Literature DB >> 27363962

Outcomes of implantable collamer lens V4 and V4c for correction of high myopia - a case series.

Smita Karandikar, Vipul Bhandari, Jagdeesh Reddy.   

Abstract

OBJECTIVE: To evaluate the visual outcomes and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with centraflow technology) for correction of myopia.
MATERIALS AND METHODS: A prospective, consecutive, comparative interventional case series of V4b and V4c ICL implantation done for correction of high myopia (>-6 diopter D) in patients unsuitable for laser vision correction. The outcome measures that were evaluated included preoperative and postoperative uncorrected distant visual acuity (UDVA), best spectacle corrected distant visual acuity (CDVA), endothelial cell count (ECC), presence of lens opacification, intraocular pressure (IOP) and ICL vaulting. A follow-up of upto 1 year was done. A questionnaire was given at the end of follow-up period.
RESULTS: A total of 30 eyes (24.56±4.8 years) underwent V4b ICL implantation (10 non-toric, 20 toric ICL-TICL) with intraoperative peripheral iridectomy (PI) and 34 eyes (26.13±3.8 years) had implantation of V4c ICL with centraflow (12 non-toric, 22 TICL). The mean preoperative manifest spherical equivalent (MSE) was 8.98±2.8 D and 9.24±2.4 D in the V4b and V4c groups respectively which reduced to postoperative values of -0.28±1.3 D and -0.19±1.18 D respectively. The mean preoperative astigmatism was -1.8±1.2 diopter cylinder (Dcyl) and -1.9±1.6 Dcyl which respectively reduced to -0.8±0.8 Dcyl and -0.9±0.3 Dcyl. At the end of 1 year follow up, mean ECC loss was 7.6% and 7.1%, mean vault was 583.12±231.12 μ and 602±241.24μ respectively in the V4b and V4c groups. Anterior subcapsular opacities were present in 6.66% and 2.94% of eyes with V4b and V4c groups respectively. Two eyes from both V4b (10%) and V4c (8.33%) had rotation of more than 30 degrees and required re-rotation surgery done successfully. Two eyes (6.66%) with V4b ICL implantation had high postoperative IOP (>35 mm Hg) and required Nd:Yag laser iridotomy later done with successful control of IOP. The safety indices were 1.12 and 1.15 and efficacy indices were 1.5 and 1.6 in the V4b and V4c groups respectively at the end of 1 year. The most common visual complaint was glare and haloes in 24% and 27% in the two groups respectively. However, they were not annoying enough to cause visual disability.
CONCLUSIONS: Both V4b and V4c Visian ICL implantations are comparable in terms of visual outcome and safety profile for correction of high myopia. However, V4c ICL offers these advantages without the requirement of an additional PI. © NEPjOPH.

Entities:  

Year:  2015        PMID: 27363962     DOI: 10.3126/nepjoph.v7i2.14967

Source DB:  PubMed          Journal:  Nepal J Ophthalmol        ISSN: 2072-6805


  6 in total

1.  [Intraocular pressure after implantation of an ICL with aquaport : Development of intraocular pressure after implantation of an ICL (model V4c) with aquaport without iridotomy].

Authors:  B Repplinger; T Kohnen
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

2.  Posterior-Chamber Phakic Intraocular Lens Implantation in Patients over 40 Years of Age.

Authors:  Pedro Tañá-Rivero; Francisco Pastor-Pascual; Marceliano Crespo; José L Rodríguez-Prats; José J Muñoz-Tomás; Robert Montés-Micó
Journal:  J Ophthalmol       Date:  2020-06-29       Impact factor: 1.909

3.  Visual Outcomes, Footplate Position and Vault Achieved with the Visian Implantable Collamer Lens for Myopic Astigmatism.

Authors:  Dan Z Reinstein; Ryan S Vida; Timothy J Archer
Journal:  Clin Ophthalmol       Date:  2021-11-20

4.  Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes.

Authors:  Ruoyan Wei; Meiyan Li; Aruma Aruma; Michael C Knorz; Dong Yang; Yongfu Yu; Xiaoying Wang; Joanne Choi; Peijun Yao; Xingtao Zhou
Journal:  J Cataract Refract Surg       Date:  2022-03-30       Impact factor: 3.528

5.  Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia.

Authors:  Zhipeng Yan; Huamao Miao; Feng Zhao; Xiaoying Wang; Xun Chen; Meiyan Li; Xingtao Zhou
Journal:  J Ophthalmol       Date:  2018-07-03       Impact factor: 1.909

6.  Multicenter clinical outcomes of hole implantable collamer lens implantation in middle-aged patients.

Authors:  Akihito Igarashi; Kazutaka Kamiya; Kazuo Ichikawa; Yoshihiro Kitazawa; Takashi Kojima; Tomoaki Nakamura; Kimiya Shimizu
Journal:  Sci Rep       Date:  2022-03-10       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.