Literature DB >> 27549660

The use of a "rim cutter" device and a flanged cup for improving the mantle of the acetabular component of a cemented Exeter total hip arthroplasty.

Jenaro Ángel Fernández-Valencia1, Xavier Gallart1, Guillem Bori1, Juan Miguel Rodríguez-Roiz2, Andreu Combalia1.   

Abstract

A retrospective study was performed to evaluate the cement mantle in two groups of patients treated with the acetabular components of cemented Exeter total hip arthroplasties (THAs). Two groups of 20 patients were compared: Group 1 received non-flanged acetabular cemented cups (Contemporary, Stryker) and Group 2 received flanged acetabular cemented cups (X3 Rim Fit, Stryker). Cups in Group 2 were implanted after using a rim cutter device. Group 2 showed better penetration of cement in zone 1 (10.76 mm compared with 2.93 mm; p = 0.008) and a thicker cement mantle in zone 1 (3.57 mm compared with 2.89 mm; p = 0.04). More cups in Group 2 had a cement mantle thickness less than 3 mm (30 % in Group 1 compared with 70 % in Group 2; p = 0.0039). No other radiological differences were observed. These results favor the use of a rim cutter device and flanged cup to improve the cement mantle for the acetabular components of cemented Exeter THAs. However, the improvements were less than expected. In view of the results of previous studies, further research is therefore needed to assess the value of this approach in improving the acetabular cement mantle.

Entities:  

Keywords:  Cement; Cement mantle; Cup; Rim cutter; Total hip arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27549660     DOI: 10.1007/s00590-016-1838-z

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  10 in total

1.  Acetabular cementing technique in THA--flanged versus unflanged cups, cadaver experiments.

Authors:  Dominik Parsch; Caroline Diehm; Sven Schneider; Andrew New; Steffen J Breusch
Journal:  Acta Orthop Scand       Date:  2004-06

2.  Does use of a "rim cutter" improve quality of cementation of the acetabular component of cemented exeter total hip arthroplasty?

Authors:  Jonathan L Conroy; Mayur Chawda; Rishi Kaushal; Sarah L Whitehouse; Ross W Crawford; Hugh English
Journal:  J Arthroplasty       Date:  2008-04-10       Impact factor: 4.757

3.  Benefits of using modern cementing techniques in the acetabulum: the Rim Cutter.

Authors:  Spyros N Darmanis; Matthew J W Hubble; Jonathan R Howell; Sarah L Whitehouse; A John Timperley
Journal:  J Orthop Surg (Hong Kong)       Date:  2012-12       Impact factor: 1.118

4.  Socket design and cement pressurisation in the Charnley low-friction arthroplasty.

Authors:  P Shelley; B M Wroblewski
Journal:  J Bone Joint Surg Br       Date:  1988-05

5.  Flow characteristics of acrylic bone cements.

Authors:  K L Markolf; J M Kabo; D W Stoller; S A Zager; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1984-03       Impact factor: 4.176

6.  Acetabular cement compactor. An experimental study of pressurization of cement in the acetabulum in total hip arthroplasty.

Authors:  I Oh; D B Merckx; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1983 Jul-Aug       Impact factor: 4.176

7.  The direct lateral approach to the hip.

Authors:  K Hardinge
Journal:  J Bone Joint Surg Br       Date:  1982

8.  Contemporary cementing technique and mortality during and after Exeter total hip arthroplasty.

Authors:  Rafael J Sierra; John A Timperley; Graham A Gie
Journal:  J Arthroplasty       Date:  2008-04-10       Impact factor: 4.757

9.  Comparison of flanged and unflanged acetabular cup design. An experimental study using ceramic and cadaveric acetabuli.

Authors:  Mette Ørskov; Saba Abdulghani; Ian McCarthy; Kjeld Søballe; Gunnar Flivik
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

10.  Comparison of cement pressurisation in flanged and unflanged acetabular cups.

Authors:  Rajarshi Bhattacharya; Fahad G Attar; Sarah Green; Andrew Port
Journal:  J Orthop Surg Res       Date:  2012-02-03       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.