Literature DB >> 27307671

PowerScope a Class II corrector - A case report.

Joby Paulose1, Palathottungal Joseph Antony1, Brijesh Sureshkumar1, Susha Mariam George1, Manu Mundackal Mathew1, Joseph Sebastian1.   

Abstract

Managing mild to moderate Class II malocclusion is a one of the common and major challenges to orthodontists. Class II discrepancies with mandibular deficiency during active growth are usually treated by myofunctional appliances. Fixed functional appliances evolved due to the noncompliance with conventional myofunctional appliances. This case report illustrates the efficiency of PowerScope in correction of skeletal Class II with mandibular deficiency in a patient aged 13 years who has reported to the department with a chief complaint of forwardly placed upper front teeth. This case with functional jaw retrusion was treated initially with MBT 0.022" prescription followed by PowerScope. Pre-, mid- and post-treatment cephalograms were obtained, and cephalometric analysis was performed. Stable and successful results were obtained with a substantial improvement in facial profile, skeletal jaw relationship, and overall esthetic appearance of the patient. A significant forward displacement of the mandible was the principal element for successful correction of Class II malocclusion. PowerScope provides the best results for Class II management, thus enables us to treat such cases by a nonextraction approach rather than contemplating extractions.

Entities:  

Keywords:  Class II malocclusion; PowerScope; fixed functional appliance; nonextraction

Year:  2016        PMID: 27307671      PMCID: PMC4906867          DOI: 10.4103/0976-237X.183044

Source DB:  PubMed          Journal:  Contemp Clin Dent        ISSN: 0976-2361


Introduction

Class II malocclusion presents a major and common challenge to orthodontists.[1] It may be a dental Class II or may have an unseen skeletal component.[2] Skeletal Class II jaw relation may be due to a prognathic maxilla, retrognathic mandible, or a combination of both. Mandibular retrognathism may be due to small mandible, posterior placement of condyle in glenoid fossa or may be due to functional retrusion of mandible. Management of Class II malocclusion depends entirely on the severity of the problem and the age at which the treatment is carried out. According to McNamara,[3] the most common characteristic of Class II malocclusion is mandibular retrusion, rather than maxillary prognathism. A functional appliance treatment for mandibular advancement is often advocated in Class II malocclusion due to mandibular retrusion.[4567] In patients, who have not yet crossed the adolescent growth spurt, removable functional appliance such as activator, bionator, Twin block, and Frankel may be used.[8] If the patient reports after the pubertal growth spurt or during the late stages of puberty fixed functional appliances such as fixed twin block, Jasper jumper, Herbst, Universal bite jumper, Ritto appliance, Eureka Spring, and Forsus fatigue resistant device (FRD) would be a better choice considering the patient compliance. PowerScope is the latest innovation in Class II correction which is a direct derivative of the Herbst Type II appliance. Dr. Andy Hayes worked in conjunction with American Orthodontics to develop PowerScope [Figure 1].[9] This appliance addresses critical needs of the orthodontist including the patient comfort and acceptance, extensive range of motion, simple installation, and much more. No studies on treatment outcomes of comprehensive fixed appliance treatment combined with the PowerScope in Class II patients have been reported so far. This paper presents a nonextraction approach in the treatment of skeletal Class II using the PowerScope.
Figure 1

PowerScope appliance armamentarium consisting of telescopic push rods (right and left), hexagonal screwdriver, and crimpable shims

PowerScope appliance armamentarium consisting of telescopic push rods (right and left), hexagonal screwdriver, and crimpable shims

Appliance design

PowerScope is delivered as a one size fits all appliances preassembled with attachment nuts for quick and easy chairside application.[9] The appliance allows intermaxillary wire-to-wire installation using a nut with hexagonal screw. Ball and socket joint to maximize the lateral movements improving patient comfort. The appliance consists of a telescopic mechanism consisting of inner shaft/push rod, middle and outer tubing, between middle tubing and outer tubing. There is a nickel-titanium (NiTi) spring delivering constant 260 g force.[9] This appliance delivers unmatched patient comfort, eliminates the need for headgear tubes or special band assemblies, and can be used with either banded or bonded molar tubes.

Appliance insertion

Unlike other Class II correctors, there was no need for assembly, taking measurements or appliance manipulation. The appliance allows wire-to-wire installation with attachments placed mesial to the first molar in the maxillary arch and distal to the canine of the mandibular arch generating a horizontal directed force [Figure 2]. This could also yield a slight intrusive force component to maxillary molars.
Figure 2

PowerScope insertion

PowerScope insertion

Appliance activation

Activation dot marking for visual reference is provided at the push rods of the appliance (right and left) as shown in the diagram which helps us to determine if the appliance is activated or not. If the dot mark is exposed, it indicates the appliance is inactive and to reactivate the appliance crimpable shims are added to the shaft.

Case Report

A 13-year-old female presented with a chief complaint of forwardly placed upper front teeth. Clinical examination revealed convex profile with posterior divergence, recessive chin, lip incompetence, and protrusion of the upper lip [Figure 3a and b]. The patient presented a Class II, Division 1 malocclusion with an overjet of 9 mm and an overbite of 6 mm.
Figure 3

(a and b) Pretreatment extraoral photographs

(a and b) Pretreatment extraoral photographs Cephalometric analysis revealed a convex skeletal profile with ANB angle of 7°, a severely retruded mandible, and a well-positioned maxilla [Figure 4a and Table 1]. Dentoalveolar readings suggested proclined upper anterior teeth with mild retroclination of mandibular incisors. The mandibular plane angle was normal, suggesting an average growth pattern. Hand-wrist X-rays indicated that the patient's growth was not completed.
Figure 4

(a-c) Pretreatment, leveling and aligning, and posttreatment lateral cephalogram

Table 1

Skeletal changes in sagittal plane at pre-treatment, Leveling & Aligning and post-treatment

(a-c) Pretreatment, leveling and aligning, and posttreatment lateral cephalogram Skeletal changes in sagittal plane at pre-treatment, Leveling & Aligning and post-treatment

Treatment objectives

Obtain asymmetrical Class I occlusion ruling out extractions Improve facial profile by accentuating mandibular growth Restrict maxillary growth in sagittal and vertical plane Avoid any undue backward rotation of the mandible.

Treatment plan

A nonextraction approach was planned using MBT 0.022” slot preadjusted appliance. After leveling and aligning, PowerScope was chosen to advance the mandible into a Class I relationship followed by finishing and detailing.

Treatment progress

Treatment was started using 0.014” NiTi in both arches. Leveling and alignment was completed in 7 month time period and 0.019” × 0.025” stainless steel wire was placed in both the arches. This was followed by mandibular advancement using PowerScope appliance [Figure 5a–f].
Figure 5

(a-f) Before and after PowerScope insertion

(a-f) Before and after PowerScope insertion A 5° labial root torque was given in mandibular archwire to prevent the flaring of the lower anterior. A substantial improvement in the patients profile was noted after the mandibular advancement. Since the appliance was anchored onto the orthodontic wire, no debonding of lower canine bracket/upper buccal tube was observed during the treatment with PowerScope appliance. Overall treatment was uneventful.

Discussion

Among all malocclusion, Class II malocclusion presents a constant challenge to the orthodontists.[10] Many treatment approaches and various appliances have been endeavored for correcting the Class II malocclusion which can be as a result of skeletal abnormalities. Class II malocclusions due to mandibular retrusion are most commonly treated with functional orthodontic appliances. A functional appliance creates orthopedic force directed at the mandibular condyle. These appliances produce skeletal correction by initiating remodeling changes at the mandibular condyle and glenoid fossa as well as, repositioning the mandibular condyle in the glenoid fossa and autorotation of the mandibular bone.[11] They can be of two types – removable or fixed appliances. Among fixed functional appliance, PowerScope has been added to the inventory recently by American Orthodontics. Literature is abundant with studies on many fixed functional appliances such as Jasper jumper, Herbst, Universal bite jumper, Eureka Spring, and Forsus FRD, but no reports are currently available with regard to PowerScope.[12131415] The case discussed here was treated with PowerScope considering its advantage over the conventional ones. The PowerScope was a fixed one-piece appliance available in one size suiting all Class II patients when compared to the ones used until now. One piece concept prevents the dislodgment of the appliance on various jaw movements. Moreover, the size selection, ordering the appliance, and delay in receiving the appliance could be all avoided as the appliance is unisized. Customization of the appliance could be done with the help of crimpable shims supplied along with PowerScope armamentarium. The appliance allows the quick and easy wire-to-wire installation preventing bond failures of bracket and buccal tube. The ball and socket joint at the two ends of the appliance allows excellent jaw movements reducing much of patient discomfort. This paper illustrates the skeletal, dental, and soft tissue changes after treatment with PowerScope fixed functional appliance. Moreover, we have attempted to enumerate the advantages of this appliance over the conventional ones based on our clinical experience. On comparing the cephalometric outcomes, a considerable improvement in skeletal, dental, and soft tissue parameters was observed at the end of PowerScope treatment [Figure 4a–c and Tables 1–3]. The entire period of treatment with PowerScope was uneventful. The posttreatment cephalometric measurements revealed favorable sagittal skeletal changes. No change in SNA angle (81°) was observed all throughout the treatment. A mandibular advancement was clearly evident as SNB angle increased from 74° to 79° and a 5° reduction in ANB angle and 4 mm advancement of BO in Wit's appraisal was observed. Beta angle increased by 3° (from 27° to 30°). There was an increase in Schwarz mandibular length by 3 mm (75–78 mm) after PowerScope correction [Table 1]. A mild increase in lower facial height within normal limits was noticed at the end of the treatment as shown in Table 2.
Table 3

Cephalometric assessment of dental and soft tissue pre-treatment Levelling & aligning and post-treatment

Table 2

Skeletal changes in vertical plane at pre-treatment, Leveling & Aligning and post treatment

Skeletal changes in vertical plane at pre-treatment, Leveling & Aligning and post treatment Cephalometric assessment of dental and soft tissue pre-treatment Levelling & aligning and post-treatment The maxillary incisors angulation remained unchanged whereas mandibular incisors proclined by 2 mm linear and 4° angular after PowerScope correction [Table 3]. The slight proclination at the end of the treatment could be attributed to the force concentrated in the lower anterior segment during fixed functional appliance treatment. However, the use of MBT brackets (−6° torque in the lower incisor), molar to molar consolidation in both arches, cinching off the lower archwire, and use of pretorqued wire before insertion of the PowerScope has helped us to counteract the protrusive effect on mandibular incisors. A near to normal interincisal angle was established. A substantial improvement in soft tissue was appreciated with a tendency toward an orthognathic profile [Figure 6a–e]. The lower lip relation to E line improved greatly from −2 mm to −1 mm. Upper lip to E line along with nasolabial angle also showed substantial improvement. The treatment could thus accomplish a well-balanced face with a pleasant smile which could be well ascertained from the superimposition of soft tissue and hard tissue [Figures 6a, b, and 7a–c]. The results were stable and extremely satisfying for both the clinician as well as the patients.
Figure 6

(a-e) Posttreatment extraoral and intraoral photographs after mandibular advancement with PowerScope

Figure 7

(a-c) Hard tissue and soft tissue superimposition

(a-e) Posttreatment extraoral and intraoral photographs after mandibular advancement with PowerScope (a-c) Hard tissue and soft tissue superimposition The advantages of PowerScope appliance as per our experience could be enumerated as follows: Fixed one-piece appliance available in one size suiting all Class II patients Require no laboratory setup Quick and easy wire-to-wire installation Compliance free Internal NiTi spring delivers 260 g of force for continuous activation during treatment No headgear tube or special band assemblies required Can be used with banded or bonded molar tube No bond failure of canine bracket or buccal tube Low profile and less bulky for more esthetic facial appearance Smooth, rounded patient-friendly design for better patient comfort Easy to clean – better oral hygiene Ball and socket joint allowing maximum lateral movement Telescopic device that does not displace or disengage during treatment.

Conclusion

Extraction correction of Class II malocclusion due to functional mandibular retrusion should be avoided as it can lead to detrimental changes in the soft tissue profile of the patient. Such patients will be very well benefited by treatment using Class II correctors such as PowerScope. Excellent results can be achieved by limiting the side effects, minimizing the need for patient compliance, and avoiding appliance breakage. PowerScope could be one of the best treatment options for Class II correction, especially in noncompliant patients with a drastic improvement in the soft tissue profile and esthetic appearance of the patient by the sagittal forward displacement of mandible ensuring excellent long-term stable results.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  12 in total

1.  Fixed functional appliances--a classification.

Authors:  A K Ritto; A P Ferreira
Journal:  Funct Orthod       Date:  2000

2.  Class II correction in patients treated with class II elastics and with fixed functional appliances: a comparative study.

Authors:  B Nelson; K Hansen; U Hägg
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-08       Impact factor: 2.650

3.  Cephalometric determinants of successful functional appliance therapy.

Authors:  H P Patel; H C Moseley; J H Noar
Journal:  Angle Orthod       Date:  2002-10       Impact factor: 2.079

4.  The Forsus Fatigue Resistant Device.

Authors:  William Vogt
Journal:  J Clin Orthod       Date:  2006-06

Review 5.  Mandibular changes produced by functional appliances in Class II malocclusion: a systematic review.

Authors:  Paola Cozza; Tiziano Baccetti; Lorenzo Franchi; Laura De Toffol; James A McNamara
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

6.  Force-deflection characteristics of the fatigue-resistant device spring: an in vitro study.

Authors:  Moaaz Mohamed El-Sheikh; Keith Godfrey; Montein Manosudprasit; Nita Viwattanatipa
Journal:  World J Orthod       Date:  2007

7.  "Effective condylar growth" and chin position changes in Herbst treatment: a cephalometric roentgenographic long-term study.

Authors:  H Pancherz; S Ruf; P Kohlhas
Journal:  Am J Orthod Dentofacial Orthop       Date:  1998-10       Impact factor: 2.650

8.  Mandibular changes during functional appliance treatment.

Authors:  C Nelson; M Harkness; P Herbison
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-08       Impact factor: 2.650

9.  Nonextraction treatment.

Authors:  N M Cetlin; A Ten Hoeve
Journal:  J Clin Orthod       Date:  1983-06

10.  Clinical application and effects of the Forsus spring. A study of a new Herbst hybrid.

Authors:  N Heinig; G Göz
Journal:  J Orofac Orthop       Date:  2001-11       Impact factor: 1.938

View more
  6 in total

1.  A Custom Made Skeletal Class II Corrector Appliance in Late Adolescent Phase.

Authors:  Navneet Singh; Tulika Tripathi; Priyank Rai; Shilpa Kalra
Journal:  J Clin Diagn Res       Date:  2017-04-01

2.  Wnt/β-catenin signaling pathway is activated in the progress of mandibular condylar cartilage degeneration and subchondral bone loss induced by overloaded functional orthopedic force (OFOF).

Authors:  Zijing He; Meixi Liu; Qiang Zhang; Yihong Tian; Lingzhi Wang; Xiao Yan; Dapeng Ren; Xiao Yuan
Journal:  Heliyon       Date:  2022-10-01

3.  The Class II Carriere Motion appliance.

Authors:  Daniel Areepong; Ki Beom Kim; Donald R Oliver; Hiroshi Ueno
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

4.  The Evaluation and Clinical Efficiency of Power Scope: An Original Research.

Authors:  Tony Antony; Vivek Amin; Shourya Hegde; Shreya Hegde; Deepa Shetty; Mohammadi Begum Khan
Journal:  J Int Soc Prev Community Dent       Date:  2018-05-17

5.  Management of Asymmetric Mandibular Retrognathia with Differential Loading Technique: A Case Report.

Authors:  Ajit V Parihar; Kavin Prasanth Angamuthu; Rojalin Sahoo; Shivam Verma
Journal:  Int J Clin Pediatr Dent       Date:  2021

6.  Airway changes in patients with sleep apnea using AdvanSync2 Class II correctors - a case series.

Authors:  Pasupureddi Keerthana; Gunjan Negi; Prasad Chitra
Journal:  Med Pharm Rep       Date:  2022-07-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.