Literature DB >> 27484131

Analog filtering methods improve leading edge timing performance of multiplexed SiPMs.

M F Bieniosek1, J W Cates, A M Grant, C S Levin.   

Abstract

Multiplexing many SiPMs to a single readout channel is an attractive option to reduce the readout complexity of high performance time of flight (TOF) PET systems. However, the additional dark counts and shaping from each SiPM cause significant baseline fluctuations in the output waveform, degrading timing measurements using a leading edge threshold. This work proposes the use of a simple analog filtering network to reduce the baseline fluctuations in highly multiplexed SiPM readouts. With 16 SiPMs multiplexed, the FWHM coincident timing resolution for single [Formula: see text] mm LYSO crystals was improved from 401  ±  4 ps without filtering to 248  ±  5 ps with filtering. With 4 SiPMs multiplexed, using an array of [Formula: see text] mm LFS crystals the mean time resolution was improved from 436  ±  6 ps to 249  ±  2 ps. Position information was acquired with a novel binary positioning network. All experiments were performed at room temperature with no active temperature regulation. These results show a promising technique for the construction of high performance multiplexed TOF PET readout systems using analog leading edge timing pickoff.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27484131      PMCID: PMC5116436          DOI: 10.1088/0031-9155/61/16/N427

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Time-of-flight positron emission tomography: status relative to conventional PET.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1983-01       Impact factor: 10.057

2.  High-performance electronics for time-of-flight PET systems.

Authors:  W-S Choong; Q Peng; C Q Vu; B T Turko; W W Moses
Journal:  J Instrum       Date:  2013-01-01       Impact factor: 1.415

3.  Achieving fast timing performance with multiplexed SiPMs.

Authors:  M F Bieniosek; J W Cates; C S Levin
Journal:  Phys Med Biol       Date:  2016-03-17       Impact factor: 3.609

  3 in total
  5 in total

1.  Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers.

Authors:  Joshua W Cates; Matthew F Bieniosek; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-23

2.  A multiplexed TOF and DOI capable PET detector using a binary position sensitive network.

Authors:  M F Bieniosek; J W Cates; C S Levin
Journal:  Phys Med Biol       Date:  2016-10-14       Impact factor: 3.609

3.  Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines.

Authors:  Heejong Kim; Chien-Min Kao; Yuexuan Hua; Qingguo Xie; Chin-Tu Chen
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-01-13

4.  Performance assessment of the 2 γpositronium imaging with the total-body PET scanners.

Authors:  P Moskal; D Kisielewska; R Y Shopa; Z Bura; J Chhokar; C Curceanu; E Czerwiński; M Dadgar; K Dulski; J Gajewski; A Gajos; M Gorgol; R Del Grande; B C Hiesmayr; B Jasińska; K Kacprzak; A Kamińska; Ł Kapłon; H Karimi; G Korcyl; P Kowalski; N Krawczyk; W Krzemień; T Kozik; E Kubicz; P Małczak; M Mohammed; Sz Niedźwiecki; M Pałka; M Pawlik-Niedźwiecka; M Pędziwiatr; L Raczyński; J Raj; A Ruciński; S Sharma; S Shivani; M Silarski; M Skurzok; E Ł Stępień; S Vandenberghe; W Wiślicki; B Zgardzińska
Journal:  EJNMMI Phys       Date:  2020-06-30

Review 5.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Authors:  Haewook Park; Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-07-16
  5 in total