Automated lesion annotation during pulmonary vein isolation: influence on acute isolation rates and lesion characteristics.

Stefan Asbach1, Corinna Lang2, Luca Trolese2, Christoph Bode2, Fabienne Schluermann2.   

Abstract

PURPOSE: Recovery of pulmonary vein (PV) conduction is a common mechanism of atrial fibrillation recurrence after PV isolation (PVI), underscoring the need for durable lesion formation. We aimed to evaluate the utility of an automated lesion annotation algorithm (ALAA) on acute isolation rates and resulting lesion characteristics.
METHODS: Fifty patients underwent PVI using a contact force (CF) sensing catheter and ALAA. Single antral circles around ipsilateral PVs were performed with ALAA-1 settings including catheter stability (range of motion ≤2 mm, duration >10 s). Target CF was 10-20 g but not part of ALAA-1 settings. If PV conduction persisted after circle completion, force over time was added to automated settings (ALAA-2). Emerging gaps were subsequently ablated, followed by re-assessment for PVI.
RESULTS: ALAA-1 isolated 70 % of the left and 78 % of the right PVs using 756.3 ± 212.3 s (left) and 737.1 ± 145.9 s (right) of energy delivery. ALAA-2 settings identified 29 gaps in previously unisolated PVs, closure significantly increased isolation rates to 88 % of the left and 96 % of the right PVs with additional 325.4 ± 354.1 s (left) and 266.8 ± 279.5 s (right) of energy delivery (p = 0.001). Lesion characteristics significantly differed between ALAA-1 (n = 3521 lesions) and ALAA-2 (n = 3037 lesions) settings, and between isolated and non-isolated PV segments, particularly with respect to CF. Interlesion distances with ALAA-2 were significantly longer in the left superior, left superior-anterior, and right superior-posterior segments when compared to ALAA-1.
CONCLUSIONS: Settings of an ALAA affect lesion characteristics reveal areas of insufficient lesion formation and influence acute effectiveness of PVI. Combination of CF and stability shows superior performance over stability alone.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Automated lesion annotation; Contact force

Mesh:

Year:  2016        PMID: 27511472     DOI: 10.1007/s10840-016-0173-y

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  20 in total

1.  Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.

Authors:  Jason G Andrade; George Monir; Scott J Pollak; Paul Khairy; Marc Dubuc; Denis Roy; Mario Talajic; Marc Deyell; Léna Rivard; Bernard Thibault; Peter G Guerra; Stanley Nattel; Laurent Macle
Journal:  Heart Rhythm       Date:  2014-07-25       Impact factor: 6.343

2.  In vivo contact force measurements and correlation with left atrial anatomy during catheter ablation of atrial fibrillation.

Authors:  Fabienne Schluermann; Tobias Krauss; Juergen Biermann; Maximilian Hartmann; Luca Trolese; Gregor Pache; Christoph Bode; Stefan Asbach
Journal:  Europace       Date:  2015-03-04       Impact factor: 5.214

3.  Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.

Authors:  Andrea Natale; Vivek Y Reddy; George Monir; David J Wilber; Bruce D Lindsay; H Thomas McElderry; Charan Kantipudi; Moussa C Mansour; Daniel P Melby; Douglas L Packer; Hiroshi Nakagawa; Baohui Zhang; Robert B Stagg; Lee Ming Boo; Francis E Marchlinski
Journal:  J Am Coll Cardiol       Date:  2014-08-19       Impact factor: 24.094

4.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

5.  Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size.

Authors:  Atsushi Ikeda; Hiroshi Nakagawa; Hendrik Lambert; Dipen C Shah; Edouard Fonck; Aude Yulzari; Tushar Sharma; Jan V Pitha; Ralph Lazzara; Warren M Jackman
Journal:  Circ Arrhythm Electrophysiol       Date:  2014-11-07

6.  Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique.

Authors:  Feifan Ouyang; Matthias Antz; Sabine Ernst; Hitoshi Hachiya; Hercules Mavrakis; Florian T Deger; Anselm Schaumann; Julian Chun; Peter Falk; Detlef Hennig; Xingpeng Liu; Dietmar Bänsch; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-12-27       Impact factor: 29.690

7.  Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

Authors:  Aravinda Thiagalingam; Andre D'Avila; Lori Foley; J Luis Guerrero; Hendrik Lambert; Giovanni Leo; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2010-02-01

8.  Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction.

Authors:  Atul Verma; Fethi Kilicaslan; Ennio Pisano; Nassir F Marrouche; Raffaele Fanelli; Johannes Brachmann; Jens Geunther; Domenico Potenza; David O Martin; Jennifer Cummings; J David Burkhardt; Walid Saliba; Robert A Schweikert; Andrea Natale
Journal:  Circulation       Date:  2005-08-02       Impact factor: 29.690

9.  Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.

Authors:  Chan-Il Park; Heiko Lehrmann; Cornelius Keyl; Reinhold Weber; Jochen Schiebeling; Juergen Allgeier; Patrick Schurr; Ashok Shah; Franz-Josef Neumann; Thomas Arentz; Amir S Jadidi
Journal:  J Cardiovasc Electrophysiol       Date:  2014-04-02

10.  Prospective European survey on atrial fibrillation ablation: clinical characteristics of patients and ablation strategies used in different countries.

Authors:  Sakis Themistoclakis; Antonio Raviele; Paolo China; Carlo Pappone; Roberto De Ponti; Amiran Revishvili; Etienne Aliot; Karl-Heinz Kuck; Per Ivar Hoff; Dipen Shah; Jesús Almendral; Antonis S Manolis; Gian-Battista Chierchia; Ali Oto; Radu G Vatasescu; Matjaz Sinkovec; Riccardo Cappato
Journal:  J Cardiovasc Electrophysiol       Date:  2014-07-08
View more
  2 in total

1.  Gains in Paroxysmal Atrial Fibrillation Ablation Using a Standardized Workflow to Optimize Contact Force Technologies.

Authors:  Jose Osorio; Tina D Hunter; Rosemary S Bubien; Anil Rajendra; Joaquin Arciniegas; Gustavo Morales
Journal:  J Atr Fibrillation       Date:  2018-12-31

2.  Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system.

Authors:  Hyoung-Seob Park; In-Cheol Kim; Yun-Kyeong Cho; Hyuck-Jun Yoon; Hyungseop Kim; Chang-Wook Nam; Seongwook Han; Seung-Ho Hur; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  J Arrhythm       Date:  2018-04-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.