Literature DB >> 27469413

Combination Ti/PEEK ALIF cage for anterior lumbar interbody fusion: Early clinical and radiological results.

Ralph Jasper Mobbs1, Kevin Phan2, Yusuf Assem2, Matthew Pelletier3, William R Walsh4.   

Abstract

Anterior lumbar interbody fusion (ALIF) is a common procedure for patients with degenerative pathologies of the lumbar spine. In this study, the clinical and radiological outcomes of a combination titanium/polyetheretherketone (Ti/PEEK) ALIF cages in one, two and three-level surgery were evaluated. Over an 18-month time period, a prospective single surgeon series of 20 implants (15 patients) were included in the study, with minimum 10-months follow-up. From these 15 patients, two were supplemented with posterior percutaneous pedicle screw fixation for additional stability. Radiological follow-up with fine cut CT scan at 9-12months was performed to evaluate early fusion rates, and integration of the Titanium/PEEK cage at the endplate junction. 20 implants were followed for a minimum of 10months, and a mean of 15months. A 95% (19/20 implants) fusion rate with no implant related complications was achieved at the mean 15-month postoperative mark. Patients experienced statistically significant improvement in pain and functional outcomes (SF12 and ODI) compared to their pre-operative status. A single patient with a non-union at L5/S1 (smoker) did not experience any improvement in symptoms. A Ti-PEEK cage, with allograft and BMP-2 to achieve interbody fusion is an effective implant for use in anterior lumbar surgery with high fusion rates, no lucency around the titanium endplates at follow-up, and with promising early results.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  ALIF; Biphasic calcium phosphate; PEEK; Synthetic graft; Titanium

Mesh:

Substances:

Year:  2016        PMID: 27469413     DOI: 10.1016/j.jocn.2016.05.028

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  11 in total

Review 1.  3-dimensional printing for anterior cervical surgery: a review.

Authors:  Wen Jie Choy; William C H Parr; Kevin Phan; William R Walsh; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2018-12

2.  A Prospective, Randomized Study Evaluating Clinical and Radiographic Efficacy of Lumbar Interbody Fusion Performed Using a Truss Technology-Based Interbody Fusion Device With Homologous Bone or Bone Marrow Aspirate.

Authors:  Benjamin Chatterjee; Michael Rauschmann; Christoph Fleege; Mohammad Arabmotlagh; Sven Schmidt; Kimberly Martin; Marcus Rickert
Journal:  Int J Spine Surg       Date:  2020-12-29

3.  Fusion rate and influence of surgery-related factors in lumbar interbody arthrodesis for degenerative spine diseases: a meta-analysis and systematic review.

Authors:  M Formica; D Vallerga; A Zanirato; L Cavagnaro; M Basso; S Divano; L Mosconi; E Quarto; G Siri; L Felli
Journal:  Musculoskelet Surg       Date:  2020-01-01

Review 4.  Evolution of polyetheretherketone (PEEK) and titanium interbody devices for spinal procedures: a comprehensive review of the literature.

Authors:  Nallammai Muthiah; Yagiz Ugur Yolcu; Nima Alan; Nitin Agarwal; David Kojo Hamilton; Alp Ozpinar
Journal:  Eur Spine J       Date:  2022-06-10       Impact factor: 2.721

Review 5.  Is there a variance in complication types associated with ALIF approaches? A systematic review.

Authors:  Aoife Feeley; Iain Feeley; Kevin Clesham; Joseph Butler
Journal:  Acta Neurochir (Wien)       Date:  2021-09-21       Impact factor: 2.816

6.  Intrathecal morphine injection in anterior lumbar and lateral lumbar spine surgery: technical note.

Authors:  Darweesh Al Khawaja
Journal:  J Spine Surg       Date:  2021-06

Review 7.  Interbody Fusions in the Lumbar Spine: A Review.

Authors:  Ravi Verma; Sohrab Virk; Sheeraz Qureshi
Journal:  HSS J       Date:  2020-01-13

8.  Computed tomography color mapping for evaluation of bone ongrowth on the surface of a titanium-coated polyetheretherketone cage in vivo: A pilot study.

Authors:  Takahiro Makino; Takashi Kaito; Yusuke Sakai; Shota Takenaka; Hideki Yoshikawa
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

9.  Additive-manufactured Ti-6Al-4 V/Polyetheretherketone composite porous cage for Interbody fusion: bone growth and biocompatibility evaluation in a porcine model.

Authors:  Pei-I Tsai; Meng-Huang Wu; Yen-Yao Li; Tzu-Hung Lin; Jane S C Tsai; Hsin-I Huang; Hong-Jen Lai; Ming-Hsueh Lee; Chih-Yu Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-02-11       Impact factor: 2.362

10.  Integral fixation titanium/polyetheretherketone cages for cervical arthrodesis: Two-year clinical outcomes and fusion rates using β-tricalcium phosphate or supercritical carbon dioxide treated allograft.

Authors:  Ralph J Mobbs; Tajrian Amin; Daniel Ho; Aidan McEvoy; Vedran Lovric; William R Walsh
Journal:  J Craniovertebr Junction Spine       Date:  2021-12-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.