Literature DB >> 27488507

Image quality and dose differences caused by vendor-specific image processing of neonatal radiographs.

William F Sensakovic1, M Cody O'Dell2, Haley Letter2, Nathan Kohler2, Baiywo Rop2, Jane Cook2, Gregory Logsdon2, Laura Varich2.   

Abstract

BACKGROUND: Image processing plays an important role in optimizing image quality and radiation dose in projection radiography. Unfortunately commercial algorithms are black boxes that are often left at or near vendor default settings rather than being optimized.
OBJECTIVE: We hypothesize that different commercial image-processing systems, when left at or near default settings, create significant differences in image quality. We further hypothesize that image-quality differences can be exploited to produce images of equivalent quality but lower radiation dose.
MATERIALS AND METHODS: We used a portable radiography system to acquire images on a neonatal chest phantom and recorded the entrance surface air kerma (ESAK). We applied two image-processing systems (Optima XR220amx, by GE Healthcare, Waukesha, WI; and MUSICA(2) by Agfa HealthCare, Mortsel, Belgium) to the images. Seven observers (attending pediatric radiologists and radiology residents) independently assessed image quality using two methods: rating and matching. Image-quality ratings were independently assessed by each observer on a 10-point scale. Matching consisted of each observer matching GE-processed images and Agfa-processed images with equivalent image quality. A total of 210 rating tasks and 42 matching tasks were performed and effective dose was estimated.
RESULTS: Median Agfa-processed image-quality ratings were higher than GE-processed ratings. Non-diagnostic ratings were seen over a wider range of doses for GE-processed images than for Agfa-processed images. During matching tasks, observers matched image quality between GE-processed images and Agfa-processed images acquired at a lower effective dose (11 ± 9 μSv; P < 0.0001).
CONCLUSION: Image-processing methods significantly impact perceived image quality. These image-quality differences can be exploited to alter protocols and produce images of equivalent image quality but lower doses. Those purchasing projection radiography systems or third-party image-processing software should be aware that image processing can significantly impact image quality when settings are left near default values.

Keywords:  Chest; Image processing; Image quality; Neonate; Radiation dose; Radiography

Mesh:

Year:  2016        PMID: 27488507     DOI: 10.1007/s00247-016-3663-2

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  16 in total

1.  Diagnostic image quality of mobile neonatal chest X-rays and the radiation exposure incurred.

Authors:  A Lowe; A Finch; D Boniface; R Chaudhuri; J Shekhdar
Journal:  Br J Radiol       Date:  1999-01       Impact factor: 3.039

2.  The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams--a white paper conference.

Authors:  Charles E Willis; Thomas L Slovis
Journal:  AJR Am J Roentgenol       Date:  2005-02       Impact factor: 3.959

3.  Estimation of radiation dose during diagnostic X-ray examinations of newborn babies and 1-year-old infants.

Authors:  A Brindhaban; C U Eze
Journal:  Med Princ Pract       Date:  2006       Impact factor: 1.927

4.  Effects of dose reduction on digital chest imaging using a selenium detector: a study of detecting simulated diffuse interstitial pulmonary disease.

Authors:  H P van Heesewijk; Y van der Graaf; J C de Valois; M A Feldberg
Journal:  AJR Am J Roentgenol       Date:  1996-08       Impact factor: 3.959

5.  Improved control of image optical density with low-dose digital and conventional radiography in bedside imaging.

Authors:  C M Schaefer; R E Greene; J W Oestmann; J M Kamalsky; D A Hall; H J Llewellyn; C L Robertson; J T Rhea; H Rosenthal; J R Rubens
Journal:  Radiology       Date:  1989-12       Impact factor: 11.105

Review 6.  [New analog and digital imaging techniques for chest diagnosis--principles--clinical value--economics].

Authors:  H P Busch; K J Lehmann; M Georgi
Journal:  Aktuelle Radiol       Date:  1993-01

7.  Use of medical imaging procedures with ionizing radiation in children: a population-based study.

Authors:  Adam L Dorfman; Reza Fazel; Andrew J Einstein; Kimberly E Applegate; Harlan M Krumholz; Yongfei Wang; Emmanuel Christodoulou; Jersey Chen; Ramon Sanchez; Brahmajee K Nallamothu
Journal:  Arch Pediatr Adolesc Med       Date:  2011-01-03

8.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

9.  Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease.

Authors:  Lucia J M Kroft; Wouter J H Veldkamp; Bart J A Mertens; Mireille V Boot; Jacob Geleijns
Journal:  AJR Am J Roentgenol       Date:  2005-08       Impact factor: 3.959

10.  Cumulative effective doses delivered by radiographs to preterm infants in a neonatal intensive care unit.

Authors:  Jean Donadieu; Abdelkrim Zeghnoun; Candice Roudier; Carlo Maccia; Phillipe Pirard; Christine André; Catherine Adamsbaum; Gabriel Kalifa; Paul Legmann; Pierre-Henri Jarreau
Journal:  Pediatrics       Date:  2006-03       Impact factor: 7.124

View more
  4 in total

1.  Visual grading analysis of digital neonatal chest phantom X-ray images: Impact of detector type, dose and image processing on image quality.

Authors:  M H Smet; L Breysem; E Mussen; H Bosmans; N W Marshall; L Cockmartin
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

2.  Ultrasound Images under an Optimized Image Processing Algorithm in Guiding the Neurological Safety of Resection of Lumbar Disc Nucleus Pulposus in Spinal Surgery.

Authors:  Kaiwei Yin; Yehai Chen; Shuying Gao
Journal:  Comput Math Methods Med       Date:  2022-06-02       Impact factor: 2.809

3.  An anthropomorphic phantom representing a prematurely born neonate for digital x-ray imaging using 3D printing: Proof of concept and comparison of image quality from different systems.

Authors:  Nikolaus Irnstorfer; Ewald Unger; Azadeh Hojreh; Peter Homolka
Journal:  Sci Rep       Date:  2019-10-07       Impact factor: 4.379

4.  Advances in multiscale image processing and its effects on image quality in skeletal radiography.

Authors:  Susan Notohamiprodjo; K M Roeper; F G Mueck; D Maxien; F Wanninger; B Hoberg; L Verstreepen; K M Treitl; F Fischer; O Peschel; S Wirth
Journal:  Sci Rep       Date:  2022-03-18       Impact factor: 4.379

  4 in total