Literature DB >> 18188374

High-speed phase- and group-delay scanning with a grating-based phase control delay line.

G J Tearney, B E Bouma, J G Fujimoto.   

Abstract

A rapid-scanning optical delay line that employs phase control has several advantages, including high speed, high duty cycle, phase- and group-delay independence, and group-velocity dispersion compensation, over existing optical delay methods for interferometric optical ranging applications. We discuss the grating-based phase-control delay line and its applications to interferometric optical ranging and measurement techniques such as optical coherence domain reflectometry and optical coherence tomography. The system performs optical ranging over an axial range of 3 mm with a scanning rate of 6m/s and a repetition rate of 2 kHz. The device is especially well suited for applications such as optical coherence tomography that require high-speed, repetitive, linear delay line scanning with a high duty cycle.

Year:  1997        PMID: 18188374     DOI: 10.1364/ol.22.001811

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  30 in total

Review 1.  Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy.

Authors:  J G Fujimoto; C Pitris; S A Boppart; M E Brezinski
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

Review 2.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

3.  High-speed optical frequency-domain imaging.

Authors:  S Yun; G Tearney; Johannes de Boer; N Iftimia; B Bouma
Journal:  Opt Express       Date:  2003-11-03       Impact factor: 3.894

4.  Adaptive ranging for optical coherence tomography.

Authors:  N Iftimia; B Bouma; J de Boer; B Park; B Cense; G Tearney
Journal:  Opt Express       Date:  2004-08-23       Impact factor: 3.894

5.  Ultrasound-enhanced optical coherence tomography: improved penetration and resolution.

Authors:  Chuanyong Huang; Bin Liu; Mark E Brezinski
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2008-04       Impact factor: 2.129

6.  Optical Coherence Tomography for Ophthalmology Imaging.

Authors:  Jia Qin; Lin An
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

Review 7.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

8.  Using speckle to measure tissue dispersion in optical coherence tomography.

Authors:  Christos Photiou; Evgenia Bousi; Ioanna Zouvani; Costas Pitris
Journal:  Biomed Opt Express       Date:  2017-04-17       Impact factor: 3.732

9.  Intravascular optical coherence tomography [Invited].

Authors:  Brett E Bouma; Martin Villiger; Kenichiro Otsuka; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

10.  High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe.

Authors:  Aaron D Aguirre; Juergen Sawinski; Shu-Wei Huang; Chao Zhou; Winfried Denk; James G Fujimoto
Journal:  Opt Express       Date:  2010-03-01       Impact factor: 3.894

View more