| Literature DB >> 27549084 |
Inyoung Song1, Jeong Geun Yi1, Jeong Hee Park1, Kyung Soo Lee2, Myung Jin Chung3,4.
Abstract
BACKGROUND: To compare the capability of lung nodule detection and characterization between dual-energy radiography with color-representation (DCR) and conventional gray scale chest radiography (GSR).Entities:
Keywords: Color radiography; Dual-energy subtraction radiography; Radiography
Mesh:
Year: 2016 PMID: 27549084 PMCID: PMC4994314 DOI: 10.1186/s12880-016-0155-7
Source DB: PubMed Journal: BMC Med Imaging ISSN: 1471-2342 Impact factor: 1.930
Fig 1Conventional gray scale radiography (GSR) and dual-energy radiography with color-representation (DCR) of a 60-year-old woman. a Conventional GSR image shows a nodular opacity in right lower lung zone (arrow). b DCR image shows distinct blue color of the nodular opacity (arrow) indicating calcified nodule. c Axial CT image shows a calcified granuloma in the right lower lobe (arrow)
Fig 2Conventional gray scale radiography (GSR) and dual-energy radiography with color-representation (DCR) of a 34-year-old man. a Conventional GSR image shows a nodular opacity in right lower lung zone (arrow). b DCR image shows distinct pink color of the nodular opacity (arrow) indicating non-calcified nodule. c Axial CT image shows a non-calcified nodule in the right lower lobe (arrow). This nodule was pathologically proved to be a sclerosing hemangioma
Fig 3Average free-response ROC curves for nodule detectability on dual-energy radiography with color-representation (DCR) and conventional gray scale radiography (GSR) images by each observer. FPF false positive fraction, LLF lesion localization fraction
Figure-of-merit values obtained from the JAFROC analysis for three radiologists in detecting lung nodules on conventional gray scale radiography (GSR) and dual-energy radiography with color-representation (DCR)
| Observer | Gray scale radiography | Dual-energy radiography with color-representation |
|---|---|---|
| 1 | 0.811 | 0.869 |
| 2 | 0.800 | 0.757 |
| 3 | 0.821 | 0.794 |
| Average | 0.811 | 0.807 |
The difference in figure-of-merit values between GSR and DCR imaging was not statistically significant (p = 0.928)
JAFROC jackknife alternative free-response receiver operating characteristic
Area under the receiver operating characteristic curve values obtained from MRMCROC method for three radiologists in predicting lung nodule calcification on conventional gray scale radiography (GSR) and dual-energy radiography with color-representation (DCR)
| Observer | Gray scale radiography | Dual-energy radiography with color-representation |
|---|---|---|
| 1 | 0.871 | 0.949 |
| 2 | 0.739 | 0.957 |
| 3 | 0.874 | 0.926 |
| Average | 0.828 | 0.944 |
The difference in area under the receiver operating characteristic curve values between GSR and DCR imaging was statistically significant (p = 0.044)
MRMCROC multi-reader, multi-case receiver operating characteristic