Dose accuracy improvement on head and neck VMAT treatments by using the Acuros algorithm and accurate FFF beam calibration.

Guadalupe Martin-Martin1, Stefan Walter2, Eduardo Guibelalde3.   

Abstract

BACKGROUND: The purpose of this study was to assess dose accuracy improvement and dosimetric impact of switching from the anisotropic analytical algorithm (AA) to the Acuros XB algorithm (AXB) when performing an accurate beam calibration in head and neck (H&N) FFF-VMAT treatments.
MATERIALS AND METHODS: Twenty H&N cancer patients treated with FFF-VMAT techniques were included. Calculations were performed with the AA and AXB algorithm (dose-to-water - AXBw- and dose-to-medium - AXBm-). An accurate beam calibration was used for AXB calculations. Dose prescription to the tumour (PTV70) and at-risk-nodal region (PTV58.1) were 70 Gy and 58.1 Gy, respectively. A PTV70_bone including bony structures in PTV70 was contoured. Dose-volume parameters were compared between the algorithms. Statistical tests were used to analyze the differences in mean values and the correlation between compliance with the D95 > 95% requirement and occurrence of local recurrence.
RESULTS: AA systematically overestimated the dose compared to AXB algorithm with mean dose differences within 1.3 Gy/2%, except for the PTV70_bone (2.2 Gy/3.2%). Dose differences were significantly higher for AXBm calculations when including accurate beam calibration (maximum dose differences up to 2.8 Gy/4.1% and 4.2 Gy/6.3% for PTV70 and PTV70_bone, respectively). 80% of AA-calculated plans did not meet the D95 > 95% requirement after recalculation with AXBm and accurate beam calibration. The reduction in D95 coverage in the tumour was not clinically relevant.
CONCLUSIONS: Using the AXBm algorithm and carefully reviewing the beam calibration procedure in H&N FFF-VMAT treatments ensures (1) dose accuracy increase by approximately 3%; (2) a consequent dose increase in targets; and (3) a dose reporting mode that is consistent with the trend of current algorithms.
© 2021 Greater Poland Cancer Centre.

Entities:  

Keywords:  Acuros XB (AXB); Anisotropic Analytical Algorithm (AA); FFF-VMAT; head and neck (H&N)

Year:  2021        PMID: 33948305      PMCID: PMC8086705          DOI: 10.5603/RPOR.a2021.0014

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  43 in total

1.  On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

Authors:  Antonella Fogliata; Eugenio Vanetti; Dirk Albers; Carsten Brink; Alessandro Clivio; Tommy Knöös; Giorgia Nicolini; Luca Cozzi
Journal:  Phys Med Biol       Date:  2007-02-08       Impact factor: 3.609

2.  Radiosurgery with unflattened 6-MV photon beams.

Authors:  P F O'Brien; B A Gillies; M Schwartz; C Young; P Davey
Journal:  Med Phys       Date:  1991 May-Jun       Impact factor: 4.071

3.  Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations.

Authors:  K Bush; I M Gagne; S Zavgorodni; W Ansbacher; W Beckham
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Ion recombination and polarity corrections for small-volume ionization chambers in high-dose-rate, flattening-filter-free pulsed photon beams.

Authors:  Megan A Hyun; Jessica R Miller; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2017-02-02       Impact factor: 4.071

5.  Dosimetric impact of Acuros XB dose-to-water and dose-to-medium reporting modes on VMAT planning for head and neck cancer.

Authors:  Carles Muñoz-Montplet; Jordi Marruecos; Maria Buxó; Diego Jurado-Bruggeman; Ingrid Romera-Martínez; Marta Bueno; Joan C Vilanova
Journal:  Phys Med       Date:  2018-11-15       Impact factor: 2.685

6.  Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media.

Authors:  Tao Han; Justin K Mikell; Mohammad Salehpour; Firas Mourtada
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

7.  Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma.

Authors:  Monica W K Kan; Lucullus H T Leung; Ronald W K So; Peter K N Yu
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

8.  Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans.

Authors:  Murugesan Kathirvel; Shanmuga Subramanian; Alessandro Clivio; Gandhi Arun; Antonella Fogliata; Giorgia Nicolini; Vellaiyan Subramani; Shanmugam Thirumalai Swamy; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2013-06-11       Impact factor: 3.481

9.  Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy.

Authors:  Kimiko Hirata; Mitsuhiro Nakamura; Michio Yoshimura; Nobutaka Mukumoto; Manabu Nakata; Hitoshi Ito; Haruo Inokuchi; Yukinori Matsuo; Takashi Mizowaki; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

10.  Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams.

Authors:  Silvia Vargas Castrillón; Francisco Cutanda Henríquez
Journal:  J Med Phys       Date:  2017 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.