Literature DB >> 25848905

Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent.

Alexander Radbruch1, Lukas D Weberling, Pascal J Kieslich, Oliver Eidel, Sina Burth, Philipp Kickingereder, Sabine Heiland, Wolfgang Wick, Heinz-Peter Schlemmer, Martin Bendszus.   

Abstract

PURPOSE: To compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) and the globus pallidus (GP) to those of other structures on unenhanced T1-weighted magnetic resonance (MR) images between linear and macrocyclic gadolinium-based contrast agents (GBCAs).
MATERIALS AND METHODS: The study was approved by the ethical committee of the University of Heidelberg (reference no. S-324/2014). Owing to the retrospective character of the study, the ethical committee did not require any written informed consent. Two groups of 50 patients who underwent at least six consecutive MR imaging examinations with the exclusive use of either a linear GBCA (gadopentetate dimeglumine) or a macrocyclic GBCA (gadoterate meglumine) were analyzed retrospectively. The difference in mean SI ratios of DN to pons and GP to thalamus on unenhanced T1-weighted images from the last and first examinations was calculated. One-sample and independent-sample t tests were used to assess the difference in SI ratios for both groups, and regression analysis was performed to account for potential confounders.
RESULTS: The SI ratio difference in the linear group was greater than 0 (mean DN difference ± standard deviation, 0.0407 ± 0.0398 [P < .001]; GP, 0.0287 ± 0.0275 [P < .001]) and significantly larger (DN, P < .001 and standardized difference of 1.16; GP, P < .001 and standardized difference of 0.81) than that in the macrocyclic group, which did not differ from 0 (DN, 0.0016 ± 0.0266 [P = .680]; GP, 0.0031 ± 0.0354 [P = .538]). The SI ratio difference between the last and first examinations for the DN remained significantly different between the two groups in the regression analysis (P < .001).
CONCLUSION: This study indicates that an SI increase in the DN and GP on T1-weighted images is caused by serial application of the linear GBCA gadopentetate dimeglumine but not by the macrocyclic GBCA gadoterate meglumine. Clinical implications of this observation remain unclear. RSNA, 2015

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25848905     DOI: 10.1148/radiol.2015150337

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  179 in total

Review 1.  The biological fate of gadolinium-based MRI contrast agents: a call to action for bioinorganic chemists.

Authors:  Mariane Le Fur; Peter Caravan
Journal:  Metallomics       Date:  2019-02-20       Impact factor: 4.526

2.  Reply to Letter to the Editor re: Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: Correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol.

Authors:  Dragan A Stojanov
Journal:  Eur Radiol       Date:  2015-09-21       Impact factor: 5.315

Review 3.  Gadolinium-based contrast agents: did we miss something in the last 25 years?

Authors:  Bruno Beomonte Zobel; Carlo Cosimo Quattrocchi; Yuri Errante; Rosario Francesco Grasso
Journal:  Radiol Med       Date:  2015-12-26       Impact factor: 3.469

4.  Spine MRI in Spontaneous Intracranial Hypotension for CSF Leak Detection: Nonsuperiority of Intrathecal Gadolinium to Heavily T2-Weighted Fat-Saturated Sequences.

Authors:  T Dobrocky; A Winklehner; P S Breiding; L Grunder; G Peschi; L Häni; P J Mosimann; M Branca; J Kaesmacher; P Mordasini; A Raabe; C T Ulrich; J Beck; J Gralla; E I Piechowiak
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-18       Impact factor: 3.825

5.  Gadolinium deposition in the brain: association with various GBCAs using a generalized additive model.

Authors:  Sohi Bae; Ho-Joon Lee; Kyunghwa Han; Yae-Won Park; Yoon Seong Choi; Sung Soo Ahn; Jinna Kim; Seung-Koo Lee
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

6.  Nonhomogeneous Gadolinium Retention in the Cerebral Cortex after Intravenous Administration of Gadolinium-based Contrast Agent in Rats and Humans.

Authors:  Olga Minaeva; Ning Hua; Erich S Franz; Nicola Lupoli; Asim Z Mian; Chad W Farris; Audrey M Hildebrandt; Patrick T Kiernan; Laney E Evers; Allison D Griffin; Xiuping Liu; Sarah E Chancellor; Katharine J Babcock; Juliet A Moncaster; Hernan Jara; Victor E Alvarez; Bertrand R Huber; Ali Guermazi; Lawrence L Latour; Ann C McKee; Jorge A Soto; Stephan W Anderson; Lee E Goldstein
Journal:  Radiology       Date:  2019-11-26       Impact factor: 11.105

Review 7.  Gadolinium-based contrast agents in pediatric magnetic resonance imaging.

Authors:  Eric M Gale; Peter Caravan; Anil G Rao; Robert J McDonald; Matthew Winfeld; Robert J Fleck; Michael S Gee
Journal:  Pediatr Radiol       Date:  2017-04-13

8.  Signal intensity change on unenhanced T1-weighted images in dentate nucleus following gadobenate dimeglumine in patients with and without previous multiple administrations of gadodiamide.

Authors:  Joana Ramalho; Richard C Semelka; Mamdoh AlObaidy; Miguel Ramalho; Renato H Nunes; Mauricio Castillo
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

Review 9.  Gadolinium-based contrast agents in children.

Authors:  Michael N Rozenfeld; Daniel J Podberesky
Journal:  Pediatr Radiol       Date:  2018-08-04

10.  Physicians' awareness of gadolinium retention and MRI timing practices in the longitudinal management of pituitary tumors: a "Pituitary Society" survey.

Authors:  Lisa B Nachtigall; Niki Karavitaki; Katja Kiseljak-Vassiliades; Luma Ghalib; Hidenori Fukuoka; Luis V Syro; Daniel Kelly; Maria Fleseriu
Journal:  Pituitary       Date:  2019-02       Impact factor: 4.107

View more