BACKGROUND: To study the accuracy of using the deepest point of the intercondylar notch (DPIN) as a reference point for femoral intramedullary (IM) guiding rod entrance in total knee arthroplasty (TKA) with 3-D reconstruction in Chinese subjects.
METHODS: A total of 50 normal femurs in 25 Chinese subjects (mean age 25.6 ± 2.9 years; range 18-29 years) were chosen from the lower extremities computed tomography digital imaging and communications in medicine (DICOM) database for this study. The DICOM data were imported into Mimics 10.0 software. A cylinder (radius = 4 mm; length = 20 cm) was used to simulate ideal insertion of a IM guiding rod into the femoral canal. DPIN was taken as a reference point for calculating the relative position of the rod's entry point.
RESULTS: The mean rod entry point position in the coronal plane was 2.94 ± 1.12 mm (range 0.79-4.91 mm) medial and 6.01 ± 2.09 mm (range 2.49-9.51 mm) anterior to the DPIN, with no significant difference between sides. All potential angle errors were below 2°.
CONCLUSION: The results of this study show that the DPIN can serve as a reference for surgeons using an IM guide system in TKA.

Entities:  

Mesh:

Year:  2014        PMID: 24519709     DOI: 10.1007/s00402-014-1943-6

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Evaluation of lower limb axial alignment using digital radiography stitched films in pre-operative planning for total knee replacement.

Authors:  Michael J Neil; Jereme B Atupan; Juan Paulo L Panti; Robert A J Massera; Stewart Howard
Journal:  J Orthop       Date:  2016-06-29

2.  Glenoid morphology and the safe zone for protecting the suprascapular nerve during baseplate fixation in reverse shoulder arthroplasty.

Authors:  Yuhui Yang; Jianlin Zuo; Tong Liu; Pu Shao; Haihe Wu; Zhongli Gao; Jianlin Xiao
Journal:  Int Orthop       Date:  2017-09-27       Impact factor: 3.075

3.  Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis.

Authors:  Jian-Jun Li; Dong-Mu Tian; Li Yang; Jing-Yu Zhang; Yong-Cheng Hu
Journal:  J Orthop Surg Res       Date:  2020-12-09       Impact factor: 2.359

4.  Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach.

Authors:  Christoph Stotter; Erich Reiter; Werner Schretter; Philippe Reuter; Stefan Nehrer; Thomas Klestil
Journal:  Jt Dis Relat Surg       Date:  2022-07-06

5.  The position of entry point in total knee arthroplasty is associate with femoral bowing both in coronal and sagittal planes.

Authors:  Xianli Zeng; Yiming Yang; Zhenyu Jia; Jiarong Chen; Hongyuan Shen; Yan Jin; Yao Lu; Pingyue Li
Journal:  Front Surg       Date:  2022-07-18

6.  An innovative three-dimensional method for identifying a proper femoral intramedullary entry point in total knee arthroplasty.

Authors:  Lu-Yao Ma; Hong-Yu Wei; Fu-Yin Wan; Wan-Shou Guo; Jin-Hui Ma
Journal:  Chin Med J (Engl)       Date:  2018-11-05       Impact factor: 2.628

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.