Available Heat Cure Acrylic Resins during Three Different Cooling Regimens.

Authors:  Abhishek Savirmath; Vandita Mishra
Journal:  J Clin Diagn Res       Date:  2016-11-01

2.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

3.  Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins.

Authors:  Ghazal Savabi; Omid Savabi; Badrosadat Dastgheib; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

4.  Three dimensional deformation of dry-stored complete denture base at room temperature.

Authors:  Seo-Ryeon Lim; Joon-Seok Lee
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

5.  A study of correlation between posterior palatal seal width and soft palatal angulation with palatal contour.

Authors:  Rupal J Shah; Sanjay B Lagdive; Divyeshkumar B Modi; Bhavyata Darji; Vedanshi A Amin; Ghanshyambhai C Patel
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun
  5 in total