Literature DB >> 24405074

Stereotactic placement of depth electrodes in medically intractable epilepsy.

Jorge Gonzalez-Martinez1, Jeffrey Mullin, Sumeet Vadera, Juan Bulacio, Gwyneth Hughes, Stephen Jones, Rei Enatsu, Imad Najm.   

Abstract

OBJECT: Despite its long-reported successful record, with almost 60 years of clinical use, the technical complexity regarding the placement of stereoelectroencephalography (SEEG) depth electrodes may have contributed to the limited widespread application of the technique in centers outside Europe. The authors report on a simplified and novel SEEG surgical technique in the extraoperative mapping of refractory focal epilepsy.
METHODS: The proposed technique was applied in patients with medically refractory focal epilepsy. Data regarding general demographic information, method of electrode implantation, time of implantation, number of implanted electrodes, seizure outcome after SEEG-guided resections, and complications were prospectively collected.
RESULTS: From March 2009 to April 2012, 122 patients underwent SEEG depth electrode implantation at the Cleveland Clinic Epilepsy Center in which the authors' technique was used. There were 65 male and 57 female patients whose mean age was 33 years (range 5-68 years). The group included 21 pediatric patients (younger than 18 years). Planning and implantations were performed in a single stage. The time for planning was, on average, 33 minutes (range 20-47 minutes), and the time for implantation was, on average, 107 minutes (range 47-150 minutes). Complications related to the SEEG technique were observed in 3 patients. The calculated risk of complications per electrode was 0.18%. The seizure-free rate after SEEG-guided resections was 62% in a mean follow-up period of 12 months.
CONCLUSIONS: The authors report on a safe, simplified, and less time-consuming method of SEEG depth electrode implantation, using standard and widely available surgical tools, making the technique a reasonable option for extraoperative monitoring of patients with medically intractable epilepsy in centers lacking the Talairach stereotactic armamentarium.

Entities:  

Mesh:

Year:  2014        PMID: 24405074     DOI: 10.3171/2013.11.JNS13635

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  36 in total

1.  Investigating the function of deep cortical and subcortical structures using stereotactic electroencephalography: lessons from the anterior cingulate cortex.

Authors:  Robert A McGovern; Tarini Ratneswaren; Elliot H Smith; Jennifer F Russo; Amy C Jongeling; Lisa M Bateman; Catherine A Schevon; Neil A Feldstein; Guy M McKhann; Sameer Sheth
Journal:  J Vis Exp       Date:  2015-04-15       Impact factor: 1.355

2.  Combination of CT angiography and MRI in surgical planning of deep brain stimulation.

Authors:  Marie T Krüger; Volker A Coenen; Carolin Jenkner; Horst Urbach; Karl Egger; Peter C Reinacher
Journal:  Neuroradiology       Date:  2018-08-22       Impact factor: 2.804

3.  "Laser and the Tuber": thermal dynamic and volumetric factors influencing seizure outcomes in pediatric subjects with tuberous sclerosis undergoing stereoencephalography-directed laser ablation of tubers.

Authors:  Michael A Stellon; Kelsey Cobourn; Matthew T Whitehead; Nancy Elling; William McClintock; Chima O Oluigbo
Journal:  Childs Nerv Syst       Date:  2019-06-17       Impact factor: 1.475

Review 4.  The usefulness of stereo-electroencephalography (SEEG) in the surgical management of focal epilepsy associated with "hidden" temporal pole encephalocele: a case report and literature review.

Authors:  João Paulo Sant Ana Santos de Souza; Jeff Mullin; Connor Wathen; Juan Bulacio; Patrick Chauvel; Lara Jehi; Jorge Gonzalez-Martinez
Journal:  Neurosurg Rev       Date:  2017-10-16       Impact factor: 3.042

5.  Safety and Utility of Hybrid Depth Electrodes for Seizure Localization and Single-Unit Neuronal Recording.

Authors:  April A Carlson; Ueli Rutishauser; Adam N Mamelak
Journal:  Stereotact Funct Neurosurg       Date:  2018-10-16       Impact factor: 1.875

6.  Outcome after individualized stereoelectroencephalography (sEEG) implantation and navigated resection in patients with lesional and non-lesional focal epilepsy.

Authors:  Jun Thorsteinsdottir; Christian Vollmar; Jörg-Christian Tonn; Friedrich-Wilhelm Kreth; Soheyl Noachtar; Aurelia Peraud
Journal:  J Neurol       Date:  2019-01-30       Impact factor: 4.849

7.  Stereo-Electro-Encephalo-Graphy (SEEG) With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note.

Authors:  Jeffrey P Mullin; Saksith Smithason; Jorge Gonzalez-Martinez
Journal:  J Vis Exp       Date:  2016-06-13       Impact factor: 1.355

Review 8.  Emerging surgical therapies in the treatment of pediatric epilepsy.

Authors:  Michael Karsy; Jian Guan; Katrina Ducis; Robert J Bollo
Journal:  Transl Pediatr       Date:  2016-04

9.  Safety profile of intracranial electrode implantation for video-EEG recordings in drug-resistant focal epilepsy.

Authors:  Bertrand Mathon; Stéphane Clemenceau; Dominique Hasboun; Marie-Odile Habert; Hayat Belaid; Vi-Huong Nguyen-Michel; Virginie Lambrecq; Vincent Navarro; Sophie Dupont; Michel Baulac; Philippe Cornu; Claude Adam
Journal:  J Neurol       Date:  2015-09-26       Impact factor: 4.849

10.  Stereotactic EEG via multiple single-path omnidirectional trajectories within a single platform: institutional experience with a novel technique.

Authors:  Michael C Dewan; Robert Shults; Andrew T Hale; Vishad Sukul; Dario J Englot; Peter Konrad; Hong Yu; Joseph S Neimat; William Rodriguez; Benoit M Dawant; Srivatsan Pallavaram; Robert P Naftel
Journal:  J Neurosurg       Date:  2018-11-01       Impact factor: 5.115

View more