Literature DB >> 36217086

Pulse Oximetry: The Working Principle, Signal Formation, and Applications.

Timo Leppänen1,2,3, Samu Kainulainen4,5, Henri Korkalainen4,5, Saara Sillanmäki5, Antti Kulkas4,6, Juha Töyräs4,7,8, Sami Nikkonen4,5.   

Abstract

Pulse oximeters are routinely used in various medical-grade and consumer-grade applications. They can be used to estimate, for example, blood oxygen saturation, autonomic nervous system activity and cardiac function, blood pressure, sleep quality, and recovery through the recording of photoplethysmography signal. Medical-grade devices often record red and infra-red light-based photoplethysmography signals while smartwatches and other consumer-grade devices usually rely on a green light. At its simplest, a pulse oximeter can consist of one or two photodiodes and a photodetector attached, for example, a fingertip or earlobe. These sensors are used to record light absorption in a medium as a function of time. This time-varying absorption information is used to form a photoplethysmography signal. In this chapter, we discuss the working principles of pulse oximeters and the formation of the photoplethysmography signal. We will further discuss the advantages and disadvantages of pulse oximeters, which kind of applications exist in the medical field, and how pulse oximeters are utilized in daily health monitoring.
© 2022. The Author(s), under exclusive license to Springer Nature Switzerland AG.

Entities:  

Keywords:  Application; Oxygen saturation; Photoplethysmography; Pulse oximetry

Mesh:

Substances:

Year:  2022        PMID: 36217086     DOI: 10.1007/978-3-031-06413-5_12

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   3.650


  53 in total

1.  Hemoglobin covalently bridged across the polyphoshate binding site.

Authors:  R Benesch; R E Benesch; S Yung; R Edalji
Journal:  Biochem Biophys Res Commun       Date:  1975-04-21       Impact factor: 3.575

2.  Effect of skin pigmentation on pulse oximetry accuracy in the emergency department.

Authors:  J N Adler; L A Hughes; R Vivilecchia; C A Camargo
Journal:  Acad Emerg Med       Date:  1998-10       Impact factor: 3.451

3.  Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry.

Authors:  S J Barker; K K Tremper; J Hyatt
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

4.  Effects of skin pigmentation on pulse oximeter accuracy at low saturation.

Authors:  Philip E Bickler; John R Feiner; John W Severinghaus
Journal:  Anesthesiology       Date:  2005-04       Impact factor: 7.892

5.  Automated Screening of Children With Obstructive Sleep Apnea Using Nocturnal Oximetry: An Alternative to Respiratory Polygraphy in Unattended Settings.

Authors:  Daniel Álvarez; María L Alonso-Álvarez; Gonzalo C Gutiérrez-Tobal; Andrea Crespo; Leila Kheirandish-Gozal; Roberto Hornero; David Gozal; Joaquín Terán-Santos; Félix Del Campo
Journal:  J Clin Sleep Med       Date:  2017-05-15       Impact factor: 4.062

6.  Accuracy of pulse oximetry in pigmented patients.

Authors:  P A Bothma; G M Joynt; J Lipman; H Hon; B Mathala; J Scribante; J Kromberg
Journal:  S Afr Med J       Date:  1996-05

7.  Computerized photo-plethysmography of the finger.

Authors:  V F Blanc; M Haig; M Troli; B Sauvé
Journal:  Can J Anaesth       Date:  1993-03       Impact factor: 5.063

8.  The hypoxic burden of sleep apnoea predicts cardiovascular disease-related mortality: the Osteoporotic Fractures in Men Study and the Sleep Heart Health Study.

Authors:  Ali Azarbarzin; Scott A Sands; Katie L Stone; Luigi Taranto-Montemurro; Ludovico Messineo; Philip I Terrill; Sonia Ancoli-Israel; Kristine Ensrud; Shaun Purcell; David P White; Susan Redline; Andrew Wellman
Journal:  Eur Heart J       Date:  2019-04-07       Impact factor: 29.983

9.  The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous PO2.

Authors:  S J Barker; K K Tremper
Journal:  Anesthesiology       Date:  1987-05       Impact factor: 7.892

Review 10.  Fluorescent light interferes with pulse oximetry.

Authors:  D Amar; J Neidzwski; A Wald; A D Finck
Journal:  J Clin Monit       Date:  1989-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.