Literature DB >> 24418640

Principal considerations for the contemporary high-fidelity endovascular simulator design used in training and evaluation.

Benjamin A Eslahpazir1, Jerry Goldstone2, Matthew T Allemang2, John C Wang2, Vikram S Kashyap3.   

Abstract

BACKGROUND: The simulation and rehearsal of virtual endovascular procedures are anticipated to improve the outcomes of actual procedures. Contemporary, high-fidelity simulation is based on feedback systems that combine concepts of mechanical, electrical, computer, and control systems engineering to reproduce an interactive endovascular case. These sophisticated devices also include psychometric instruments for objective surgical skill assessment. The goal of this report is to identify the design characteristics of commercially available simulators for endovascular procedures and to provide a cross-section comparison across all devices to aid in the simulator selection process.
METHODS: Data were obtained (1) by a standard questionnaire issued to four simulator companies prompting for relevant design details of each model for the expressed purpose of publication, (2) from each manufacturer's respective website including appended sales brochures and specification sheets, and (3) by an evaluation of peer-reviewed literature. Focus topics include haptic technology, vessel segmentation, physiologic feedback, performance feedback, and physical logistics (ie, weight, dimensions, and portability). All data sources were surveyed between January 1, 2012, and June 30, 2013.
RESULTS: All of the commercially available, high-fidelity endovascular simulators use interactive virtual environments with preprogrammed physics and physiology models for accurate reproduction of surgical reality. The principal differences between devices are the number of access sites and haptic devices, the ability to reconstruct patient-specific anatomy for preprocedural rehearsal, and the available peripheral training modalities. Hardware and software options can also vary within the same device in comparing patient-specific with generic cases.
CONCLUSIONS: Despite our limited knowledge about the potential of high-fidelity simulation within the endovascular world, today's currently available simulators successfully provide high-fidelity reproductions of the endovascular environment. We have found that all of the commercially available devices incorporate the necessary features for a high-fidelity experience: (1) haptic technology, (2) vessel reconstruction, (3) physiology feedback, and (4) performance feedback. Significant variations in design do exist and may influence differences in skill development, evaluation, or cost. However, further validation of these differences is still needed and would benefit program directors interested in expanding these platforms for vascular training and certification as this technology matures.
Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24418640     DOI: 10.1016/j.jvs.2013.11.074

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

1.  Design and performance evaluation of a master controller for endovascular catheterization.

Authors:  Jin Guo; Shuxiang Guo; Takashi Tamiya; Hideyuki Hirata; Hidenori Ishihara
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-06-13       Impact factor: 2.924

2.  New Generation of Three-Dimensional Tools to Learn Anatomy.

Authors:  Roberto D Tabernero Rico; Juan A Juanes Méndez; Alberto Prats Galino
Journal:  J Med Syst       Date:  2017-04-12       Impact factor: 4.460

Review 3.  Simulation in cardiac catheterization laboratory: Need of the hour to improve the clinical skills.

Authors:  Shivani Aggarwal; Erin Choudhury; Suruchi Ladha; Poonam Malhotra Kapoor; Usha Kiran
Journal:  Ann Card Anaesth       Date:  2016 Jul-Sep

Review 4.  Robotics in neurointerventional surgery: a systematic review of the literature.

Authors:  William Crinnion; Ben Jackson; Avnish Sood; Jeremy Lynch; Christos Bergeles; Hongbin Liu; Kawal Rhode; Vitor Mendes Pereira; Thomas C Booth
Journal:  J Neurointerv Surg       Date:  2021-11-19       Impact factor: 8.572

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.