Literature DB >> 27433200

Reliability of aortic aneurysm screening measurements.

Rachel Weston Smith1, Tony Evans1, Stephen Wolstenhulme2.   

Abstract

The aim of this feasibility study was to assess the impact that image processing of abdominal aortic ultrasound (US) images had on the intra-observer reliability of the diameter measurement. The study compared variability between inner-to-inner (ITI), outer-to-outer (OTO) and outer-to-inner (OTI) wall diameter measurements and their resilience to image processing. Three US images of transverse abdominal aortas were manipulated in 13 different ways using functions from Image J software (National Institutes of Health, Bethesda, MD, USA). Blinded measurements were performed of the aortic diameters from each image; this was repeated for ITI, OTO and OTI. Profiles of each image were produced and sets of rules developed to provide detailed instructions as to where, on the profile, the callipers should be placed to correspond with the actual image. The reliability of the diameter measurements compared to the original diameter measurement was least affected by adjusting the brightness and contrast of the US images (better than ± 1.5 mm). Using the functions 'Sharpen' and 'Find Edges' created the largest difference (up to -5 mm). The ITI measurements had the widest spread of variability, whereas the OTI measurements proved to be the most repeatable and resilient to image processing. This study suggests the precision of the measurements can be kept within satisfactory levels even after image manipulation. It also showed the most reliable measuring guideline was OTI, in contrast to the guideline currently used by the NHS Abdominal Aortic Aneurysm Screening Programme. Further research is needed to transfer the findings into the clinical setting of the National Screening Programme to increase its reliability.

Entities:  

Keywords:  Ultrasound; abdominal aortic aneurysm; diameter; measurement

Year:  2013        PMID: 27433200      PMCID: PMC4760543          DOI: 10.1177/1742271X13513980

Source DB:  PubMed          Journal:  Ultrasound        ISSN: 1742-271X


  12 in total

1.  Comments regarding 'Ultrasound Measurement of Aortic Diameter in a National Screening Programme'.

Authors:  A Wanhainen
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-05-04       Impact factor: 7.069

2.  Ultrasound measurement of aortic diameter in a national screening programme.

Authors:  T C Hartshorne; C N McCollum; J J Earnshaw; J Morris; A Nasim
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-03-24       Impact factor: 7.069

Review 3.  Reproducibility of ultrasound measurement of the abdominal aorta.

Authors:  L Beales; S Wolstenhulme; J A Evans; R West; D J A Scott
Journal:  Br J Surg       Date:  2011-08-22       Impact factor: 6.939

4.  Assessment of ultrasound monitor image display performance.

Authors:  Sally C Moore; Craig R Munnings; David S Brettle; J Anthony Evans
Journal:  Ultrasound Med Biol       Date:  2011-06       Impact factor: 2.998

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Multicentre aneurysm screening study (MASS): cost effectiveness analysis of screening for abdominal aortic aneurysms based on four year results from randomised controlled trial.

Authors: 
Journal:  BMJ       Date:  2002-11-16

Review 7.  Measuring the maximum diameter of native abdominal aortic aneurysms: review and critical analysis.

Authors:  A Long; L Rouet; J S Lindholt; E Allaire
Journal:  Eur J Vasc Endovasc Surg       Date:  2012-02-14       Impact factor: 7.069

8.  Internal or external wall diameter for abdominal aortic aneurysm screening?

Authors:  A Thapar; D Cheal; T Hopkins; S Ward; J Shalhoub; J Shaloub; S W Yusuf
Journal:  Ann R Coll Surg Engl       Date:  2010-06-01       Impact factor: 1.891

9.  Reproducibility of ECG-gated ultrasound diameter assessment of small abdominal aortic aneurysms.

Authors:  K Bredahl; N Eldrup; C Meyer; J E Eiberg; H Sillesen
Journal:  Eur J Vasc Endovasc Surg       Date:  2013-01-17       Impact factor: 7.069

10.  Preventing hospital-acquired urinary tract infection in the United States: a national study.

Authors:  Sanjay Saint; Christine P Kowalski; Samuel R Kaufman; Timothy P Hofer; Carol A Kauffman; Russell N Olmsted; Jane Forman; Jane Banaszak-Holl; Laura Damschroder; Sarah L Krein
Journal:  Clin Infect Dis       Date:  2008-01-15       Impact factor: 9.079

View more