Literature DB >> 27378497

Thrombus-mimicking artifacts in two-point Dixon MRI: Prevalence, appearance, and severity.

Tilman Schubert1,2, Peter Bannas1,3, Sonja Kinner1,4, Samir Sharma5, James H Holmes1,5, Mahdi Salmani Rahimi5, Frank R Korosec1,5, Scott B Reeder1,5,6,7.   

Abstract

PURPOSE: To evaluate the incidence and severity of potentially thrombus mimicking, flow-induced misallocation artifacts in a clinical setting. Two-point "Dixon" fat-water separation methods, with bipolar readout gradients, may suffer from flow-induced fat-water misallocation artifacts. If these artifacts occur within blood vessels, they may mimic thrombus.
MATERIALS AND METHODS: Two-point Dixon coronal and axial images acquired in 102 consecutive patients were retrospectively evaluated for the presence of flow-induced artifacts in arteries and veins. Artifacts were graded on a 3-point scale (none, mild, severe) by two independent readers. Interreader agreement was evaluated with kappa statistics.
RESULTS: Reader 1 reported 63 artifacts in 46 (45%) of the cases (severe in 19 cases, 18.6%). Reader 2 reported 51 artifacts in 43 (42.2%) of the cases (severe in 18 cases, 17.6%). Misallocation of fat and water was apparent in all datasets with severe artifacts, whereas variable signal intensity changes in water and fat images were observed in mild artifacts. Interreader agreement was good for artifacts appearing in coronal images (κ = 0.7) and fair for artifact appearance in axial images (κ = 0.24).
CONCLUSION: Our study shows a high incidence of flow-induced mild and severe artifacts in a two-point Dixon method with bipolar readout gradients. This artifact should not be misinterpreted as intravascular thrombus. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:229-236.
© 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRI; chemical shift-based; fat-water separation; two-point Dixon

Mesh:

Year:  2016        PMID: 27378497      PMCID: PMC5537627          DOI: 10.1002/jmri.25357

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Feasibility of gadofosveset-enhanced steady-state magnetic resonance angiography of the peripheral vessels at 3 Tesla with Dixon fat saturation.

Authors:  Henrik J Michaely; Ulrike I Attenberger; Olaf Dietrich; Peter Schmitt; Kambiz Nael; Harald Kramer; Maximilian F Reiser; Stefan O Schoenberg; Michael Walz
Journal:  Invest Radiol       Date:  2008-09       Impact factor: 6.016

Review 3.  Fat and water magnetic resonance imaging.

Authors:  Thorsten A Bley; Oliver Wieben; Christopher J François; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

4.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

5.  Subtractionless first-pass single contrast medium dose peripheral MR angiography using two-point Dixon fat suppression.

Authors:  Tim Leiner; Jesse Habets; Bastiaan Versluis; Liesbeth Geerts; Eveline Alberts; Niels Blanken; Jeroen Hendrikse; Evert-Jan Vonken; Holger Eggers
Journal:  Eur Radiol       Date:  2013-04-17       Impact factor: 5.315

Review 6.  Chemical shift encoding-based water-fat separation methods.

Authors:  Holger Eggers; Peter Börnert
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

7.  Pulmonary MRA: differentiation of pulmonary embolism from truncation artefact.

Authors:  Peter Bannas; Mark L Schiebler; Utaroh Motosugi; Christopher J François; Scott B Reeder; Scott K Nagle
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

8.  Accuracy of liver fat quantification at MR imaging: comparison of out-of-phase gradient-echo and fat-saturated fast spin-echo techniques--initial experience.

Authors:  Aliya Qayyum; Jeffrey S Goh; Sanjay Kakar; Benjamin M Yeh; Raphael B Merriman; Fergus V Coakley
Journal:  Radiology       Date:  2005-11       Impact factor: 11.105

9.  Improving chemical shift encoded water-fat separation using object-based information of the magnetic field inhomogeneity.

Authors:  Samir D Sharma; Nathan S Artz; Diego Hernando; Debra E Horng; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-02-28       Impact factor: 4.668

10.  Flow-induced signal misallocation artifacts in two-point fat-water chemical shift MRI.

Authors:  Mahdi Salmani Rahimi; James H Holmes; Kang Wang; Scott B Reeder; Frank R Korosec
Journal:  Magn Reson Med       Date:  2014-06-09       Impact factor: 4.668

View more
  2 in total

1.  Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression.

Authors:  Eric G Stinson; Joshua D Trzasko; Norbert G Campeau; James F Glockner; John Huston; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2018-02-27       Impact factor: 4.668

2.  Simultaneous Multiple Resonance Frequency imaging (SMURF): Fat-water imaging using multi-band principles.

Authors:  Beata Bachrata; Bernhard Strasser; Wolfgang Bogner; Albrecht Ingo Schmid; Radim Korinek; Martin Krššák; Siegfried Trattnig; Simon Daniel Robinson
Journal:  Magn Reson Med       Date:  2020-09-27       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.