Immediate, Non Submerged Root Analog Zirconia Implant in Single Rooted Tooth Replacement: Case Report with 2 years Follow Up.

Amod Patankar1, Rajesh Kshirsagar1, Swapna Patankar2, Sudhir Pawar1.   

Abstract

This report demonstrates the clinical use of a modified, truly anatomic, root analogue zirconia implant for immediate replacement of a right mandibular first premolar. A 22-year-old female patient with chronic apical periodontitis of the right mandibular first premolar was referred and the tooth was carefully extracted. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 3 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 18 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a single rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy and aids socket prevention. In addition the procedure saves time and cost, has good patient acceptance as there is no need for osteotomy, sinus lift or bone augmentation.

Entities:  

Keywords:  Immediate implant; Root formed implant; Zirconia as material for dental implants; Zirconia implant

Year:  2015        PMID: 27408451      PMCID: PMC4925590          DOI: 10.1007/s12663-015-0786-1

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  8 in total

1.  Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants.

Authors:  Ralf-Joachim Kohal; George Papavasiliou; Phophi Kamposiora; Aris Tripodakis; Jörg Rudolf Strub
Journal:  Int J Prosthodont       Date:  2002 Mar-Apr       Impact factor: 1.681

2.  Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement.

Authors:  W Pirker; A Kocher
Journal:  Int J Oral Maxillofac Surg       Date:  2008-02-12       Impact factor: 2.789

Review 3.  Ceramic abutments and ceramic oral implants. An update.

Authors:  Ralf-J Kohal; Wael Att; Maria Bächle; Frank Butz
Journal:  Periodontol 2000       Date:  2008       Impact factor: 7.589

4.  The dental polymer implant concept.

Authors:  M Hodosh; M Povar; G Shklar
Journal:  J Prosthet Dent       Date:  1969-09       Impact factor: 3.426

5.  Stability of prototype two-piece zirconia and titanium implants after artificial aging: an in vitro pilot study.

Authors:  Ralf-Joachim Kohal; Hans Christian Finke; Gerold Klaus
Journal:  Clin Implant Dent Relat Res       Date:  2008-09-09       Impact factor: 3.932

6.  Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog.

Authors:  D Lundgren; H Rylander; M Andersson; C Johansson; T Albrektsson
Journal:  Clin Oral Implants Res       Date:  1992-09       Impact factor: 5.977

7.  Fracture strength of zirconia implants after artificial aging.

Authors:  Marina Andreiotelli; Ralf-Joachim Kohal
Journal:  Clin Implant Dent Relat Res       Date:  2008-07-24       Impact factor: 3.932

8.  Osseointegration of zirconia implants compared with titanium: an in vivo study.

Authors:  Rita Depprich; Holger Zipprich; Michelle Ommerborn; Christian Naujoks; Hans-Peter Wiesmann; Sirichai Kiattavorncharoen; Hans-Christoph Lauer; Ulrich Meyer; Norbert R Kübler; Jörg Handschel
Journal:  Head Face Med       Date:  2008-12-11       Impact factor: 2.151

  8 in total
  1 in total

Review 1.  Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports.

Authors:  Telma Dantas; Sara Madeira; Michael Gasik; Paula Vaz; Filipe Silva
Journal:  Materials (Basel)       Date:  2021-04-29       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.