Abstract

SEEG is a method and technique which is used for accurate, invasive recording of seizure activity via three dimensional recordings. In epilepsy patients who are deemed appropriate candidates for invasive recordings, the decision to monitor is made between the subdural grids versus SEEG. Invasive neuromonitoring for epilepsy is pursued in patients with complex, medically refractory epilepsy. The goal of invasive monitoring is to offer resective surgery with the hope of allowing seizure freedom. SEEG's advantages include access to deep cortical structures, an ability to localize the epileptogenic zone (EZ) when subdural grids have failed to do so, and in patients with non-lesional extra-temporal epilepsies. In this manuscript, we present a succinct historical overview of the SEEG and report on our experience with frameless stereotaxy under robotic. An imperative step of SEEG insertion is planning the electrode trajectories. In order to most effectively record ictal activity via SEEG trajectories should be planned based upon a hypothesis of where the seizure activity originates the presumed epileptogenic zone (EZ). The EZ hypothesis is based on a standardized preoperative workup including video-EEG monitoring, MRI (magnetic resonance imaging), PET (positron emission tomography), ictal SPECT (Single-photon emission computed tomography), and neuropsychological assessment. Using a suspected EZ, SEEG electrodes can be placed minimally invasively yet maintain accuracy and precision. Clinical results showed the ability to localize the EZ in 78% of difficult to localize epileptic patients.(1).

Entities:  

Mesh:

Year:  2016        PMID: 27341141      PMCID: PMC4927789          DOI: 10.3791/53206

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  15 in total

1.  Stereotactic placement of depth electrodes in medically intractable epilepsy.

Authors:  Jorge Gonzalez-Martinez; Jeffrey Mullin; Sumeet Vadera; Juan Bulacio; Gwyneth Hughes; Stephen Jones; Rei Enatsu; Imad Najm
Journal:  J Neurosurg       Date:  2014-01-03       Impact factor: 5.115

2.  Multimodality MRI in mesial temporal sclerosis: relative sensitivity and specificity.

Authors:  R I Kuzniecky; E Bilir; F Gilliam; E Faught; C Palmer; R Morawetz; G Jackson
Journal:  Neurology       Date:  1997-09       Impact factor: 9.910

3.  Robot-assisted stereotactic laser ablation in medically intractable epilepsy: operative technique.

Authors:  Jorge Gonzalez-Martinez; Sumeet Vadera; Jeffrey Mullin; Rei Enatsu; Andreas V Alexopoulos; Ravish Patwardhan; William Bingaman; Imad Najm
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

4.  [Epilepsy after 60 years of age. Experience in a functional neurosurgical department].

Authors:  J Bancaud
Journal:  Sem Hop       Date:  1970-11-28

5.  Stereo-electroencephalography methodology: advantages and limits.

Authors:  C Munari; D Hoffmann; S Francione; P Kahane; L Tassi; G Lo Russo; A L Benabid
Journal:  Acta Neurol Scand Suppl       Date:  1994

6.  Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures.

Authors:  Francesco Cardinale; Massimo Cossu; Laura Castana; Giuseppe Casaceli; Marco Paolo Schiariti; Anna Miserocchi; Dalila Fuschillo; Alessio Moscato; Chiara Caborni; Gabriele Arnulfo; Giorgio Lo Russo
Journal:  Neurosurgery       Date:  2013-03       Impact factor: 4.654

7.  Stereoelectroencephalography in the "difficult to localize" refractory focal epilepsy: early experience from a North American epilepsy center.

Authors:  Jorge Gonzalez-Martinez; Juan Bulacio; Andreas Alexopoulos; Lara Jehi; William Bingaman; Imad Najm
Journal:  Epilepsia       Date:  2012-09-27       Impact factor: 5.864

8.  Neurophysiological monitoring for epilepsy surgery: the Talairach SEEG method. StereoElectroEncephaloGraphy. Indications, results, complications and therapeutic applications in a series of 100 consecutive cases.

Authors:  M Guenot; J Isnard; P Ryvlin; C Fischer; K Ostrowsky; F Mauguiere; M Sindou
Journal:  Stereotact Funct Neurosurg       Date:  2001       Impact factor: 1.875

9.  Efficacy of and morbidity associated with stereoelectroencephalography using computerized tomography--or magnetic resonance imaging-guided electrode implantation.

Authors:  Antonio Nogueira De Almeida; André Olivier; Felipe Quesney; François Dubeau; Ghislaine Savard; Frederick Andermann
Journal:  J Neurosurg       Date:  2006-04       Impact factor: 5.115

10.  Stereoelectroencephalography following subdural grid placement for difficult to localize epilepsy.

Authors:  Sumeet Vadera; Jeffrey Mullin; Juan Bulacio; Imad Najm; William Bingaman; Jorge Gonzalez-Martinez
Journal:  Neurosurgery       Date:  2013-05       Impact factor: 4.654

View more
  2 in total

1.  Improving patient safety during introduction of novel medical devices through cumulative summation analysis.

Authors:  Vejay N Vakharia; Roman Rodionov; Andrew W McEvoy; Anna Miserocchi; Rachel Sparks; Aidan G O'Keeffe; Sebastien Ourselin; John S Duncan
Journal:  J Neurosurg       Date:  2018-02-16       Impact factor: 5.115

2.  Neurosurgical robot-assistant stereoelectroencephalography system: Operability and accuracy.

Authors:  Di Zhang; Xuehua Cui; Jie Zheng; Shunyao Zhang; Meng Wang; Wenpeng Lu; Linxia Sang; Wenling Li
Journal:  Brain Behav       Date:  2021-09-14       Impact factor: 2.708

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.