Flow characteristics of acrylic bone cements.

K L Markolf, J M Kabo, D W Stoller, S A Zager, H C Amstutz.   

Abstract

Flow properties of Simplex, Zimmer Regular, Zimmer LVC, and Sulfix bone cements were measured as functions of time between two and five minutes after mixing. The mass flowrates measured for Zimmer Regular and Simplex were quite similar in the temperature range of 20.0 degrees -23.3 degrees. At 18.3 degrees Simplex had approximately double the flowrate of Zimmer Regular two minutes after mixing. The flowrate for LVC was approximately four times that measured for Zimmer Regular at 20.0 degrees. Sulfix displayed the greatest sensitivity of flowrate with temperature; at 18.3 degrees its flow characteristics were similar to those of LVC, and at 23.3 degrees it behaved more like Simplex and Zimmer Regular. All cements demonstrated substantial relative increases in flowrates with only slight increases in pressure; Sulfix was the most pressure sensitive. Set times for Zimmer, LVC, and Sulfix were virtually identical, ranging from a mean of 11 minutes (at 18.3 degrees) to 7.5 minutes (at 23.3 degrees). Simplex had considerably longer set times, averaging 15.8 minutes (at 18.3 degrees) and 9.4 minutes (at 23.3 degrees). Although Simplex demonstrated the greatest sensitivity of set time with temperature (almost double that measured for the other 3 cements), it did not show the greatest sensitivity of flowrate with temperature.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6697592

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

2.  In vitro experiments with an injection technique for cup fixation in total hip arthroplasty.

Authors:  J M Somville; P F Moldenaers; J C Mulier; J J Mewis
Journal:  Arch Orthop Trauma Surg       Date:  1987

3.  Influence of sterilization upon a range of properties of experimental bone cements.

Authors:  E J Harper; M Braden; W Bonfield; E Dingeldein; H Wahlig
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

4.  The use of a "rim cutter" device and a flanged cup for improving the mantle of the acetabular component of a cemented Exeter total hip arthroplasty.

Authors:  Jenaro Ángel Fernández-Valencia; Xavier Gallart; Guillem Bori; Juan Miguel Rodríguez-Roiz; Andreu Combalia
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-22

5.  Comparison of cement pressurisation in flanged and unflanged acetabular cups.

Authors:  Rajarshi Bhattacharya; Fahad G Attar; Sarah Green; Andrew Port
Journal:  J Orthop Surg Res       Date:  2012-02-03       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.