Literature DB >> 2752811

Skin color and ear oximetry.

A L Ries1, L M Prewitt, J J Johnson.   

Abstract

Measurements of arterial blood oxygen saturation from two ear oximeters were compared with 655 simultaneously drawn arterial blood samples in 187 patients grouped by skin color quantified by the Munsell color system. Technical problems including warning lights and messages with the two ear oximeters were recorded. There were significantly more technical problems in patients with the darkest skin color associated with inability to obtain a reading or warning message indicating poor tissue penetration of the signal (18 and 15 percent vs 1 percent). When readings could be obtained, the ear oximetry readings were found to be slightly less accurate in the darker patient groups. These findings suggest that dark skin color may affect the performance and accuracy of ear oximeters, including the newer type of pulse oximeters.

Entities:  

Mesh:

Year:  1989        PMID: 2752811     DOI: 10.1378/chest.96.2.287

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  16 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

2.  The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.

Authors:  Elizabeth E Foglia; Robin K Whyte; Aasma Chaudhary; Antonio Mott; Jodi Chen; Kathleen J Propert; Barbara Schmidt
Journal:  J Pediatr       Date:  2016-12-09       Impact factor: 4.406

3.  Monte Carlo analysis of optical heart rate sensors in commercial wearables: the effect of skin tone and obesity on the photoplethysmography (PPG) signal.

Authors:  Tananant Boonya-Ananta; Andres J Rodriguez; V N Du Le; Jessica C Ramella-Roman
Journal:  Biomed Opt Express       Date:  2021-11-10       Impact factor: 3.732

4.  Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom.

Authors:  Ali Afshari; Rolf B Saager; David Burgos; William C Vogt; Jianting Wang; Gonzalo Mendoza; Sandy Weininger; Kung-Bin Sung; Anthony J Durkin; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

5.  Pulse Oximetry: The Working Principle, Signal Formation, and Applications.

Authors:  Timo Leppänen; Samu Kainulainen; Henri Korkalainen; Saara Sillanmäki; Antti Kulkas; Juha Töyräs; Sami Nikkonen
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

6.  Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study.

Authors:  Valeria S M Valbuena; Sarah Seelye; Michael W Sjoding; Thomas S Valley; Robert P Dickson; Steven E Gay; Dru Claar; Hallie C Prescott; Theodore J Iwashyna
Journal:  BMJ       Date:  2022-07-06

7.  Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms.

Authors:  Sean Bae; Silviu Borac; Yunus Emre; Jonathan Wang; Jiang Wu; Mehr Kashyap; Si-Hyuck Kang; Liwen Chen; Melissa Moran; Julie Cannon; Eric S Teasley; Allen Chai; Yun Liu; Neal Wadhwa; Michael Krainin; Michael Rubinstein; Alejandra Maciel; Michael V McConnell; Shwetak Patel; Greg S Corrado; James A Taylor; Jiening Zhan; Ming Jack Po
Journal:  Commun Med (Lond)       Date:  2022-04-12

8.  Influence of Sex, BMI, and Skin Color on the Accuracy of Non-Invasive Cuffless Photoplethysmography-Based Blood Pressure Measurements.

Authors:  Dean Nachman; Arik Eisenkraft; Nir Goldstein; Arik Ben-Ishay; Meir Fons; Roei Merin; Yftach Gepner
Journal:  Front Physiol       Date:  2022-06-29       Impact factor: 4.755

9.  Correlation Between PaO2/FIO2 and Peripheral Capillary Oxygenation/FIO2 in Burned Children With Smoke Inhalation Injury.

Authors:  Janos Cambiaso-Daniel; Charles D Voigt; Eric Rivas; Gabriel Hundeshagen; Omar Nunez-Lopez; Lars-Peter Kamolz; Michaela Sljivich; Linda E Sousse; David N Herndon; Oscar E Suman; Michael P Kinsky; Ronald P Mlcak
Journal:  Pediatr Crit Care Med       Date:  2017-10       Impact factor: 3.624

10.  The accuracy of the Biox 3700 pulse oximeter in patients receiving vasoactive therapy.

Authors:  J Ibáñez; J Velasco; J M Raurich
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.