Simulation in cardiac catheterization laboratory: Need of the hour to improve the clinical skills.

Shivani Aggarwal1, Erin Choudhury1, Suruchi Ladha1, Poonam Malhotra Kapoor1, Usha Kiran1.   

Abstract

Simulation is an effective teaching tool to decrease the learning curve for novices without compromising patient safety. Simulation helps interventionalist in mentally translating a two dimentional, black and white image into a usable three dimentional model. It also bridges the gap in training diverse team members on new procedures and products. All simulators have collision detection, i.e., virtual contact forces generated from collision which updates haptic output with new calculations.

Entities:  

Mesh:

Year:  2016        PMID: 27397459      PMCID: PMC4971983          DOI: 10.4103/0971-9784.185548

Source DB:  PubMed          Journal:  Ann Card Anaesth        ISSN: 0971-9784


INTRODUCTION

With growing trend toward minimally invasive surgeries, percutaneous endovascular interventional procedures are now preferred alternatives to traditional cardiac surgical procedures. Technological improvement is at the expense of increasing complexity of procedures, with steep learning curves necessitating simultaneous improvements in clinical skills in realistic situations with due regard to patient safety. With increasing public awareness regarding medical errors and patient safety, it is need of the hour to develop new methods for training in medical education. The solution lies in the use of virtual reality simulation. The concept of use of simulation to improve skills and validation of competency is not an alien one. Cadavers and animal models have been used for this purpose since times immemorial. With the advent of high fidelity virtual reality simulators, questions have been raised regarding the currently prevalent traditional certification standards and apprenticeship model. The simulation was first used for laparoscopic surgeries in 1993. Since then, various surgical specialties have adopted this virtual technology for enhancing their surgical skills. The use of simulation in cardiac catheterization laboratory was studied by Bagai et al.[1] who concluded that cardiac catheterization skills can be learned via mentored simulation training and are applicable for actual procedures in the catheterization laboratory. Technical performance was improved in cardiology trainees using simulators before performing on real patients. It was also found that less proficient operators benefit more from simulator training compared to more proficient ones. Simulation is an effective teaching tool to decrease the learning curve for novices without compromising patient safety. Hands-on training using simulators is most effective in enhancing the motor skills and cognitive abilities in the interventional setting for both the physicians as well as the paramedical staff. Trainees can learn and practice proper sequence of catheterization steps.[2] Use of simulation enhances visual and spatial thinking and improves hands-eye coordination. Simulation helps interventionalist in mentally translating a two-dimensional, black and white image into a usable three-dimensional model. It also bridges the gap in training diverse team members on new procedures and products. It makes them better prepared in case complications do occur. Further, feedback in simulation greatly improves performance. Mahmood et al.[3] found that performance did not improve in the absence of feedback on a colonoscopy simulator. Boyle et al.[4] concluded that incorporation of feedback in simulated laparoscopic colectomy training resulted in fewer errors and better learning curves.

BASIC PRINCIPLES OF SIMULATORS

Haptic technology

In simple words, it the technology of adding touch and feeling to computers, i.e., when virtual objects are touched they seem real and tangible. It generates sensory or tactile information using an electromechanical system according to user-guided inputs. Forces applied during manipulation by the trainees on the cannulating device develops a force feedback considered essential for image-assisted navigation and development of tactile dexterity. Both contact and frictional forces can be generated similar to the catheter-initima collisions allowing trainees to have a real like experience. Two types of force feedback are generated, i.e. active (power driven cylinders which generate high torques) and passive (removes energy by damping the motion of objects). Both active and passive feedbacks are incorporated in most modern simulators even though active haptics are usually dormant during patient-specific rehearsals [Figure 1].
Figure 1

Concept of device simulator interaction, allowing trainees to have a real like experience

Concept of device simulator interaction, allowing trainees to have a real like experience All simulators have collision detection, i.e., virtual contact forces generated from collision which updates haptic output with new calculations. Typical guidewire and catheter guide assembly in the endovascular haptic device. Independent guides for each device in a single haptic module permit independent manipulation of each device without influencing the other Haptic-catheter interface.

Vessel segmentation

The vascular lumen data from all tissues is collected via computed tomography (CT)/magnetic resonance (MR) angiography and can be used to create a specific three-dimensional model for relevant vascular structures. These can be customized for specific patients using manual, semi or fully automatic segmentation techniques.

Physiologic feedback

The response generated to pharmacologic or mechanical intervention. These can be displayed, modified, and also recorded as the postoperative report. The responses can be qualitative or quantitative. Quantitative parameters include measurement of vitals such as oxygen saturation, cuff blood pressures, intracardiac pressures via transseptal needles, invasive blood pressures via catheters, heart rate, waveforms for electrocardiogram (ECG) leads and respiratory rate. Apart from these, total procedure time, the amount of contrast used, the number of cine loops, total fluoroscopy, number of roadmaps, interventional maneuvers, devices used, drugs administered, procedural events, imaging actions, and corresponding times for each event can be recorded. Qualitative parameters include changes in vital signs in response to drugs or during catheter insertion, resistances encountered during guiding catheter against vessel wall, beyond the site of lesion or ahead of guidewires, etc. Drugs which can be used include anticoagulants, antiplatelets, inotropes, antiarrhythmics, beta-blockers, vasodilators, vasopressors, antihypertensives, and procoagulants.

Performance feedback

This is provided by every manufacturer. It can be measured both during and after the procedure. It is essential for training, rehearsals, training, and validation of skills. Currently, four endovascular simulator manufacturers provide seven models which are commercially available in North America. These are: Procedicus VIST Lab and VIST-C (Mentice, Gothenburg, Sweden) SimSuite Simantha (Medical Simulation Corporation, Denver, CO, USA) ANGIO Mentor Slim, Dual Slim and Ultimate (Simbionix, Cleveland, OH, USA) CathLab VR (CAE Healthcare, Montreal, Quebec, Canada). Table 1 shows the comparison between various commercially available simulators.
Table 1

Comparison of currently available simulators

Dimentions (cm)WeightPortabilityHaptic modelHaptic unitsActive/passive hapticsDOF/DFFCollision detectionFluid dyanamicsPAC compatibilityPatient specific capability
VIST Lab257×81×196-On casters, portable within buildingXitach CHP6-2Yes--Yes
VIST C117×41×1513.15 kg for device, 5 kg for laptop and monitorCan be checked in on airplaneXitach CHP3-2Yes--Yes
Simantha183×183×76222.25 kg for systemOn casters, portable within buildingProprietary6Both-YesYesNoNo
ANGIO Mentor Slim104×10×134 kg for device, 4 kg for laptop, and 3.2 kg for monitorCan be checked in on airplaneXitach CHP3Both2YesYesYesYes
ANGIO Mentor Dual Slim104×10×138.2 kg for 2 devices, 4 kg for laptop, 3.2 kg for monitorCan be checked in on airplaneXitach CHP6Both2YesYesYesYes
ANGIO Mentor Ultimate127×61×168150 kg for systemOn casters, portable within buildingXitach CHP6Both2YesYesYesYes
CathLab VR---Proprietary-------

DOF: Degrees of freedom, DFF: Degrees of force feedback, PACs: Picture archiving and communication system

Comparison of currently available simulators DOF: Degrees of freedom, DFF: Degrees of force feedback, PACs: Picture archiving and communication system Currently, commercially available endovasculator simulators allow for a variety of angiographic procedures such as insertion and manipulation of guidewires, catheters, and balloons. They allow for manipulation of fluoroscopic images using C-arm as well as quantitative assessments of the amount of contrast used and total fluoroscopic time. These systems also allow for hemodynamic monitoring and management and assessing pharmacological responses to various medications. In addition, the response time in case of an adverse event can also be calculated for assessment and monitoring progress. The common procedures which can be performed on the various simulators are listed in Table 2.
Table 2

Commonly performed procedures available in the simulators

LHCRHCPCIIABPTAVITrans septal ASDPABVPMBVTEVAREVARTEEICEIVUS
CAE+++++
MSC++++++++++
Mentice+++++++++++
Symbionix++++++++++

MSC: Medical simulation company, PCI: Percutaneous coronary intervention, LHC/RHC: Left heart and right heart catherization, TAVI: Transcathetor aortic valve implantation, PABV: Percutaneous aortic ballon valvuloplasty, PMBV: Percutaneous mitral balloon valvuloplasty, TEVAR: Thoracic endovascular aneurysm repair, EVAR: Endovascular aneurysm repair, ICE: Intracardiac echocardiography, IVUS: Intravascular ultrasound, TEE: Transesophageal echocardiography, ASD: Atrial septal defect

Commonly performed procedures available in the simulators MSC: Medical simulation company, PCI: Percutaneous coronary intervention, LHC/RHC: Left heart and right heart catherization, TAVI: Transcathetor aortic valve implantation, PABV: Percutaneous aortic ballon valvuloplasty, PMBV: Percutaneous mitral balloon valvuloplasty, TEVAR: Thoracic endovascular aneurysm repair, EVAR: Endovascular aneurysm repair, ICE: Intracardiac echocardiography, IVUS: Intravascular ultrasound, TEE: Transesophageal echocardiography, ASD: Atrial septal defect

CAE has developed a simulator – CathLab VR™

The cases are grouped into basic and advanced ones on the basis of difficulty levels. These range from simple to complex percutaneous coronary intervention, ostial lesions, use of embolic protection devices, cardiac rhythm management, failed bioprosthetic valve management, transcutaneous aortic valve simulation, etc., [Figure 2]. It also provides a separate fully functional transthoracic and transesophageal echo simulator for use in conjunction with cardiac catheterization simulator.
Figure 2

The Cath VR use for embolic protection devices, cardiac rhythm management, failed bioprosthetic valve management, transcutaneous aortic valve simulation

The Cath VR use for embolic protection devices, cardiac rhythm management, failed bioprosthetic valve management, transcutaneous aortic valve simulation Medical Simulation Corporation (MSC) provides a simulator called Simantha™. It simulates the procedure along with multimodality imaging including live fluoroscopy, static images, ECG, live intravascular ultrasound (IVUS), and static transesophageal echocardiography (TEE). The IVUS and TEE are incorporated in the case presentations. More than 20 drugs can be administered with simultaneous recording of effects on various physiological parameters such as heart rate, respiratory rate, oxygen saturation, cuff blood pressure, level of consciousness, etc. The procedure is carried out in the form of teaching points by rules engine which also allows for a variety of treatment options. The data are recorded during simulation procedures and can be used to create metrics for marketing and training purposes. MSC in association with ABIM has developed specific interventional cardiology cases accredited in ABIM's MOC (Philadelphia, PA 19106-3699) self-assessment program. These include acute myocardial infarction course, basic program, carotid course, diagnostic coronary angiography course, door-to-balloon time simulation workshop, etc. Mentice has developed simulator VIST™ which allows for all types of coronary, neurovascular, peripheral, and structural cases. Fifteen drugs can be used for injection including morphine, heparin, and nitroglycerin. Accordingly, it provides feedback of the real time changes in aortic pressures measured by catheter, any three lead ECG, blood pressure, respiratory rate, heart rate, and oxygen saturation. It allows for both quantitative (total procedure time, the amount of contrast, cine loops, and fluoroscopy time) and qualitative (guiding catheter against the vessel wall, beyond the site of lesion or ahead of guidewires, etc.) monitoring of errors and clinical parameters [Figure 3a–c].
Figure 3

(a-c) Mentice has developed simulator VIST™ which allows for all types of coronary, neurovascular, peripheral and structural cases. Fifteen drugs can be used for injection including morphine, heparin and nitroglycerine

(a-c) Mentice has developed simulator VIST™ which allows for all types of coronary, neurovascular, peripheral and structural cases. Fifteen drugs can be used for injection including morphine, heparin and nitroglycerine VIST™ has single and dual access sites along with radial access. Trainees are free to navigate the vessels and intervene irrespective of the case. Table 3 compares the characteristics of various simulator options provided by Mentice.
Table 3

Comparison of various simulators offered by mentice

Radiation safety trainerVIST CVIST G5VIST Lab with VIST G5
UseFull CathLab staff training of radiation safetyAll types of endovascular trainingAll types of endovascular trainingAll types of endovascular training
Software modules available for purchase318 modules with over 400 cases18 modules with over 400 cases18 modules with over 400 cases
Portability
Force feedback technology
Customisation of cases
Devices usedUp to 6F - only catheter and wire0.014” to 24F (up to 6F on the second tracker)0.014” to 24F (up to 8F on the second tracker)0.014” to 24F (up to 8F on the second tracker)
Dual leg compatiblity
VIST control box included
Fullsize mannequin and 50” monitor
Support for multiple access points
Comparison of various simulators offered by mentice The various modules available are: Acute stroke intervention Aortic valve implantation Below-the-knee intervention Cardiac rhythm management Carotid intervention Coronary angiography Coronary Pro Procedural Training Module Endovascular aortic repair Iliac/superficial femoral artery intervention Left atrial appendage occlusion Neuro-intervention Peripheral angiography Renal denervation Renal intervention Thoracic endovascular aortic repair Transseptal puncture Uterine artery embolization Vascular trauma management. Simbionix provides three simulation platforms. These are ANGIO Mentor Slim, ANGIO Mentor Dual Slim and ANGIO Mentor Ultimate. Although vessel segmentation is semiautomatic, it can be easily accomplished by trained hands even on the day of surgery. More than 100 physiological parameters can be recorded during the procedure and used for tracking the progress. All of them provides simulation for thoracic endovascular aneurysm repair (EVAR) and EVAR [Figure 4].[56] Various complications such as dissections, perforations, aortic puncture or leak, air embolization, vasospasm, etc., can be generated amidst a procedure. For endovascular cases, complications such as difficulty in introducing graft components over an introducer or stiff wire, selection of the correct size of main graft, correct position, the occurrence of endoleak and occlusion of ostia of hypogastric, renal or superior mesenteric arteries can be reproduced.[7] One distinguishing feature is the procedural rehearsal studio, i.e., feeding patient data in simulation cases so that practice can be done on patients actual anatomy. It is available for carotid angiography and intervention as well as endovascular treatment of abdominal aortic aneurysms.
Figure 4

A part of the Simbionix the Angio Ultimate, has more than 100 physiological parameters that can be recorded during a procedure like thoracic endovascular aneurysm repair and endovascular aneurysm repair

A part of the Simbionix the Angio Ultimate, has more than 100 physiological parameters that can be recorded during a procedure like thoracic endovascular aneurysm repair and endovascular aneurysm repair Endovascular evaluator (EVE) is a model reconstructing human vascular lumen using CT/MR imaging data. It is composed of 16 modules which can be customized according to the requirements. It is light weight (dry weight 3.8 kg) enabling easy transportation. These are made of silicone having elasticity coefficient similar to arteries (2 MPa). The friction coefficient of the arteries is 0.038 and that of the simulator is 0.042 which can also be adjusted by the user by altering the concentration of circulating surfactant. It thus simulates the elasticity and friction of the human vasculature and allows real time experience of catheter manipulation. These are also X-ray compatible further enhancing the simulation quality [Figure 5]. The procedures supported by EVE include cerebral artery embolism with coil or balloon, carotid artery stenting, percutaneous transluminal coronary angioplasty, aortic stent grafts, catheter and guidewire insertion, (percutaneous transluminal recanalization, transcatheter hepatic artery embolization, and percutaneous transluminal angioplasty with balloon or stents [Figure 6].
Figure 5

The Angio Slim as an endovascular evaluator is compatible with X-rays and thus enhances the simulation quality

Figure 6

The enhanced simulation system

The Angio Slim as an endovascular evaluator is compatible with X-rays and thus enhances the simulation quality The enhanced simulation system Simulation can thus be considered as an effective tool for training, education, certification, and acquisition of new technological skills for both novices and experts in medical and paramedical fields. It is even more important for cardiac catheterization laboratory which is a dynamic module requiring trained interventional nurses and technicians in addition to physician's skills and experience for the successful patient outcome. The Food and Drug Administration also advocates the use of virtual reality simulators for approving new devices. Considering that the main aim of improvements in medical technology has been to improve patient comfort and safety, simulation can play a key role in fulfilling this goal.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  7 in total

1.  The learning curve for a colonoscopy simulator in the absence of any feedback: no feedback, no learning.

Authors:  T Mahmood; A Darzi
Journal:  Surg Endosc       Date:  2004-06-23       Impact factor: 4.584

2.  Training with simulation improves residents' endovascular procedure skills.

Authors:  David L Dawson; Jennifer Meyer; Eugene S Lee; William C Pevec
Journal:  J Vasc Surg       Date:  2007-01       Impact factor: 4.268

Review 3.  The current state of medical simulation in interventional cardiology: a clinical document from the Society for Cardiovascular Angiography and Intervention's (SCAI) Simulation Committee.

Authors:  Sandy M Green; Andrew J Klein; Samir Pancholy; Sunil V Rao; Daniel Steinberg; Rebecca Lipner; Jeffery Marshall; John C Messenger
Journal:  Catheter Cardiovasc Interv       Date:  2013-10-17       Impact factor: 2.692

4.  Simulation-based endovascular skills assessment: the future of credentialing?

Authors:  Maureen M Tedesco; Jimmy J Pak; E John Harris; Thomas M Krummel; Ronald L Dalman; Jason T Lee
Journal:  J Vasc Surg       Date:  2008-04-18       Impact factor: 4.268

5.  Mentored simulation training improves procedural skills in cardiac catheterization: a randomized, controlled pilot study.

Authors:  Akshay Bagai; Sean O'Brien; Hatim Al Lawati; Prateek Goyal; Warren Ball; Teodor Grantcharov; Neil Fam
Journal:  Circ Cardiovasc Interv       Date:  2012-10-09       Impact factor: 6.546

6.  Principal considerations for the contemporary high-fidelity endovascular simulator design used in training and evaluation.

Authors:  Benjamin A Eslahpazir; Jerry Goldstone; Matthew T Allemang; John C Wang; Vikram S Kashyap
Journal:  J Vasc Surg       Date:  2014-01-11       Impact factor: 4.268

7.  Optimising surgical training: use of feedback to reduce errors during a simulated surgical procedure.

Authors:  Emily Boyle; Musallam Al-Akash; Anthony G Gallagher; Oscar Traynor; Arnold D K Hill; Paul C Neary
Journal:  Postgrad Med J       Date:  2011-06-03       Impact factor: 2.401

  7 in total
  5 in total

1.  Simulation in cardiac critical care: New times and new solutions.

Authors:  Poonam Malhotra Kapoor; Kalpana Irpachi
Journal:  Ann Card Anaesth       Date:  2016 Jul-Sep

Review 2.  Review of the effect of 3D medical printing and virtual reality on urology training with ‘MedTRain3DModsim’ Erasmus + European Union Project

Authors:  İlkan Tatar; Emre Huri; İlker Selçuk; Young Lee Moon; Alberto Paoluzzi; Andreas Skolarikos
Journal:  Turk J Med Sci       Date:  2019-10-24       Impact factor: 0.973

3.  CT-Derived 3D Printing for Coronary Artery Cannulation Simulator Design Manufacturing.

Authors:  Helvina Vika Etami; Rochmi Isnaini Rismawanti; Vita Arfiana Nur Hanifah; Herianto Herianto; Yarabisa Yanuar; Djoko Kuswanto; Dyah Wulan Anggrahini; Putrika Prastuti Ratna Gharini
Journal:  Bioengineering (Basel)       Date:  2022-07-25

4.  Recent Developments and Current Status of Transcatheter Aortic Valve Replacement Practice in Latin America - the WRITTEN LATAM Study.

Authors:  Fernando Luiz de Melo Bernardi; Henrique Barbosa Ribeiro; Luis Nombela-Franco; Enrico Cerrato; Gabriel Maluenda; Tamim Nazif; Pedro Alves Lemos; Matias Sztejfman; Pablo Lamelas; Dario Echeverri; Marcelo Antonio Cartaxo Queiroga Lopes; Fábio Sândoli de Brito; Alexandre A Abizaid; José A Mangione; Helene Eltchaninoff; Lars Søndergaard; Josep Rodes-Cabau
Journal:  Arq Bras Cardiol       Date:  2022-06-10       Impact factor: 2.667

5.  VCSim3: a VR simulator for cardiovascular interventions.

Authors:  Przemyslaw Korzeniowski; Ruth J White; Fernando Bello
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-10-27       Impact factor: 2.924

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.