Literature DB >> 27479721

Dose Specification for NRG Radiation Therapy Trials.

David J Gladstone1, Stephen F Kry2, Ying Xiao3, Indrin J Chetty4.   

Abstract

Entities:  

Mesh:

Year:  2016        PMID: 27479721      PMCID: PMC5637531          DOI: 10.1016/j.ijrobp.2016.03.044

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


× No keyword cloud information.
  6 in total

1.  Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations.

Authors:  J V Siebers; P J Keall; A E Nahum; R Mohan
Journal:  Phys Med Biol       Date:  2000-04       Impact factor: 3.609

2.  Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations.

Authors:  Tommy Knöös; Elinore Wieslander; Luca Cozzi; Carsten Brink; Antonella Fogliata; Dirk Albers; Håkan Nyström; Søren Lassen
Journal:  Phys Med Biol       Date:  2006-10-24       Impact factor: 3.609

Review 3.  Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

Authors:  Indrin J Chetty; Bruce Curran; Joanna E Cygler; John J DeMarco; Gary Ezzell; Bruce A Faddegon; Iwan Kawrakow; Paul J Keall; Helen Liu; C M Charlie Ma; D W O Rogers; Jan Seuntjens; Daryoush Sheikh-Bagheri; Jeffrey V Siebers
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

4.  Dose specification for radiation therapy: dose to water or dose to medium?

Authors:  C-M Ma; Jinsheng Li
Journal:  Phys Med Biol       Date:  2011-04-20       Impact factor: 3.609

5.  3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC).

Authors:  I Kawrakow; M Fippel; K Friedrich
Journal:  Med Phys       Date:  1996-04       Impact factor: 4.071

6.  Dose to 'water-like' media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate.

Authors:  Pedro Andreo
Journal:  Phys Med Biol       Date:  2014-12-12       Impact factor: 3.609

  6 in total
  10 in total

1.  Dose specification for hippocampal sparing whole brain radiotherapy (HS WBRT): considerations from the UK HIPPO trial QA programme.

Authors:  Daniel Megias; Mark Phillips; Laura Clifton-Hadley; Elizabeth Harron; David J Eaton; Paul Sanghera; Gillian Whitfield
Journal:  Br J Radiol       Date:  2017-01-06       Impact factor: 3.039

2.  Dose calculation and reporting with a linear Boltzman transport equation solver in vertebral SABR.

Authors:  Nicholas Hardcastle; Jeremy Hughes; Shankar Siva; Tomas Kron
Journal:  Phys Eng Sci Med       Date:  2021-11-23

3.  Dose accuracy improvement on head and neck VMAT treatments by using the Acuros algorithm and accurate FFF beam calibration.

Authors:  Guadalupe Martin-Martin; Stefan Walter; Eduardo Guibelalde
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25

4.  Clinical implementation and evaluation of the Acuros dose calculation algorithm.

Authors:  Chenyu Yan; Anthony G Combine; Greg Bednarz; Ronald J Lalonde; Bin Hu; Kathy Dickens; Raymond Wynn; Daniel C Pavord; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2017-08-20       Impact factor: 2.102

5.  Tuning of AcurosXB source size setting for small intracranial targets.

Authors:  Stephen J Gardner; Siming Lu; Chang Liu; Ning Wen; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2017-05-04       Impact factor: 2.102

6.  Validation of a GPU-Based 3D dose calculator for modulated beams.

Authors:  Saeed Ahmed; Dylan Hunt; Jeff Kapatoes; Robert Hayward; Geoffrey Zhang; Eduardo G Moros; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2017-03-29       Impact factor: 2.102

7.  Dose to medium in head and neck radiotherapy: Clinical implications for target volume metrics.

Authors:  Nicholas Hardcastle; Atousa Montaseri; Jenny Lydon; Tomas Kron; Glen Osbourne; Georgina Casswell; David Taylor; Lisa Hall; Lachlan McDowell
Journal:  Phys Imaging Radiat Oncol       Date:  2019-09-24

8.  Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning.

Authors:  Vladimir Feygelman; Kujtim Latifi; Mark Bowers; Kevin Greco; Eduardo G Moros; Max Isacson; Agnes Angerud; Jimmy Caudell
Journal:  J Appl Clin Med Phys       Date:  2022-02-25       Impact factor: 2.243

9.  Dosimetrical and radiobiological approach to manage the dosimetric shift in the transition of dose calculation algorithm in radiation oncology: how to improve high quality treatment and avoid unexpected outcomes?

Authors:  Abdulhamid Chaikh; Jarkko Ojala; Catherine Khamphan; Robin Garcia; Jean Yves Giraud; Juliette Thariat; Jacques Balosso
Journal:  Radiat Oncol       Date:  2018-04-03       Impact factor: 3.481

10.  Clinical implementation of AXB from AAA for breast: Plan quality and subvolume analysis.

Authors:  Alexandra Guebert; Leigh Conroy; Sarah Weppler; Majed Alghamdi; Jessica Conway; Lindsay Harper; Tien Phan; Ivo A Olivotto; Wendy L Smith; Sarah Quirk
Journal:  J Appl Clin Med Phys       Date:  2018-04-25       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.